BA Pumps & Sprayers TSX400 Series Скачать руководство пользователя страница 13

0800 833 538 

www.bapumpsandsprayers.com

Oil Change:

Change oil after the first 500 hours as follows:

- Remove the tank plug and the drain plug
- Rotate the shaft to remove excess oil
- Wash inside the parts with Diesel oil

- Refill pump with oil through the glass and rotate the shaft to distribute oil and fill to the

 

   proper level

- Start pump and let run for a few minutes at zero to facilitate the correct lubrication of

 

   inside parts

USE ONLY “SAE 30” OIL

For all pumps without the drain plug normally oil is changed whenever the wear parts (like 
diaphragms, o-rings, valves assembly) are changed. Always perform this routine 

 

maintenance on the pump at the end of the season. Drain the oil from the pump by  
removing the pump heads one by one and the relevant piston sleeves.

Instructions for the correct use of the Pressure Regulation Valve:

1. Start the pump only when valve is in the “by-pass” position, let it run for at least two  
minutes and, in any case, until air has been vented from the hydraulic circuit.

2. Turn the valve lever clockwise to “Press” position, close the spray gun or spray boom, turn 
the adjustment knob clockwise up to  the working pressure selected, open the spray gun or 
spray boom and start spraying. 

Routine maintenance on the pump includes changing the diaphragms, oil, valves assembly, 
O-rings, all of which are normal wear parts.

BYPASS

PRESS

Содержание TSX400 Series

Страница 1: ......

Страница 2: ...ay tanks or other equipment must be filled only to a level where the gross weight is within the load limit of the UTV or another vehicle Never exceed the load limit capacity of the UTV or another vehi...

Страница 3: ...oint the spray gun at a human s body as high pressure spray may cause serious bodily harm After completing spraying task in the field turn the pump off at the switch and discharge the residual pressur...

Страница 4: ...t not attempt to correct or remedy such defect either by modification of adjustment or alteration to any part or parts of the machine This Warranty will stop by right if the product is used in a manne...

Страница 5: ...Pumps Sprayers does not pay for cleaning the sprayer parts accessories or work area before or after the warranty repair Clean up time is affected primarily by the application or conditions in which th...

Страница 6: ...ing but may be used in conjunctions with a boom for boom spraying Please read the safety instructions before installing or operating your sprayer Specifications Model Tank Length Width Height Dry Weig...

Страница 7: ...ction to 12 volt DC supply 12 Volt Model Only The sprayer requires a 12 volt DC power source A 2 metre loom is provided to allow the sprayer to be connected to the 12 volt DC battery The red wire is p...

Страница 8: ...onda Engine Pressure Adjustment Gauge MAX 215 PSI Spare tap for Boom or XP Kit Engine Oil Dip Stick Hose Reel Lock Pump Oil Level Oil shouldnot exceed max line PumpSightGlass Oilshouldnot beseeninsigh...

Страница 9: ...Adjustment Gauge MAX 580 PSI Engine Oil Dip Stick Hose Reel Lock PumpSightGlass Check oil level on pumpwhen running Oil shouldnot exceed max line Drain Tap Pump Suction Spare tap for Boom or XP Kit Ho...

Страница 10: ...around and underneath the engine for signs of oil or gasoline leaks 2 Remove any excessive dirt or debris especially around the muffler and recoil starter 3 Look for signs of damage 4 Check that all s...

Страница 11: ...gine switch to the ON position 5 Operate the starter Recoil starter by pulling the starter grip lightly until you feel resistance then pull briskly Return the starter grip gently DO NOT allow the star...

Страница 12: ...this can result in some leakages or diaphragm failures 2 Be sure that the inlet and discharge hoses are not crimped and the strainer is clean In any case be sure connections are tight to prevent any...

Страница 13: ...y are changed Always perform this routine maintenance on the pump at the end of the season Drain the oil from the pump by removing the pump heads one by one and the relevant piston sleeves Instruction...

Страница 14: ...cking air or air hasn t been evacuated completely Valves blocked Check pressure in pulsatio damper The liquid flow is irregular The air in the pulsation damper is incorrectly set Top up with oil to co...

Страница 15: ...Pumps Sprayers will not accept any liability for loss or damage consequential or otherwise arising directly or indirectly from the use of this equipment Chemical Advice BA Pumps Sprayers or their agen...

Страница 16: ...h chemical container label conditions and nozzle type With nozzles that reduce spray drift to a minimum With booms as close to the ground as practicable With less than a 5km wind Using the correct per...

Страница 17: ...0800 833 538 www bapumpsandsprayers com TSX400 PARTS LIST...

Страница 18: ...0800 833 538 www bapumpsandsprayers com TSX400 PARTS EXPLODED...

Отзывы: