means resetting is complete. 

4) The reset feature works only when the device has been included into a Z-Wave network.

 

 

 
 
 
NOTE 

Use this procedure only in the event that the network primary controller is 
missing or otherwise inoperable. 

 

 

 
 

.FCC NOTICE 

This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the  following  two 
conditions: 
 (1) This device may not cause harmful interference, and 
(2)  This  device  must  accept  any  interference  received,  including  interference  that  may  cause 
undesired operation.  

 

Содержание B1MS02-ZW-AU

Страница 1: ...an be included and operated in any Z Wave network with other Z Wave certified devices The features list 1 Z Wave Plus certified for wide compatibility 500 serials product 2 Supports security 0 and sec...

Страница 2: ...2MHz US 921 42MHz ANZ Range More than 100m outdoors About 30m indoors Dimensions 50mm Working current About 50mA Standby current About 55uA Recommended installation height 2m 4m INSTALLATION 1 Turn th...

Страница 3: ...r triple click the Z button quickly the LED indicator should blink fast 5 Wait for the adding process to end 6 Successful adding will be confirmed by the Z Wave controller s message NOTE If you want y...

Страница 4: ...Button turn off when Z Button is released Press and hold for more than 3 seconds 1 Led blink fast then turn off B One Motion Sensor is in the Z Wave network Trigger Description Short press one time w...

Страница 5: ...RITY V1 COMMAND_CLASS_SECURITY_2 V1 COMMAND_CLASS_TRANSPORT_SERVICE V2 COMMAND_CLASS_SUPERVISION V1 COMMAND_CLASS_FIRMWARE_UPDATE_MD V3 COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 security COMMAND_CLASS_ZWA...

Страница 6: ...is triggered 1 3Notification command parameters parameters Value Supported Notification Type Home Security 07 Supported Event Motion Detection Unknown Location 08 Tampering Product covering removed 03...

Страница 7: ...n Sensor can reverse its value of BASIC SET when motion is triggered 0 Send BASIC SET VALUE 255 to nodes associated with group 2 when motion alarm is triggered Send BASIC SET VALUE 0 to nodes associat...

Страница 8: ...s detection area such as trees blowing in the wind cars passing by windmills False motion alarms may be caused by moving masses of air and heat as well If the device keeps on reporting false alarms de...

Страница 9: ...ent that the network primary controller is missing or otherwise inoperable FCC NOTICE This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This dev...