Section
6
Transmitter Specifications
6.1 Hazardous Locations /
General Ratings
6.3 Sensor Probe Specifications
CSA and CSAUS: Explosion Proof:
Class I Div. 1 or 2, Grps. B, C, D
Class II, Grps. E, F, G
Class III
T
amb
-40C to 85C (- 40F to 185F)
Housing:
Explosion proof, dual compartment,
½”npt conduit, epoxy coated
aluminum; NEMA 4X, 7
Humidity Limits:
SAMA PMC 31.1-5.2
Vibration Limits:
SAMA PMC 31.1-5.3
RFI Limits:
SAMA PMC 31.1-
20 to 1000 MHz
Up to 30 V/m
6.2 Electronic Specifications
Supply Voltage:
13 – 36 Vdc (13V @ 20mA)
Repeatability:
.005% of full scale or
.010”, whichever is greater
Non-Linearity:
.01% of full scale or .030”,
whichever is greater
Sensor Accuracy:
.01% of full scale or .020”,
whichever is greater
Damping:
1 to 25 seconds
Operating Temp:
-50 to 85 C
(-58 to 185 F)
Material:
5/8” 316ss standard, optional:
Hastalloy, Monel, or Kynar sleeved
Operating Temperature:
-50 to 149 C
(-58 to 300 F)
Maximum Pressure:
2000psig @ 300F
Range:
12 in. to 30 ft.