Transmitting leading zeroes
10.5 Transmitting leading zeroes
A Customer may wish to have the data transmitted with leading zeros and not spaces.
The print format sequence would look like this …
[ = t501
indicates the start of an optional parameter
90 = Z
for leading zero parameters
49 = 1
for use leading zeros
] = t502
indicates the end of the optional parameter
For more examples of editing formats consult
Print tokens, parameters and default
.
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
The above token and function will output the text “Gross”
The above token and function will output the Gross weight value.
GROSS
lb
Characters 5 to 8 will add the leading zeros to the weight transmitted using an optional
parameter. You may need to refer to
for more detail on
necessary character values.