background image

2

1:4
 

1.

 

0.5

 

0.25

Futura Book 24Pt

1

LUXOMAT

®

 

RC-plus next

1:4
 

1.

 

0.5

 

0.25

Futura Book 24Pt

1:4 
 

1.

 

0.5

 

0.25

Futur

a Bo

ok 24Pt

1:4

 

1.

 

0.5

 

0.25

Futur

a B

o

ok 24P

t

1

2

3

1

3

2

4

TEST

16

12

8

4

15s 30s

1

1,5 2 3 5 6 7 10

+

-

1

2

1:4
 

1.

 

0.5

 

0.25

Futura Book 24Pt

180°

10°

1

2

45°

1

2

max min

1

2

3

1:4 
 

1.

 

0.5

 

0.25

Futur

a Bo

ok 24Pt

> 1m

4

1

2

2.5m

21m

8m

3m

1m

2.5m

21m

8m

1m

2.5m

21m

8m

1m

3m

21m

8m

1m

3m

21m

21m

21m

21m

8m

1m

3m

21m

8m

1m

3m

2.5m

21m

8m

3m

1m

2.5m

21m

8m

1m

2.5m

21m

8m

1m

3m

21m

8m

1m

3m

21m

21m

21m

21m

8m

1m

3m

21m

8m

1m

3m

2

3

1

2.5m

21m

8m

3m

1m

2.5m

21m

8m

1m

2.5m

21m

8m

1m

3m

21m

8m

1m

3m

21m

21m

21m

21m

8m

1m

3m

21m

8m

1m

3m

130°

230°

280°

1:4
 

1.

 

0.5

 

0.25

Futura Book 24Pt

4

11

10

7

8

9

5

3

2

1)  Push in cover-up clips on marked place 

(blind out distant range/close-up range/

both)

2)  Cover-up stickers

Operating and mounting instructions for motion detector LUXOMAT

®

 RC-plus next

1) 

Caution: have all work involving the 230 V 

mains supply carried out by a qualified 

electrician! Before starting disconnect the 

mains! Please be aware, that the LUXOMAT

®

 

RC-plus next is not suitable as an intrusion 

detector, since it is not equipped with a 

tamper contact.

2)  Socket base corner mounting

3)  In the case of mounting over the previous 

socket “RC-plus” use the extra cover that is 

provided.

1)  Wall mounting

2)  Ceiling mounting

3)  Outside corner mountable with plug-in 

socket (included with the RC-plus 

next

 280, 

see point 20)

1)  Connection cable from top down

2)  Connection cable from below

3)  Connection cable from behind

4)  Terminal markings 

(Wiring diagrams see point 17)

1)  Press here for separation of terminal case 

and plug-in socket 

2)  Mount the plug-in socket with two screws 

and the enclosed seal rings on a firm base 

(Pay attention to inserting of the connection 

cable, see point 4)

3)  Imprint the terminal case on plug-in socket. 

The terminal case on the plug-in socket is 

rotatable upto 10° for fine adjustment of the 

motion detector. 

Mechanical range adjustment

+

: e.g. 21m, 

: e.g. 5m (mounting height 2.50 m)

mounting height min. = 2.00 m

(RC-plus 

next

 130: 1 zone; RC-plus 

next

 230: 

2 zones; RC-plus 

next

 280: 3 zones, see point 8)

Follow-up time

Test operation, 15 sec. ... 16 min., Pulse operation

(Test operation: range testing, detector switches 

on/off the lighting at any recognized movement)

Lux value

Night operation...Dusk...Day operation

(Day operation: light sensor inactive, switching at 

any brightness value)

On delivery the potentiometers are adjusted in 

position “TEST” and “SUN” symbol (daytime 

operation). With this adjustments the following 

regular values are active:
Follow-up accommodation: 3 min.

Lux value: approx. 20 Lux

Reset:

 The adjusting into “Factory settings” from 

any other position causes a “Reset” of the device. 

That means all parameters are resetted into factory 

settings (fast LED-flashing).

LED Functional display

Display of movements and operating states

(Switchable with remote control 

LUXOMAT

®

 IR-RC, 

see point 11)

1)  If possible mount unit on a safe place  

(wall or ceiling mount). 

2)  Influence of weather reduces the lifetime of 

the unit. Please take care to mount correctly. 

3)  Minimum distance to switched lighting, 

frontally or laterally to device: 1m 

4)  Never mount the connected lights below the 

motion detector!

1) 

LUXOMAT

®

 IR-RC (accessory, see point 20)

2) 

LUXOMAT

®

 IR-RC-Mini (accessory, see 

point 20)

Caution:

 Settings with remote control subscribe 

the settings by courtesy of potentiometers (see 

point 5 ) (for description see point 12).

1)  Remove the coverring with slightly pressure

2)  Adjust Range, follow-up accommodation and Lux value with screwdriver

1)  Range walking across: approx. 21m

2)  Range walking towards: approx. 7 - 8 m

3)  Anti-creep: approx. 1 - 3 m

1)  Change range or sensitivity adjustments 

by swivelling of the sensor head vertically 

or horizontally (Sensor head horizontally = 

max. range)

2)  Fine adjustment of sensor axis

Mechanical range adjustment possible 

for every zone separately (see point 5)

Self test cycle

After mounting and connecting the 230 VAC supply 

voltage, the LED flashed for 1min. to show a self testing 

unit. Then the unit is ready for operation and the set-

tings can be made manually or with remote control 

(see point 11).

 6

 

&

 

“TEST”

TEST

16

12

8

4

15s 30s

1

1,5 2 3 5 6 7 10

3

GB

1. Mounting preparations

2. Mounting types

4. Inserting of the connection cable

3. Plug-in socket

5. Putting into operation / Settings

9. Exclude sources of interference

8.  Sensitivity adjustment (mounting height 2.50 m); 

mounting height min. = 2.00 m 

(Sensor head justified horizontally, see point 7)

7. Sensor head optics

6. Factory settings

10. Mounting place

11. Settings of remote control

3

2

1

10°

Отзывы: