background image

WARRANTY

The Bacharach Tru Pointe

®

 Ultra is warranted for one year to be free of manufacturing defects 

adversely affecting performance.  Should an instrument fail within the one year warranty period, 
the unit will be repaired or replaced provided in the opinion of the factory, the instrument has not 
been tampered with or abused. 

If defective, return to the factory for repair and re-calibration.  Maximum liability of Bacharach 
shall be limited to replacement of unsatisfactory product.

Recommendations and product information are believed to be accurate, but the furnishing of it 
does not constitute the making of a good process warranty of Seller.

Bacharach warrants that this product conforms to the Product Description contained in this 
literature.  

Bacharach makes no other warranty, whether expressed or implied, including 

warranties of merchantability or of fi tness for a particular purpose or application.

  No 

statements or recommendations contained herein are to be construed as inducements to infringe 
any relevant patent, now or hereafter in existence.  Bacharach neither assumes nor authorizes 
any representatives or other person to assume for it any obligation of liability other than such as 
expressly set forth herein.

Under no circumstances shall Bacharach be liable for incidental, consequential or other 
damages from any alleged negligence, breach of warranty, strict liability or any other 
theory, arising out of the use or handling of this product.

Contents

1 About 

This 

Manual..................................................................... 1

Warning Statements ................................................................... 1
Caution Statements .................................................................... 1

2 Introduction 

................................................................................ 2

General Description.................................................................... 2
What’s in the Kit ......................................................................... 2
28-8000 ...................................................................................... 2
28-8010 ...................................................................................... 2
Features ..................................................................................... 2

3 Speci

fi

 cations ............................................................................ 3

4 Operation 

................................................................................... 4

Physical ...................................................................................... 4
Taking Readings ......................................................................... 4
General....................................................................................... 4
Airborne Leak Detection ............................................................. 5
Electrical Arcing .......................................................................... 6
Electrical Corona ........................................................................ 6
Operating Tips ............................................................................ 6
Using the Touch Probe ............................................................... 7
Thermal Expansion Valves (TXV) .............................................. 7
Using the SoundBlaster

® .......................................................................................................

8

Care and Service ....................................................................... 9

Cleaning ..................................................................................... 9
Battery Replacement .................................................................. 9
Service ....................................................................................... 9

Содержание Tru Pointe Ultra

Страница 1: ...Tru Pointe Ultra Ultrasonic Leak Detector Instruction 28 9000 Operation and Maintenance Rev 0 May 2010 The Measurable Difference ...

Страница 2: ...itness for a particular purpose or application No statements or recommendations contained herein are to be construed as inducements to infringe any relevant patent now or hereafter in existence Bacharach neither assumes nor authorizes any representatives or other person to assume for it any obligation of liability other than such as expressly set forth herein Under no circumstances shall Bacharach...

Страница 3: ...the warning symbol at left in this manual denotes a potential hazard associ ated with the use of this equipment It calls attention to a procedure practice or condition or the like which if not correctly performed or adhered to could result in personal injury or death Caution Statements The use of the word CAUTION and the caution symbol at left in this manual denotes a potential hazard associ ated ...

Страница 4: ...3 Folding Hi Fi Headset w Volume Control 28 0002 9v Battery 204 0024 Warranty Card 06 8825 3 Specifications Physical Dimensions 4 15 L X 2 4 W X 875 D 105 mm X 61 mm X 22 22 mm Overall Length 5 5 140 mm Body Material ABS Body Finish Blue ABS Connector 3 5 mm Stereo Weight 0 3 lb 138 g including battery Electrical Sensitivity 80 db V μbar Detection Performance 1 5oz year refrigerant Ultrasound Conv...

Страница 5: ... vacuum into a system The sound made by leaks refrigerant compressed air tire leak etc is mostly ultrasonic and cannot be heard by humans The following describes how to effectively determine the location of an airborne leak using the Tru Pointe Ultra 1 Press the On Off Button If there is significant background noise and the LED Bargraph Display reads 10 reduce the sensitivity until the LED s disap...

Страница 6: ...n a tight or inaccessible area use the supplied 1 4 tubing to deter mine the leak location Longer sections of 1 4 tubing can be used at the expense of sensitivity 3 Use as much pressure in the system as is safely possible to facilitate locating the leak Using the Touch Probe The patented Touch Probe accessory is a device that converts solid borne sounds into airborne sound the Tru Pointe Ultra can...

Страница 7: ...ce 800 736 4666 or 724 334 5000 to obtain an RMA number for service returns When you receive your RMA number return the instrument postage paid and insured to Bacharach Inc 9227 E Lincoln Ave Suite 200 Lone Tree CO 80124 USA Email help mybacharach com Using the SoundBlaster Some Tru Pointe Ultra kits include Bacharach s ultrasonic sound generator the SoundBlaster The SoundBlaster is used to artifi...

Страница 8: ...Tru Pointe Ultra Instruction 28 9000 10 11 Tru Pointe Ultra Instruction 28 9000 NOTES NOTES ...

Страница 9: ...Bacharach Inc Phone 724 334 5000 Toll Free 800 736 4666 Fax 724 334 5001 www mybacharach com help mybacharach com The Measurable Difference ...

Отзывы: