Checking for Leaks
Burner Connections
1. Make sure the regulator hose and valve connections are securely fastened to the burner
and the tank.
2. Visually check the connection between the burner/venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the orifice.
W
WARNING: Failure to inspect this connection or follow these
instructions could cause a fire or an explosion which can cause death,
serious bodily injury or damage to property.
4. Please refer to diagram for proper installation (Figures 1, 2 and 4).
5. If the burner/venturi tube does not rest flush to the orifice, as shown, please contact 0800
9520101 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing soap with
three parts water.
2. Make sure control knobs are in the
•
(OFF) position (Figure 3).
3. Connect gas tank per “Installing Gas Cylinder” section.
4. To turn regulator ON, turn the regulator valve counterclockwise into the the “ON” position.
(Figure D)
5. Spoon several drops of solution, or use a squirt bottle, at all “X” locations (Figures 1, 2 and
4).
a. If any bubbles appear, turn the regulator valve clockwise into the the “OFF” position.
(Figure C).
b. If you continue to see bubbles after several attempts, turn gas cylinder valve to “OFF”
and disconnect gas cylinder, per “Disconnect Gas Cylinder” section. Contact 0800
9520101 for assistance.
c. If no bubbles appear after one minute, turn gas cylinder valve to “CLOSED,” wipe away
solution and proceed.
Operating Main Burners
First Use
1. Make sure all labels, packaging and protective films have been removed from the grill.
2. Remove manufacturing oils before cooking on this grill for the first time by operating
the grill for at least 15 minutes on (HIGH) with the lid closed. This will “heat clean” the
internal parts and dissipate odors.
Lighting
W
CAUTION: Keep outdoor gas cooking appliance area clear and free
from combustible materials, gasoline and other flammable vapors and
liquids.
W
CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W
CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
W
CAUTION: Attempting to light the burner with the lid closed may cause
an explosion.
1. Open lid.
2. Check for obstructions of airflow to the burners. Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube can lead to a fire.
3. All control knobs must be in the
•
(OFF) position (Figure 3).
4. Connect gas cylinder per “Installing Gas cylinder” section.
5. To turn regulator ON, turn the regulator valve counterclockwise into the the “ON” position.
(Figure D).
6. Push and turn any control knob to (HIGH). The burner should light. If it does not, repeat up
to three times.
Operating Instructions
Figure 1: Main Burners
Burner/venturi tube
LP Gas Valve with Orifice
LP Gas
Connection
Figure 2: Side Burner
LP Gas
Connection
LP Gas
Valve with
Orifice
Burner/venturi tube
Figure 3
Figure 4
X
X
X
X
X
Figure 5
Match
Lighting
hook