GDX-150 Sensor Transmitter
3. Specifications
Category
Description
Product Type
GDX-150 transmitter for low level continuous monitoring of ammonia in
ambient environments
Coverage
Single sensor, 40-foot diameter
Detector Type
Electro-chemical, field replaceable
Sensitivity
1 ppm
Measuring Range
0-500 ppm
Accuracy
±15% of full scale, ±1 count (whichever is greater) of reading from 0-500 ppm
Long term Drift
<10% per 6 months
Linearity
<10% of full scale
Temperature Drift
<0.1% per degree C over temperature range
Housing
316 stainless, suitable for Class 1, Div 1 and 2, Gr. B, C, D
¾ inch NPT threading
Calibration
Through GDA-400 or GDA-1600 controllers
Response Time
T
50
<30 s , T
90
<90s
4-20 output Signal
2-wire, 4-20 mA current sink. Max output = 25 mA
Operating Temp
-20 – 50 °C (-4 - 122 °F)
Ambient Humidity
5% to 90% RH (non-condensing)
Power
9 – 36 VDC, 250 mA (@ 24 VDC)
Certification
Intrinsically safe with use of an IS barrier
Warranty
2 years from date of shipment, consumables not included
4. Accessories and Replacement Parts
Part Number
Description
5600-0004
Calibration Cup/Sample Draw Adaptor
5600-0003
Splash Guard/Remote Cal-Cup
0024-7059
Calibration Kit – Regulator, Tubing and Carrying Case (no gas included)
0051-3160
NH
3
Calibration Gas, 25 ppm, 58 Liter
0051-7131
Zero Grade Air, 103 Liter
5600-5003
NH
3
Replacement Sensor
Headquarters:
621 Hunt Valley Circle, New Kensington, PA 15068-7074
Toll Free: 800-736-4666 • Tel: +1-724-334-5000 • FAX: +1-724-334-5001
Website: www.MyBacharach.com • E-mail: [email protected]
2
P/N: 5600-9000 Rev 2