Refrigerant Recovery Unit
14
2020-9000 Rev 0
ATTENTION:
Use an in-line filter when recovering liquid. Contaminants
(particularly from the bottom of recovery cylinders) can enter the ECO-
2020 and become lodged in the valve seats causing damage and
resulting in leaks. We recommend using Bacharach in-line filter
P/N 2020-0001 for optimum recovery speed.
IMPORTANT:
Make all hose connections as shown in Figure 7.
Ensure that all connections are correct and secure.
IMPORTANT:
Ensure all valves are CLOSED and ensure the filter
screen is clean.
Step
Description (Recovery Mode – Liquid or Vapor)
1
Switch off power to the refrigerant equipment and connect power
to the ECO-2020.
2
Turn the control knob to the START position.
3
Open the vapor and/or liquid valves of the refrigerant equipment.
4
Open the vapor valve of the recovery tank.
5
Turn on the power switch.
6
Press the start button.
7
Slowly turn the control knob to the RECOVER position.
8
When recovery is finished, the low pressure switch will activate, the
motor will shut off, and the green “Complete” LED will come on.
9
Purge the unit (refer to section 2.6 on page 16).
IMPORTANT:
If compressor knocking occurs when the control knob
is in the RECOVER position, slowly turn the control knob toward the
START position until the knocking stops.
www.calcert.com
1.888.610.7664
0
5
10
15
20
25
30