Thank you for purchasing Nasal Aspirator BabySmile S-502. To obtain the best performance 
and ensure continued safety, please read entire this user's manual. This user's manual also 
serves as a warranty certificate. Please keep this user's manual on file as it is required for 
covered repairs.

Before Using the Unit

Getting Started

Maintenance and Storage

Troubleshooting / Warranty

Safety Precautions 

……………

2

Unit Features 

…………………

6

Package Contents 

……………

7

Illustration of Important Parts 

……

8

Set-Up 

…………………………

10

How to Operate the Unit

……

12

After Use 

………………………

15

Cleaning and Disinfecting the Unit 

17

Assembly and Storage 

………

22

Malfunction and Unit Check-ups 

25

Specifications 

…………………

34

Warranty Provisions and Warranty 

35

Nasal Aspirator

S-502

User's Manual  

Ver. 1.0

Содержание S-502

Страница 1: ...t is required for covered repairs Before Using the Unit Getting Started Maintenance and Storage Troubleshooting Warranty Safety Precautions 2 Unit Features 6 Package Contents 7 Illustration of Importa...

Страница 2: ...not exceed 11 32 fl oz 335mL canister capacity Over ow of suctioned material from the canister into the pump may cause a malfunction Please consult with a physician or other healthcare professional i...

Страница 3: ...e inside Do not drop or subject the unit to any strong impact Failure to do so may cause a breakage electric shock or malfunction Do not drop or hit the unit Do not use the canister if it is damaged c...

Страница 4: ...d regulations Failure to do so may cause environmental pollution Be aware not to over ll the canister with suctioned material when cleaning When suctioned materials from the canister penetrate into th...

Страница 5: ...ting Agents Warning Parts should be rinsed with water thoroughly and dried completely after cleaning sterilizing and disinfecting They should be stored in a clean place Failure to do so may cause mult...

Страница 6: ...e Line of canister Note Be sure to keep the oat clean If suctioned materials are attached to the oat wash o immediately Removing the canister Diagram of Float shut O Valve Float Cover The float is ins...

Страница 7: ...ts 1 Main Unit 3 Suction Tube 5 2 pcs of Silicon Tips small size 6 User s Manual Warranty Certi cate this user s manual 7 Comic Manual 2 AC adapter manufacturer speci ed 4 Silicone Tip Connector Befor...

Страница 8: ...onnector The connector to which the suction tube is attached Canister The canister that holds suctioned materials The MAX line White Line indicates the limit of canister capacity Front Vacuum Regulato...

Страница 9: ...observe and reduce the vibrating Rear Power Switch The switch that turns power ON and OFF Caution Label Product Label Canister Cover Sliding off the canister cover from the main unit the canister is...

Страница 10: ...onnect the suction tube to the suction tube connector Make sure that the vacuum regulator knob is in the 1 position Connect the tip connector to the other end of suction tube connected to the main uni...

Страница 11: ...er plug or cord with wet hands Do not take o the AC Adapter Plug part Caution When changing the vacuum pressure please be sure to remove the silicone tip from the nostril before changing Do not turn O...

Страница 12: ...nstruction clear glove is not worn in this user s manual Connect the silicone tip to the silicone tip connector After making sure that the vacuum regulator knob is in the 1 position and the LED on the...

Страница 13: ...with the silicone tip Note Do not suction more than 6 seconds Instead perform 3 to 5 seconds short suction for several times 5 6 Optimizing the suction power by turning the regulator knob Note When ap...

Страница 14: ...on the rear of the unit Caution Ensure all parts are dried thoroughly before assembly Penetrating water or any other liquid into the pump may cause a malfunction Note Make sure that all parts are com...

Страница 15: ...sition Unplug the AC adapter manufacture speci ed jack from the DC port of the main unit Make sure that the power switch is in the OFF position Unplug the power plug of AC adapter from the outlet Unpl...

Страница 16: ...materials Note Do not rotate the canister when connected to the main unit Failure to do so may cause suctioned materials and water in the canister penetrate into the main unit and may cause a malfunc...

Страница 17: ...he canister cover Before Cleaning and Disinfecting the Unit Cleaning and Disinfecting the Unit 1 2 Remove the float cover from the canister cover and take out the oat Note Do not lose the float The fl...

Страница 18: ...18 Remove the float shut off valve from the canister cover Remove the canister O Ring attached to the canister 4 5...

Страница 19: ...als do not exceed 11 32 oz 335mL canister capacity Immerse the suction tube in the liquid of diluted natural detergent with water Clean thoroughly inside the suction tube with the liquid and apply the...

Страница 20: ...fected parts should be rinsed with water and dried thoroughly and should be kept in the clean place Caution Do not use benzine thinner or other volatile agents to clean the unit Boiling disinfection c...

Страница 21: ...e tube parts 3 Wash o the disinfectant completely and rinse the parts thoroughly with water Note The disinfectant with sodium hypochlorite or benzalkonium chloride is highly corrosive Be sure to wash...

Страница 22: ...ch the oat cover to the canister cover Attach the oat shut o valve to the canister cover 2 1 Note Assemble and attach all the parts to the main unit before storing Assembly and Storage Attach the suct...

Страница 23: ...lean place 5 6 7 Warning Ensure that all parts are dried thoroughly before assembly Keep the unit out of reach of children and do not store it on the unstable location Caution Ensure that all parts ar...

Страница 24: ...rite Ethanol e g disinfection ethanol Silicone Tip Silicone Silicone Tip Connector PP Suction Tube Silicone Suction tube connector ABS Canister Cover ABS Canister PS Float Shut O Valve Natural Rubber...

Страница 25: ...the unit is over 1 500 hours The life cycle of motor is varied greatly according to the operation environment The normal life cycle of motor is 1 500 hours Please contact the store you purchased the...

Страница 26: ...Leakage Checklist Check Locations Possible Leakage Cause Things to Do Between the canister and canister cover The canister may have not been attached to the canister cover straight Place the canister...

Страница 27: ...attached to the canister cover correctly Attach the float shut off valve correctly to the canister cover Take it off disassemble and clean all parts if dirty Contact the store if lost Canister Check i...

Страница 28: ...ts if damaged Suction Tube Check if there is any crack scratch or damage Clean it if dirty Replace it if damaged Vacuum Regulator Knob Check if the suction power is controlled properly with the suctio...

Страница 29: ...ts All Requirements stated in IEC60601 1 are met Notice and Warning Read entire this user s manual and warranty provision before using WEEE Symbol for Separate Collection in European Countries This sy...

Страница 30: ...ed may result in increased EMISSIONS or decreased IMMUNITY of the ME EQUIPMENT Recommended separation distances between portable and mobile RF communications equipment and Nasal Aspirator BabySmile S...

Страница 31: ...le S 502 system should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000 4 6 3 Vrms 150 kHz...

Страница 32: ...commercial or hospital environment Surge IEC 61000 4 5 1 kV di erential mode 2 kV common mode N A Mains power quality should be that of a typical commercial or hospital environment Voltage dips short...

Страница 33: ...BabySmile S 502 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RE emissions CISPR11...

Страница 34: ...ospheric Pressure 70kPa 105kPa External Dimensions W 9 44inch x D 3 34inch x H 6 85inch W 240mm x D 85mm x H 174mm excluding protuberances Unit Weight Approx 2 75lbs 1 25kg excluding the AC Adapter Ac...

Страница 35: ...any type of natural disaster including re earthquake lightning wind and ood d When the malfunction or damage is caused by unauthorized repair or modi cation performed by the user e When the warranty...

Страница 36: ...ace the unit free of charge For the warranty covered repair please bring the copy of sales receipt and this user s manual as a proof of your purchase to the store you purchased the unit Distributed by...