4/17
1, Dome setting Instruction
The switch setting SW1
ON=1 OFF=0
Protocol setting
Baud rate setting Alarm
Alarm mode
DIP Switch
1
2
3
4
5
6
7
8
SW1234=
0000=PELCO-D/PELCO-P Auto
identify
SW5,6=
00=2400
01=4800
10=9600
1=Alarm
enable
0=Alarm
disable
1=Always short
circuit.(Alarm
while open)
0=Always
open
circuit.(Alarm
while short)
Note
:
PELCOD PELCOP could be identifying automatically. On and Off is the corresponding
switch positions.
SW2 switch: address switch table.
CAM
ID
1 2 3 4 5 6 7 8
1 OFF OFF OFF OFF OFF OFF OFF OFF
2 ON OFF OFF OFF OFF OFF OFF OFF
3 OFF ON OFF OFF OFF OFF OFF OFF
4 ON ON OFF OFF OFF OFF OFF OFF
5 OFF OFF ON OFF OFF OFF OFF OFF
6 ON OFF ON OFF OFF OFF OFF OFF
7 OFF ON ON OFF OFF OFF OFF OFF
8 ON ON ON OFF OFF OFF OFF OFF
9 OFF OFF OFF ON OFF OFF OFF OFF
10 ON OFF OFF ON OFF OFF OFF OFF
11 OFF ON OFF ON OFF OFF OFF OFF
12 ON ON OFF ON OFF OFF OFF OFF
13 OFF OFF ON ON OFF OFF OFF OFF
14 ON OFF ON ON OFF OFF OFF OFF
15 OFF ON ON ON OFF OFF OFF OFF
16 ON ON ON ON OFF OFF OFF OFF