background image

EPL-100BT-12V-G2

3.90V ± 0.03V

5s Auto Release

Disconnect Load

Protection to 65°C ± 5°C

Release at 50°C ± 5°C

Release at 55°C ± 5°C

Release at 45°C ± 5°C

Auto release after 5s

Length 318mm

Length 318mm

Length 505mm

Width 165mm

Width 165mm

Width 172.5mm

Height 215mm

Height 215mm

Height 265mm

Approx 12.6 kg

Approx 15.0 kg

Approx 25.0 kg

≤30 days -20°C to 35°C, 

45 to 75% RH

≤ 30 days -20°C to 35°C,

45 to 75% RH

≤ 30 days -20°C to 35°C,

45 to 75% RH

≥ 30 days -10°C to 30°C,

45 to 75% RH

≥ 30 days -10°C to 30°C,

45 to 75% RH

≤30 days -20°C to 35°C,

45 to 75% RH

≤3% Per Month

≤3% Per Month

≤3% Per Month

Battery Discharge Over Temperature

Battery Charge Over Temperature

Short Circuit Protection

Mechanical Characteristics

Dimensions

Weight

Storage Information

Temperature & Humidity Range

Self-Discharge Rate

Over Temperature Protection

12.8V

≤11.20V

≤11.20V

≤11.20V

≤60A

100Ah

11.20 - 14.60V

Discharge below release voltage

Over-Charge Release Per Cell
Over-Charge Release Method

Circuit Protection

Section 9 - Battery Specifications

www.enerdrive.com.au

Page 13

Enerdrive B-TEC Lithium Battery Technical Data

Normal Specification

EPL-100BT-12V-G2

EPL-125BT-12V-G2

EPL-200BT-12V-G2

Standard Charge Specification (Lithium profile charger required)

Standard Discharge Specification

Nominal Voltage

12.8V

12.8V

≤2000 Cycles

≤33A

≤40A

0 - 45°C

60A @ 25°C for 30 mins

-20 - 60°C

11.20 - 14.60V

11.20 - 14.60V

450A for 1.0s

100A @ 25°C ± 5°C for 30 mins 100A @ 25°C ± 5°C for 30 mins 200A @ 25°C ± 5°C for 30 mins

3.60V ± 0.05V

80A @ 25°C for 30 mins

150A @ 25°C for 30 mins

14.20 - 14.60V

14.20 - 14.60V

14.20 - 14.60V
13.50 - 13.80V

13.50 - 13.80V

13.50 - 13.80V

125Ah

200Ah

Nominal Capacity

Battery Charge Temperature
Normal Charge Voltage CV/CC*
Standby (Float) Voltage
Maximum Charge Current

Battery Discharge Temperature
Battery Output Voltage Range
Maximum Discharge Current
Pulse Discharge Current

Discharge Cut-off Voltage

Over-Charge Protection

Over-Charge Protection Per Cell

2.80V ± 0.05V

Yes

Yes

Yes

3.20V ± 0.05V

110A for 30s - 450A for 1s

110A for 30s - 450A for 1s

220A for 30s – 450A for 1s

Apply Charge/Voltage ≥12.8V  Apply Charge/Voltage ≥12.8V  Apply Charge/Voltage ≥12.8V

Over-Discharge Protection Per Cell
Over-Discharge Release Per Cell
Over-Discharge Release Method

Battery Manual Reset Button

Discharge Over Current

Protection Reset Time

Over Current Release Method

Over Current Protection

Over-Discharge Protection

The battery is supplied with a LiFeP04 Battery Management System (BMS) that can monitor and optimise each single prismatic cell during charge and discharge, to 
protect the battery pack from overcharge, over discharge and short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery.

Recommended Charge Current for Maximum Life

Cycle Life (DOD-80% under controlled conditions)

Содержание Lithium EPL-100BT-12V-G2

Страница 1: ...Enerdrive B TEC Lithium LiFePO4 Lithium Ion Phosphate Prismatic Cell Battery with Smart Phone Monitoring Enerdrive B TEC G2 Manual Rev 2 1 EPL 200BT 12V G2 EPL 100BT 12V G2 EPL 125BT 12V G2...

Страница 2: ...attention to the CAUTION and WARNING statements While every precaution has been taken to ensure the accuracy of the contents of this guide Enerdrive assumes no responsibility for errors or omissions N...

Страница 3: ...NG THE BATTERY SECTION 4 PROTECTING YOUR BATTERY SECTION 5 RESTARTING YOUR BATTERY SECTION 6 USING THE BLUETOOTH BATTERY MONITOR APP SECTION 7 WARNINGS SECTION 8 FAQ SECTION 9 BATTERY SPECIFICATIONS S...

Страница 4: ...ion There is no need to over tighten the bolts simply ensure there is no movement of the cables Make sure the main Battery Cable lug is mounted directly onto the Battery terminal with no washers betwe...

Страница 5: ...r currents but the recomended 60 Amps or less is recommended See Section 9 Battery Specifications Note You can charge a lithium battery with a non lithium charger but these chargers can deliver too mu...

Страница 6: ...you MUST USE cable of the correct guage These are recommended wire guages and approximate current specifications for cable lengths shorter than 1 2 meters Guage 2 35mm 100 Amps Guage 0 50mm 150 Amps...

Страница 7: ...ch uses a shunt to measure the current going into Charging and coming out of Discharging the battery Example 200 Amp Battery Fully Charged State of Charge 100 50 Amps used State of Charge 75 100 Amps...

Страница 8: ...Release and wait 7 seconds 5 Power should now be restored and charging will commence 6 When the SOC State of Charge is above 20 loads can be switched on if required By continuously tripping the low vo...

Страница 9: ...ndividual Cell Voltage Battery Voltage Battery Temperature Battery Current Amps Battery Cycles Battery State of Charge SOC Battery Alarms Battery State of Health SOH Battery Event Information Battery...

Страница 10: ...Enerdrive Pty Ltd is not responsible for any accidents cause by the usage without following our specification The battery has a low voltage disconnect incorporated for self protection If the battery...

Страница 11: ...ure they are fully charged separately then let sit for 30 minutes before connecting together When connecting in parallel take the positive from Battery 1 and the negative from Battery 2 to your system...

Страница 12: ...TEC battery A Of course We recommend an inverter size of 1000 watts maximum for the 100 125Ah batteries and 2000 watts maximum for the 200Ah battery Q Can I install the B TEC battery in a wet area A I...

Страница 13: ...00 Cycles 33A 40A 0 45 C 60A 25 C for 30 mins 20 60 C 11 20 14 60V 11 20 14 60V 450A for 1 0s 100A 25 C 5 C for 30 mins 100A 25 C 5 C for 30 mins 200A 25 C 5 C for 30 mins 3 60V 0 05V 80A 25 C for 30...

Страница 14: ...ds come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseea...

Страница 15: ...to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and mainte...

Страница 16: ...Page 14 Enerdrive B TEC G2 Manual Rev 2 1...

Страница 17: ...enerdrive com au Page 15 110 00 41 00 41 00 131 00 131 00 131 00 30 00 170 00 475 00 30 00 4mm 4mm Fastening Holes fasteners not included fasteners not included Fastening Holes Flat Battery Reset But...

Страница 18: ...ENERDRIVE PTY LTD P O Box 9159 Wynnum Plaza Queensland Australia 4178 Ph 1300 851 535 Fax 07 3390 6911 Email support enerdrive com au Web www enerdrive com au...

Отзывы: