VENTILATION
When putting a TE cooler, ventilation should be considered seriously, please refer
to the following:
1, there should be left at least 200 cm3for ventilation
2, the distance between wall and cooler side should be at least 20mm
3, the bottom should be left at least 50mm for air flowing
4, air passing through must not be preheated
5, entire cooling system should be considered in the ventilation
TROUBLE SHOOTING GUILDS
Failure: no cooling
Possible reason
Action
No power
PCB broken
Fan broken
Leakage
Cooling module broken
Replace a new PCB
Replace a new fan
Replace a new heat pump
Replace a new cooling module with silicone
Check the electricity supply, or change a new plug
Possible reason
Action
Possible reason
Action
High ambient temperature
Poor instruction
Poor ventilation
Poor gasket
Poor silicone
The room temperature is hotter than normal
The door is opened too often
Replace a new door gaske
Install cooler according to our ventilation instruction
Change the silicone on the surface of the cooling module
Failure: poor cooling performance
Failure: noisy
Dust
Fan broken
Poor heat pump
Replace a new heat pump
Cleanthedustfromthefan
Changetoanewfan