Ambient Light Level Adjustment
Control Panel Cover
LED Indicator
OFF VAC VAC
TIME
TEST
5
20
30
Min
Min
Min
RANGE
3
2
Mounting Yoke
Fresnel Lens
OFF VAC VAC
4
1
Neutral
White
Hot
Black
Ground
Green
Load
Red
Load
- 01-
-03-
-02-
DESCRIPTION
P
art Number: 97334
Voltage .................................................................... 120/277VAC, 60Hz
Incandescent .........................................................................… 800W
Motor .............................................................................................1/4HP
Time Delay.....................................................................15Sec to 30Mins
SPECIFICATIONS
WAVE-PIR-120/277
VACANCY
SENSOR
SWITCH
INSTALLATION
Turn off the circuit breaker before installation.
WARNING:
Do not exceed electrical ratings.
Line(Hot), Red lead to Load wire, Green lead to Ground.
2. Gently position wires in wall box, attach sensor switch to the box.
3. Mount device “TOP”up.
4. Restore power at circuit breaker or fuse, wait
6. Locate the adjustment knobs on the control panel to perform test and
ADJUSTMENT
INSTALLATION INSTRUCTIONS
Light Level...................................................................... 30 Lux--Daylight
Indoor use only.
Wiring Diagram:
Figure 2
VAC
Mode
OFF
VAC
Description
Position
Left
Center
Right
Vacancy Mode: Manual On only,
automatic Off after set time delay.
React to the push-button
Manually toggles
Manually toggles
1. Connect lead wires as WIRING DIAGRAM (see Figure 2): Black lead to
Coverage Area
Band switch prescription.
5. Remove the small cover plate. (illustrated as Figure 3. )
7. Replace the small cover plate after testing and adjustment.
8. Attach the wallplate.
Figure 3
On / Off the load.
On / Off the load.
adjustment.(illustrated as Figure 3. )
Default position: 15 Seconds (Test mode)
Adjustable: from 15 Seconds to 30 Minutes (clockwise)
Default position: Center at 65%
Adjustable: 30% (Position 1) to 100% (Position 4)
Note: Turn toward right for greater room space.
Turn toward left to avoid false alert in smaller room and near
the door way or heat source.
Time Delay knob
Sensor Sensitivity Range Knob
three
minutes.
Fluorescent/Ballast
/LED
.............. 800VA@120VAC /1600VA@277VAC
Ground wire is required.
Manually toggles
On / Off the load.
Operation Temperature....................................................... 32°F--131°F
The coverage range of the sensor switch is specified and illustrated
the light to turn off eventhough someone is still in the detection area.
in Figure 1. Large objects and some transparent barriers like glass
windows will obstruct the sensors' view and prevent detection, causing
Best: 320 sq.ft.
Figure 1
Regular: 800 sq.ft.
Maximum: 1200 sq.ft.
40'
Top View
20'
10'
20'
10'
20'
5'
4'
Circuit is permanently opened
(switched off)
After Initial Run (3 minutes), set the Band Switch to VAC, press and
hold the Manual ON/OFF Button for 6 seconds until the Load turns on,
release the button within the next 4 seconds, the Load will turn off and
stay off or a maximum 10 seconds. The Load will turn on again (2
seconds) and then Off. It confirms that the present light level becomes
(Push-button)
The passive infrared sensors work by detecting the difference between
heat emitted from the human body in motion and the background space.
If no motion is detected after the set time delay, the load turned off
automatically. The sensor switch has one relay ( equal to single pole
switch), also includes Ambient Light Level Sensor.
Figure 4
10 Min
Vacancy Mode: Manual On only,
automatic Off after set time delay.