SCALE ACS-Z
USER MANUAL
VERSIÓN 12.11.06
Страница 1: ...SCALE ACS Z USER MANUAL VERSI N 12 11 06...
Страница 2: ...4 Tare Function Pag 4 Zero Function Pag 4 Setting Alarm Function Pag 4 Counting mode Pag 5 Percentum mode Pag 5 Calibration Pag 6 ALARM INDICATION Pag 6 RS232 TRANSMISSION METHOD Pag 7 RS232 setting...
Страница 3: ...Relative humidity 85 RH 2 KEYBOARD INSTRUCTION To Calibrate the scale when the scale is moved to a different place To choose different function model Weighing Counting percentum To choose different un...
Страница 4: ...ow displays Zero The Tare signal disappear Zero Function You may press Zero to make display zero when the zero moved when in use Zero range 4 FS it is invalid under tare state Setting Alarm Function 1...
Страница 5: ...ate The signal will disappear after about 3 seconds b When the weight window displays CSL it means the unit weight of sample is not enough at all Please press Set to re sample Press Enter to exit back...
Страница 6: ...pressing cannot be more than the full scale 4 ALARM INDICATION 1 The weight window displays OF with continuously alarm sound when the weight over 100 FS 9d If the ADC overflows the weight window disp...
Страница 7: ...Press the set key to choose the method of Stb output when stable Etb output once when Enter key is pressed SEr series continuous output or CLOSE output disabled Then press key to select method or pre...
Страница 8: ...bit Bit10 stop bit 5 2 2 Data format Every message include 6 bytes they are following No 1 D0 D7 0FFH Message Flag No 2 D0 D2 Decimal point 0 5 D3 D4 Current mode 00 weighting 01 counting 10 percentu...