Page 28
Baby Lock Tiara II Instruction Manual
Motor Speed Sensor Test
The “Speed” Sensor test can help you determine whether
or not there is a problem with the Baby Lock Tiara II
speed sensor. Before performing this test, remove the
bobbin case and the top thread. Press the foot pedal so
that the machine will begin slowly rotating. The white box
will show a number that should stabilize at 100 if the sen-
sor is functioning properly. Release the foot pedal to stop
the ma chine (Figure 38).
Press the “Main” button to return to the “Main” menu
screen or the “Back” button to return to the “More” menu
screen.
Pedal Test
The “Pedal” test can help you determine if there is a prob-
lem with the Baby Lock Tiara II foot pedal. As you slowly
depress the foot pedal a percent of depression will appear
in the white box. The foot pedal should be controllable
from 0 to 100% (Figure 39).
Press the “Main” button to return to the “Main” menu
screen or the “Back” button to return to the “More” menu
screen.
System Information Screen
The serial number of the machine is displayed at the top
of the System Information screen. This number matches
the one found on the label at back of machine..
Information contained in the white boxes below the serial
number identifies the electronics board version numbers
as well as the firmware version numbers of the Baby Lock
Tiara II and its handlebars.
The Lifetime and Trip (or project) stitch counters count
the number of stitches the machine has performed. The
Lifetime count is the total number of sewn stitches since
the machine was built. The Trip Counter can be reset to
keep track of the number of sewn stitches during a given
project. To reset this counter, press the blue “Reset” but-
ton found aligned with the Trip counter.
The Lifetime counter cannot be reset and should be used
as an indicator to determine when general machine main-
tenance should be performed by your authorized Baby
Lock retailer (Figure 40).
Press the “Main” button to return to the “Main” menu
screen or the “Back” button to return to the “More” menu
screen.
Figure 40
Solid beep for 1/3 of a stitch cycle,
no beep for the rest of the cycle.
Main
System Information
Back
Serial Number
Stitch Counters
Type
HA010553310
Board
Firmware
C-Pod
Display
2.02
1.00
3.04
2.00
Reset
Lifetime
Trip
000004361
000004361
Figure 39
Main
Diagnostics
Back
Foot Pedal Test
Value below varies from 0 to 100%.
Passing Test:
Remove bobbin case and top thread.
Clear all objects from the needle area.
Depress foot pedal completely.
45%
Main
Diagnostics
Back
Motor Speed Sensor Test
The value stabilizes at 100.
Passing Test:
Remove bobbin case and top thread.
Clear all objects from the needle area.
Press Start/Stop on Handle.
0
Figure 38