BTEK T403S Indicator User Instructions
13
3.1 General weighing application
3.1.3 Net weighing
Net weighing is available via three types of tare entry.
Pushbutton tare
When enabled press
TARE
to tare the weight on the scale.
Entered tare
When enabled key in a tare weight and press
TARE
to set.
Preset tare
When enabled press
TARE
to recall a preset tare numbered 1-10.
There is an auto tare clear feature. If this is enabled, after a weighment, when the
weight falls into the gross zero band, tare is cleared to zero.
The three types of tare are explained below.
Using Pushbutton Tare
To perform a net weighment using pushbutton tare, power up the unit and follow these
steps:
1.
With no weight on the scale, if the display does not read
0
press
ZERO
…
0
is displayed and the
center-of-zero
annunciator lights.
2.
Place item to be tared on the scale …
Weight is displayed.
3.
Press
TARE
…
0
is displayed and the
NET
annunciator lights.
4.
Place material to be weighed into or on the tared item on the scale …
Net weight of material is displayed.
5.
Repeatedly press
SELECT
to view the gross, tare, and net values.
6.
If repeated weighments use the same tared item, you do not need to establish
a new tare value as described in step
and
.
Pushbutton and Entered Tares can be enabled simultaneously. If Preset Tare is
enabled, Pushbutton and Entered Tares are automatically disabled.
Definition: Gross zero band - this is a configured value that defines a window around
gross zero. This is used in several ways in different applications.
If gross weight is not at 0, press the
ZERO
key; then press the
TARE
key to clear the
tare value.
Содержание T403S
Страница 1: ...T403S Indicator User Instructions AWT35 501633 Issue AA ...
Страница 2: ...BTEK_T403S_u_en_501633 book 2016 B TEK All rights reserved ...
Страница 72: ...72 BTEK T403S Indicator User Instructions Supervisor menu ...
Страница 73: ......
Страница 74: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...