Installation, Operation & Maintenance

  

Lume-A-Lite™ EXIT SIGNS  

Model(s): BEM-SLE100/BEM-SE100 

 

 

 

 

o

 

Failure to supply the above minimum exposure can prevent the luminous egress-path-
marking from performing as intended. 

o

 

No specific building surface treatment is required for the luminous egress-path-marking 
system to function properly. 

o

 

Reliable external illumination is always required  during building occupancy. 

MAINTENANCE 

o

 

Maintain by cleaning as needed to prevent dirt, etc. from inhibiting the performance of the 

photoluminescent properties. 

o

 

The strip may be cleaned by using a damp cloth with mild, non-abrasive cleaners. Do not use 

highly alkaline or acidic cleaners. Rinse after applying cleaners and wipe with a clean cotton 

cloth to dry. 

Questions? 

For more information on installation, repair or replacement, please visit 

www.Babcockdavis.com

 or call 

(888) 412-3726 

 

Содержание Lume-A-Lite BEM-SLE100

Страница 1: ... to do so will affect product warranty Transportation Storage o Inspect all shipments and materials for missing or damaged components and hardware o Material must be stored in a clean dry location Preparation o These signs are for interior use only and are suitable for a temperature range of 50 to 100 degrees Fahrenheit o These signs are rated for a visibility of 100 feet when activated by a minim...

Страница 2: ... should then be confirmed as acceptable prior to the mounting bracket being fixed to the wall or ceiling o After installation is complete the visibility of the sign from all potential viewing angles and distances should be confirmed INSTALLATION One Sided Wall Mount Installation The photoluminescent exit sign shall be placed above doors through which occupants must pass to complete the exit path 1...

Страница 3: ...ng Mount One or Two Sided Installation The photoluminescent exit sign shall be placed above doors through which occupants must pass to complete the exit path 1 Mark pilot hole locations on ceiling using mounting holes in mounting bracket 2 Drill pilot holes in ceiling surface 3 Level and mount bracket to ceiling using mounting hardware 4 Slide and snap exit face plate to back plate 5 Attach top of...

Страница 4: ...ction properly o Reliable external illumination is always required during building occupancy MAINTENANCE o Maintain by cleaning as needed to prevent dirt etc from inhibiting the performance of the photoluminescent properties o The strip may be cleaned by using a damp cloth with mild non abrasive cleaners Do not use highly alkaline or acidic cleaners Rinse after applying cleaners and wipe with a cl...

Отзывы: