background image

© Baader Planetarium GmbH | 2020

9

If your telescope is equipped with a 2" eyepiece clamp, you can use the binoviewer 

with an optional 2" nosepiece 

# 2408150

. You can attach it either directly to the 

binoviewer with the TQC QuickChanger, or to an optional T-2 star diagonal. 

How to find the perfect Glasspath Corrector

For telescopes with an f-ratio of about f/7 or faster, you need a Glasspath Corrector 
(GC) to correct the colour aberrations introduced by the prisms at such fast tel-
escopes. It also moves the focal point outwards, which is necessary to reach focus at 
all at some telescopes. Besides three GCs especially for the astro T-2 system, there 
are also two special 2" GCs, one for Newtonians and one for lens telescopes and 
Schmidt-Cassegrains. You can find more about choosing the best GC in the adden-
dum, starting at page 20.

How to find the perfect Eyepieces

The MaxBright

®

 II Binoviewer features an optical window 

with a clear aperture of 26 mm, so you can use (almost) 
all standard 1¼" eyepieces.

The maximum outside body diameter of eyepieces 

that can be used with the binoviewer is about 58 mm. 
If the binoviewer is used with eyepiece having a larger 
diameter, for example the Pentax XW, you may have 
problems reaching the correct separation between the 
two eyepieces if the interpupillary distance between your 
eyes is less than 60 mm.

For observing the planets with high resolution, we 

recommend our Classic Ortho or even Carl-Zeiss-Abbe 
eyepieces. For general observations, we recommend the 
Hyperion 68° and the Morpheus 76° wideangle eyepiec-

es. These provide large eye 
relief and are very comfortable to use. 

It is extremely important to choose pairs of identical eye-

pieces made by the same manufacturer in the same period 
of time. It is quite common to find significant differences 
(optically and mechanically) in eyepieces of the same 
brand and type built at different periods of time. If you do 
not use identical eyepieces, you may experience problems 
merging the two images, because the brain can't handle 
these different images.

Largest Field of View

Usually, eyepieces with a focal length of 32 mm provide 
the largest possible field of view; eyepieces with longer 
focal length can give you "only" a brighter image because 
of their lower magnification. The reason for this is that the 

nosepiece (with the field stop inside of it) physically limits 

The Eudiascopic 35mm-eyepieces 
show a very large field of view, in spite 
of having only a 1¼" nosepiece.

Two 36 mm Hyperion

®

 Aspheric at 

the MaxBright

®

 II Binoviewer

Содержание 2456460

Страница 1: ...e you with a lifetime of amazing views To ensure optimal performance please read this instruction manual before using your binoviewer BAADER PLANETARIUM ZurSternwarte4 D 82291Mammendorf Tel 49 0 8145...

Страница 2: ...Diagonal 12 Option 2 Assembly with a 1 or 2 Nosepiece without Star Diagonal 13 Assembly with Zeiss Microbayonet 14 Option 1 Assembly with a T 2 Star Diagonal 14 Option 2 Assembly without Star Diagona...

Страница 3: ...remove colour aberration which will occur because of the long light path through the glass prisms in the binoviewer if it is used with fast telescopes with focal ratios between f 4 and f 7 because of...

Страница 4: ...ble T 2 Coupling Nut pre mounted 3 Zeiss microbayonet dovetail ring 4 Spanner tool to fix T 2 adapter or Zeiss Microbayonet to the bino viewer 5 ABS hard top case with compartment for a T 2 star diago...

Страница 5: ...20 mm 2456316 2456316Z 1 7x ca 35 mm 2456317 2 6x ca 65 mm 2456300 1 7x ca 80 mm 2 Glasspath Corrector for Newton to attach to the Zeiss microbayonet 2456305 1 8x ca 80 mm 2 Glasspath Corrector for R...

Страница 6: ...diagonal 36 mm Zeiss Prism 38 5 mm wit BBHS coating 2456130 T 2 90 Baader Astro Amici Prism with 48 mm BBHS coating for upright images 2456103 Baader T 2 BBHS star diagonal mirror 43 mm 2458055 FlipM...

Страница 7: ...m diagonal with 2 ClickLock clamp 2456117 Part Number Name Optical Length 2956100 Baader 2 ClickLock Mirror Diagonal 71 5 mm 2456115 Baader 2 BBHS Mirror Diagonal 71 5 mm 2456117 Baader 2 BBHS Prism D...

Страница 8: ...bodies small locking screws and a generally lightweight construction are inadequate to safely hold heavy accessories like a binoviewer Unfortunately it s quite common to hear about heavy and expensive...

Страница 9: ...iameter for example the Pentax XW you may have problems reaching the correct separation between the two eyepieces if the interpupillary distance between your eyes is less than 60 mm For observing the...

Страница 10: ...Universal Zoom Mark IV eyepieces are made so that they provide the best sharpness and the largest field of view at the highest magnification Simple zoom eyepieces are designed the other way round Tha...

Страница 11: ...an object close the right eye and look into the left eyepiece Using the telescope s focus mechanism adjust until the image is sharp 3 Close the left eye and with the right eye look into the right eye...

Страница 12: ...you simply screw one of the GCs 2456314 2456316 or 2456317 into the star diagonal without the centering plastic ring which is included with the glasspath corrector Our star diagonals provide a matchi...

Страница 13: ...with the glass path corrector to the binoviewer Rotate the counter nut until the nosepiece holds tight 4 Now put the binoviewer into the focuser of your telescope and secure it 5 Remove the dust cover...

Страница 14: ...o 1 25x and 1 7x glasspath correctors are moun ted into the dovetail at the binoviewer The 2 6x glasspath corrector is inserted into the T 2 star diagonals as shown here 2 6x GC 1 25x 1 7x GC Remove t...

Страница 15: ...r with several telescopes The two glasspath correctors with factor 1 25x and 1 7x can be screwed into the ring dovetail as described for option 1 Then you can use the TQC quickchanger 2456313A to conn...

Страница 16: ...he TQC QuickChanger and insert the eyepieces PLEASE NOTE This GC is inserted deeply into the telescope therefore it can only be used with Schmidt Cassegrains with a sufficiently large baffle or at tel...

Страница 17: ...to permit safe high resolution observation and imaging of the solar photosphere As the Herschel Solar Prism does not have T 2 threads on the top a T 2 2 adapter ring 1508035 is required Inserting the...

Страница 18: ...crewed directly into the binoviewer without the black plastic ring The 2 6 glasspath corrector must be put into the SC T 2 adapter 1508035 together with the black spacer ring It is locked in place by...

Страница 19: ...2 very compact and protected from accidental removal To do so you have to remove the T 2 counter nut or the Zeiss microbayonet The shortest possible adaptation can be achieved with the prism diagonal...

Страница 20: ...the focal point well past the focuser surface a larger secondary mirror would be required or at least moving the primary mirror up the tube which of course creates its own issues too This increases th...

Страница 21: ...lengths are approximate values allow for some variation e g for diopter adjustment Some telescopes don t have enough back focus for any of our glasspath correctors Try to avoid 2 star diagonals becau...

Страница 22: ...selecting the matching Glasspath Correctors you need to measure the back fo cus of your telescope first as described in the previous chapter Table 1 on the previ ous page then tells you which compensa...

Страница 23: ...lly the glass surfaces of your binoview er will not require anything more than a burst of clean air from a blower bulb in order to remove dust Avoid touching the optical window lens or the prisms insi...

Страница 24: ...5 www baader planetarium com kontakt baader planetarium de www celestron de G M B H 2020 Baader Planetarium All Rights reserved Products or instructions may change without notice or obligation Images...

Отзывы: