Programming of LM OG (CND) and LM OG-HF (CND)
Page
12/27
LM_OG_BA_98_1803
Press 3 times „Total“ and
3 times „Reset“ (quickly) to
access the programmation
mode. Measuring unit “L”
(liter) is flashing and can
be changed in L, GAL, QT
or PT when pressing
“Reset”. Press “Total” to
confirm the new
measuring unit.
Programming of LM OG (CND) and LM OG-HF (CND)
Press „Total“ one time to
switch on the meter.
Press both buttons
simultaneously to save the
programmation.
The meter then goes to the
sleeping mode.
The fifth figure can now
be changed.
The fourth figure can now
be changed.
To access the next figure,
press “Total”.
Press “Total” one time
to change the k-factor.
The figure to be
changed is flashing
and can be modified
with “Reset”.
To change the next
figure, press “Total”.
The second figure can
now be changed.
To access the next figure,
press “Total”.
The third figure can now
be changed.
To access the next figure,
press “Total”.
After the sleeping mode,
please press „Total“ to
show the „normal“
display mode.
Sleeping mode
Press „Reset“ during 3
seconds and the
register displays the
check sum.
„Total“ resettable
(Keep „total“ pressed, then
press „reset“)
„Total“ not resettable
Measuring unit