Once the fire product is lit, the fame intensity may be controlled by turning the control knob (F)
counterclockwise to the
'
LOW
'
position will ignite the fuel.
OPERATION
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the
'OFF'
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak.
If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable).
Pumice stones/lava rocks/LavaGlass
®
could pop up and
strike somebody’s face during the
20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches in height.
Wait 50 minutes after extinguishing flame prior to placing a lid (if applicable) or protective cover on
heating item.
To Light
To Extinguish
1. Make sure the control knob (F) is in the
'
OFF
'
position.
2. Open the door (E) and slowly open the valve on the propane gas tank by turning the knob
counterclockwise.
3. Close the door (E) on the body.
5. If ignition doesn’t occur within a few seconds release the control knob (F) and rotate to the
'
OFF
'
position. Wait for 5 minutes for gas to clear and then repeat the above lighting instructions.
6.
between the
'
LOW
'
and
'
HIGH
'
positions.
1. Turn control knob (F) clockwise to the
'
LOW
'
position; let the knob pop up and continue turning
the control knob (F) to the
'
OFF
'
position.
2. Close the cylinder valve on the propane gas tank if you don’t intend to use it for a long time.
4. A pulse igniter is built into the control knob (F) so pushing and truning the control knob (F)
for 15 seconds.
Keep holding down the control knob
WARNING
If the burner does not ignite with the burner
control valve open, gas will continue to flow
out of the burner and could accidentally ignite
causing injury or property damage.
OFF
H
L
OFF
H
L
in.
10
25
1
2.5
cm.
in.
cm.
in.
10
25
2
5
cm
in.
cm
Page 9