8
Yearly Checks & Service
The appliance should be inspected and adjusted periodically by a qualified service person as
part of any kitchen maintenance program.
B&S recommends that this appliance is inspected at least annually by a authorised service
technician as follows:
o
Inspect the table inside-out for excessive build-up of any fats, oils and foodstuffs.
o
Inspect that the burners and other components (i.e. pilots, thermocouples, etc.) are in good
condition and functioning properly.
o
Inspect all gas connections for leaks and ensure all connections are tightened properly.
o
Ensure burner manifold pressure is in accordance with that specified on the data plate of the
appliance.
o
Inspect all gas connections for leaks and ensure all connections are tightened properly.
In case of difficulties, contact B&S Commecial Kitchens Pty Ltd or their authorised service agent.
Servicing Instructions
WARNING!
Servicing shall be carried out by autorised personnel
only
. Failure to do so will void
the B&S warranty and may result in damage to equipment or injury to personnel.
Before commencing any disassembly/ assembly of gas controls, please ensure the
gas supply is turned off (isolated).
FAILURE TO DO SO WILL VOID B&S WARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT
OR INJURY TO PERSONNEL.
Gaining Access to Gas and/or Water System
To gain access to gas system/components;
1.
Gently remove pilot control knob by pulling backwards.
2.
Undo screw located at the centre of the main gas handle, and gently remove handle.
3.
Undo front panel screws located on the bottom left and right hand corners of the front panel.
4.
Grip front panel from the bottom and gently pull forward and downwards.
5.
REASSEMBLE IN REVERSE ORDER.
Pilot and Flame Safeguard
1.
Access to pilot assembly is gained by removing the wing-nut located to the right of the pilot assembly
which secures it to the lug located on the burner.
2.
Gently pull upwards to gain greater access.
3.
To service/remove the thermocouple;
a. Undo the nut located underneath and above the thermocouple at the pilot assembly and
gently pull thermocouple downwards.
b. Remove thermocouple from flame failure valve by unscrewing.
c. Reassemble in reverse order.
4.
To service/remove pilot burner;
a. Remove thermocouple as prescribed in 3.
b. Undo nut securing gas inlet to pilot assembly.
c. Gently pull down pilot flexible gas tube.
d. Remove injector from pilot and clean (if required).
e. Reassemble in reverse order.
5.
REASSEMBLE IN REVERSE ORDER.