FLOW SENSOO INSTALLATION
DEPRESSURIZE AND VENT PIPING SYSTEM PRIOR TO ANY INSTALLATION OR MAINTENANCE OF THE FLOW SENSOR.
DISCONNECT POWER FROM FLOW SENSOR SOURCE AND/OR RECEIVING DEVICE PRIOR TO ANY INSTALLATION OR
MAINTENANCE OF THE SYSTEM.
1 Remove the sensor assembly and the nut from the tee
2 Remove burrs from the pipe ends and remove dirt and loose debris from pipe and tee sockets
3 Glue the line pipe into the tee using an appropriate primer and cement according to the manufacturer's instructions Do
not use or leave excess glue Glue build-up in the tee can affect the measurement performance of the unit and/or prevent
the impeller from turning Do not let the glue or primer contact the bore where the O-rings seal
4 Insert the sensor into the tee, carefully lining up the locating hole in the sensor with the locating pin in the tee
5 Install and hand-tighten the retaining nut
6 Complete the wiring connections See
"Electrical Installation Guidelines" on page 5
for details
7 Complete the wiring connections
Flow Sensor Installation
Page 6
October 2015
SEN-UM-01665-EN-04