Page 8
6.2.
Exhaust Ducting Painty-02/04
The exhaust air hose must be integrated in the exhaust system at the installation site and must be
routed outdoors properly into the so-called "free air space". Place the exhaust air hose vertically, a
minimum of one metre for optimal function of the exhaust system and stretch the hose as far as pos-
sible in order to avoid a reduced cross-section. In this way optimal exhaust suction will be achieved.
Ensure that fumes are not directed into areas where people are likely to be. The exhaust air has to be
led away safely. That means according to ATEX and especially not into flues serving furnaces or fire-
places and not into the exhaust ducts of spraying and drying cabinets. In case the exhaust system con-
ditions at the installation site require a longer exhaust air hose or the instructions in how to route the
exhaust air system cannot be complied with, please contact an ATEX-ventilation system specialist to
ensure safe operation.
It’s recommended not to connect the
product directly to a rigid pipe. Use at least 30-40 cm of the
flexible B-TEC exhaust hose to ensure that the product can be relocated or repaired conveniently if
necessary.
Diameter of exhaust hose: Ø125 mm
The exhaust air flow rate can be adjusted at the flow adjuster as needed depending on the length
of the duct.
Caution! Only use original B-TEC exhaust air
hoses! Risk of fire! Do not use plastic hoses!
Figure 1 - Painty-02
–
Extraction for diameter 125mm
Figure 2 - Painty-04
–
Extraction for diameter 125mm