B-I INDUSTRIAL CO., LTD.
SMOKE DENSITY INDICATOR
DELAY : 15 SECONDS, Set by 0~60 sec. range and 5sec.
(after detection of smoke, Delay when Ararm, High & High High signal output)
FILTER : 1, Select proper value among 0~9.(Sensitivity of smoke sensor)
ZERO : Setting is configured when delivered but reconfiguration is recommended after
installation.
SPAN : 100% SPAN, Setting is configured when delivered but reconfiguration is
recommended after installation.
4-20mA : Signal output to ECR. (It is not necessary to reconfigure after installation)
2-1-4 Setting
If you press
for 5 seconds, Setup Menu is displayed. By means of button, you can
move to another menu. The sequence of Setup menu display is as follows:
You can start to set up, if you press button
BI-SM2004.doc