40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
PROJECT:
TYPE:
4. Mount faceplate using two (2) #10-24 hex
screw. Tighten to compress gasket. Do not
over tighten.
3. To aim adjustable bracket -loosen the two (2)
phillip screws attaching the adjustable bracket
to the faceplate. Aim to desired position.
Tighten two (2) phillip screws to lock in place
when desired angle is set.
Phase 2 - Finish Installation of Fixture with Remote Transformer
LINE
12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
1. Remove #10-24 Stainless Steel Phillips screws
from mounted back box. Install universal
mounting ring (supplied with faceplate) using
#10-24 screws onto back box. Align faceplate
mounting holes to final mounting position.
See wiring diagram.
2. Make two connections from remote 12V
transformer to LED source leads (18 gauge
wire) using proper wire connectors (By
Others).
Phase 1 - Rough In
Installation of Back box
1. Install Conduit (by others) to be used with
this product.
2. Install junction box so that front face is flush
with finished wall or ceiling.
3. Connect box to conduit and pull wires for
connections (See Wiring diagram).
Additional Info
• Please follow National and Local electrical codes for your area.
• 4” round cast box is provided with Five (5) 1/2” threaded hubs
for conduit entry (4 on sides and one on back of box).
• Suitable for through wire.
• Suitable for installation into combustible materials.
• Rated for 90° C.
Please refer to the low voltage design guide at www.bklighting.com/
lvguide before installation for proper wire selection.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
3167387
ETL LISTED
CONFORMS TO ANSI/UL STANDARD 1838,
CERTIFIED TO CSA STD C22.2 NO.250.7
CSA STD C22.2 TIL B-58A
SS /SSL™/VS™/VSL™
Round Back Box Installation Instructions
PRELIMINARY
12-12-11
REFERENCE
NUMBER
INS000938
TECHNOLOGY
with