B-K LIGHTING

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

Remote Transformer

5.  Make watertight connections from remote 

transformer to fixture source  leads using 

waterproof wire connectors (By Others).  

See 

wiring diagram.

4.  Pull low voltage wire or pull branch circuit 

wires necessary for installation (By Others) 

through anchor base. 

 

Anchor base can accommodate up to two (2) 

1/2” conduits. 

7.   Place fixture on anchor base and tighten four 

(4) #10-32 stainless steel button head cap 

screws using a  1/8” Allen wrench.

120V

12V

Fixture

COM

Remote

Transformer

COM

120V

12V

Fixture

COM

GROUND

Integral 

Transformer

COM

GROUND 

Integral Transformer

6. 

 

Use waterproof wire connectors 

 

(By Others) to make watertight connections 

from transformer primary leads to branch circuit 

wires. Connect incoming ground to ground wire 

provided in fixture body. 

See wiring diagram.

WIRING DIAGRAM

3.

50

1.

50

1.  Determine suitable anchors (By Others) to 

attach anchor base to architectural surface. 

2.  Place provided template in final mounting 

position according to designed lighting plan. 

3.  Drill holes into surface for maximum 7/16” 

fasteners (By Others) on locations illustrated 

on template. Base mounting hole locations is 

1-1/2” on center by 3-1/2” on center apart.

PROJECT:

TYPE:

(33mm)

1 5/16"

(76mm)

3"

Specify
Length

 BS-LED

   S000891

1 3/8"

(35mm)

(4) 3/8" Dia.  (10mm)

Bolt Holes

Slip Anchor

(38mm)

2" Dia.  (51mm)

O.C.

Slip Conduit Hole

1 1/2"

3 1/2" O.C.

(89mm)

68° Angle = A

90° Angle = B

5"

(127mm)

PS™ / BS™/ PSL™ / BSL™

 Installation Instructions

REFERENCE

 

NUMBER

INS000733

TECHNOLOGY

with

TECHNOLOGY

Anchor Base Installation

TRANSFORMER HOUSING MUST BE INSTALLED ABOVE GRADE. 

TRANSFORMER HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY

& Low Voltage

120V

12V

Fixture

COM

Remote

Transformer

COM

120V

12V

Fixture

COM

GROUND

Integral 

Transformer

COM

GROUND 

WIRING DIAGRAM

8.  Use 1/8” Allen wrench to loosen #10-24 stainless 

faceplate screws to remove faceplate. for access 

to source.