1. Remove faceplate from collar using two (2) #8-32
flat head screws (included) with a 9/64” allen
wrench.
Fixture Relamping
2. Remove fixture from collar.
3. Loosen two (2) #8-32 screw with a 5/64” allen
wrench to remove faceplate.
4. Space three fingers evenly around the optic and
gently rock optic to remove.
6. Disengage LED board and driver assembly.
Replace with new board and driver assembly.
7. Reverse install LED board and driver by carefully
engaging quick disconnects and inserting into
fixture body. Secure LED board in place with
stainless steel screws. Snap optics in place.
8. With flat head screw driver rotate dial to desired
lumen output. Replace fixture in mounting collar.
5. Use a 5/64” allen wrench to remove two (2) #2-56
socket head cap screws on LED board, grasp
LED board and gently pull up to expose quick
disconnect.
9. Mount faceplate to collar using two (2) #8-32 flat
head screws (included) with a 9/64” allen wrench.
Do not overtighten.
RELEASE DATE
12/15/2021
REFERENCE NUMBER
INS-2317-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
B-K LIGHTING
ARTISTAR UPLIGHT
Flush Mount
Standard Installation