![Badger Meter Blancett B114-110 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/badger-meter/blancett-b114-110/blancett-b114-110_user-manual_3053283004.webp)
Specifications
SPECIFICATIONS
Materials of
Construction
Body
316 stainless steel
Rotor
CD4MCU stainless steel
Rotor Shaft
Tungsten carbide
Rotor Support
316 stainless steel
Operating
Temperature
–150…350° F (–101…177° C)
Pressure Rating*
800 or 5000 psi
End Connections
NPT, BSP, Victaulic®, flange, hose barbed
Turndown Ratio
10:1
Accuracy
±1% of reading for 7/8 in . and larger meters
±1% of reading over the upper 70% of the measuring range for 3/8, 1/2, and 3/4 in . meters
Repeatability
±0 .1%
Calibration
Water (NIST traceable calibration)
Pickup
PN:
Description:
Body Thread:
Termination Type:
Mounthing Thread Electrical:
Output:
Resistance:
Gauss:
Temperature Range:
Pinouts:
B111109
Standard Magnetic Pickup; -150…330° F (-101…165° C)
5/8-18 UNF
2-Pin MS
MS3106-10SL-4S
MAG (mV Freq)
1500 Ω ± 10%
~1200
-150…330° F (-101…165° C)
A=Coil, B=Coil (no polarity)
* Consult factory for pressure ratings for flanged meters .
** Consult factory for ordering options
INSTALLATION
PRESSURE IN EXCESS OF ALLOWABLE RATING MAY CAUSE THE HOUSING TO BURST AND CAUSE SERIOUS
PERSONAL INJURY.
AVERTISSEMENT
LA PRESSION AU-DESSUS DE L’ESTIMATION PERMISE PEUT FAIRE ÉCLATER ET CAUSER LE LOGEMENT LE DOMMAGE
CORPOREL SÉRIEUX.
1 . Check the internals of the flow meter for any foreign material . Make sure the turbine rotor spins freely prior to installation .
Also, check fluid lines and remove any debris found .
2 . Install the flow meter with the flow arrow, etched on the exterior of the meter body, pointing in the direction of fluid flow .
Though the meter is designed to function in any position, where possible, install it horizontally with the conduit adapter
facing upward .
3 . Thread a magnetic pickup (Badger Meter model B111109 or equivalent) into the conduit adapter completely finger tight
without forcing . Secure with a lock nut if supplied .
4 . Install conduit or other fittings suitable for the installation area onto the conduit adapter hub on the flow meter .
Page 4
November 2022
TUR-UM-00014-EN-09
www.calcert.com
1.888.610.7664
0
5
10
15
20
25
30