background image

Scope of This Manual

Page 3 

April 2016

TRB-UM-00372-EN-03

SCOPE OF THIS MANUAL

This manual is intended to help you get the QuikSert turbine flow meter up and running 

quickly�

MPORTANT

I

Read this manual carefully before attempting any installation or operation. Keep the manual 

accessible for future reference. 

UNPACKING AND INSPECTION

Upon opening the shipping container, visually inspect the product and applicable 

accessories for any physical damage such as scratches, loose or broken parts, or any other 

sign of damage that may have occurred during shipment�

OTEE:

N

If damage is found, request an inspection by the carrier’s agent within 48 hours of 

delivery and file a claim with the carrier� A claim for equipment damage in transit 

is the sole responsibility of the purchaser�

SAFETY

Terminology and Symbols

 

Indicates a hazardous situation, which, if not avoided, is estimated to 

be capable of causing death or serious personal injury�

 

Indicates a hazardous situation, which, if not avoided, could result in 

severe personal injury or death�

 

Indicates a hazardous situation, which, if not avoided, is estimated to 

be capable of causing minor or moderate personal injury or damage 

to property� 

MPORTANT

I

Not following instructions properly may impair safety of equipment and/or personnel.

INTRODUCTION

The QuikSert Standard turbine flow meter was developed for liquid applications where 

accuracy and dependability are of concern to the operator� The stainless steel body 

incorporates a helical turbine with tungsten carbide shaft and bearings� It provides an 

efficient, long service life and a cost-effective solution for your measurement requirements�

Simple in design and construction, QuikSert uses modified upstream and downstream flow 

straighteners for a high degree of flow accuracy� Its between-the-flange design eliminates 

the need for mating flanges, requiring less space in the flow line, lowering costs and 

providing easy, one-person installation�

The meter produces a sine wave signal proportional to its volumetric flow rate� With 

optional Blancett electronics, QuikSert provides local flow rate and volume totalization and 

will interface with most instruments, PLCs and computers�

Содержание B131-038

Страница 1: ...Turbine Flow Meter QuikSert Standard TRB UM 00372 EN 03 April 2016 User Manual...

Страница 2: ...ols 3 Introduction 3 Operating Principle 4 Installation 4 Operational Startup 6 Calibration 6 Troubleshooting Guide 7 Part Number Information 8 Strainer Recommendations 8 Repair Kit Information 9 Spec...

Страница 3: ...could result in severe personal injury or death Indicates a hazardous situation which if not avoided is estimated to be capable of causing minor or moderate personal injury or damage to property IMPOR...

Страница 4: ...flow meter internally for foreign material and make sure the turbine rotor spins freely prior to installation 2 Check fluid lines and clear any debris 3 Install the flow meter with the flow arrow etc...

Страница 5: ...the flow meter or meter accuracy may be affected Piping should be the same size as the meter bore or threaded port size Do not install the flow meter or connection cable close to electric motors trans...

Страница 6: ...3 Open the upstream isolating valve slowly to eliminate hydraulic shock while charging the meter with the liquid 4 Open the valve to full open 5 Open the downstream isolating valve to permit meter to...

Страница 7: ...tor shows flow when shut off Mechanical vibration causes rotor to oscillate without turning Isolate meter No flow indication Full or partial open position Fluid shock full flow into dry meter or impac...

Страница 8: ...132 250 2 in 3 in 50 8 mm 76 2 mm 40 400 1300 13 000 218 2180 B133 300 3 in 3 in 76 2 mm 76 2 mm 60 600 2100 21 000 327 3270 B134 400 4 in 4 in 101 6 mm 101 6 mm 100 1200 3400 41 000 545 6540 B136 600...

Страница 9: ...psi 3 62 in 2 5 in 91 9 mm 63 5 mm B132 075 B253 208 18 psi 3 62 in 2 5 in 91 9 mm 63 5 mm B132 088 B253 209 20 psi 3 62 in 2 5 in 91 9 mm 63 5 mm B132 100 B253 212 20 psi 3 62 in 2 5 in 91 9 mm 63 5...

Страница 10: ...705 Working Pressure MPa 1 97 5 1 10 2 15 31 25 55 Test Pressure psi 427 5 1110 2220 3330 5557 5 Test Pressure MPa 2 95 7 65 15 31 22 96 38 32 Test pressure based on 1 5 safety factor Accuracy 1 0 of...

Страница 11: ...Specifications Page 11 April 2016 TRB UM 00372 EN 03 Figure 5 Typical cross section of models B132 050 B139 900...

Страница 12: ...C V Pedro Luis Ogaz n N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Middle East and Africa Badger Meter Europa GmbH Nurtinger Str 76 72639 Neuffen Germa...

Отзывы: