background image

Do not place the pump motor unit near fire or open flame.

Do not place the pump motor device or charging cable into liquids, such as water, gasoline, 
beverage, etc.

Do not charge product near fire or in an environment with a temperature over 45 °C.

Keep PE bags away from children, to avoid the hazard of suffocation.

Please charge the pump motor unit before using it for the first time.

Please clean and sterilise all components before use. Immediately wash after use and keep the 
parts dry. The pump motor unit and charging cable cannot be cleaned by water or sterilise.

Keep the product out of reach of infants.

Do not leave bottle tilted or overfilled when in use (do not exceed the maximum scale).

Please turn off the power when the pump control device is fully charged and when not in use.

When disassembling and cleaning, be careful not to lose any parts. During assembling, be sure to 
assemble each component according to the assembly sequence. Any missing component or 
improper assembly may cause the product to function abnormally or be unable to work. 

Adjust the suction level to suit your comfort level.

Please disassemble all components of the product before sterilisation. Do allow the product 
components to cool for about 20 minutes after the sterilisation is completed before assembling to 
avoid damage.

Please use the breast pump under the guidance of doctors, nurses or certified personnel.

Do not over pump as it may cause injury to the breast.

In case of any pain caused by the use of this product, please consult with a medical staff 
immediately.

A breast pump is a tool to help mothers in breastfeeding and should be used for the sole purpose 
of expressing breast milk. Some new mothers may face blocked mammary gland (which can be 
caused by congenital invaginated nipple), or insufficient milk supply. If faced with such problems, 
it is recommended to seek professional advice to verify that the mammary gland is unblocked. 

This product should only be used for the purpose described in this User’s Guide.

Any parts that are in direct contact with breast milk are personal care items and should not be 
shared with other users.

Expectant mothers should not be using a breast pump unless otherwise advised by a medical 
professional.

Precautions for use

Содержание be mine

Страница 1: ...User s Guide be mine Dual Electric Breast Pump baby express making parenting a breeze baby express Please read this user s guide carefully before using ...

Страница 2: ...ode The nasal suction mode can help suck out baby s thick mucus relieve or eliminate baby s nasal discomfort Frequency Adjustment With three adjustable frequency high medium and low Mothers can adjust the suction rhythm according to their comfort Single Dual Mode Selection Conveniently touch to switch between single or double expression mode giving you the feasibility to have the option to express...

Страница 3: ...lly or be unable to work Adjust the suction level to suit your comfort level Please disassemble all components of the product before sterilisation Do allow the product components to cool for about 20 minutes after the sterilisation is completed before assembling to avoid damage Please use the breast pump under the guidance of doctors nurses or certified personnel Do not over pump as it may cause i...

Страница 4: ... when cleaning the valve and the silicone diaphragm If it gets damaged the breast pump will not be able to operate Lithium battery usage precautions Dismantling impacting extruding or throwing into the fire are prohibited Do not put it under direct sunlight or in a hot environment Please do not use when there is any bulging Do not disassemble batteries Some components of lithium batteries are flam...

Страница 5: ...t before use If there is any missing part please contact the seller Silicone PP PP PP 2 2 2 PP PP Flange Cap No Material Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Food Grade Remark Quantity 20 C 120 C 20 C 130 C 20 C 120 C 20 C 100 C 20 C 200 C 20 C 200 C 20 C 200 C 20 C 200 C 20 C 200 C 20 C 200 C Temperature Component Name Diaphragm Chargi...

Страница 6: ...suction level for both sides is individually adjustable under the double suction function The default duration of expression mode is 28 minutes and for the bionic mode is 30 minutes Pause Button Touch the button to pause the breast pump second touch to resume working The unit will power off automatically after 3 minutes when left in pause mode Power Button Press and hold the power button to on the...

Страница 7: ...ress the rim to ensure a perfect seal Product assembling sequence Insert the valve on the cylinder under the T joint flange push it in until it fits tightly Attach the bottle into the bottom of the T joint flange until it s tightly joined If using single expression mode insert one silicone tube into the left air vent hole at the bottom of the pump motor unit Put on the pump cover Please remove the...

Страница 8: ...he suction gradually until you feel slight discomfort not a pain then slightly reduce the suction To end the session press the power button lightly to switch off the status light will automatically turn off Disassemble and clean all parts of the breast pump after use except for the motor adapter charging cable and silicone tube Nasal Aspiration Operations Press and hold button to change to Nasal S...

Страница 9: ...r a professional institute for more information and advice Breast milk will expand after freezing do not fill the feeding bottle or milk bag to the brim with milk please reserve at least 1 4 space for expansion Please indicate the milk pumping date time on the milk bottle or milk bag To minimise nutrition loss please thaw the frozen milk in the refrigerator compartment or put the milk bottle bag u...

Отзывы: