3.Puttingintooperation/Settings
Factory settings
The PD4-M-GH is presetted with time setting 5 min. and twilight switch
1000 Lux.
Attention:
No settings on the unit are possible with potentiometers. Modifications are
only available by remote control IR-PD4-GH.
Installation and Operating Instruction for B.E.G. - Occupancy detectors PD4-M-GH-SM
2a.InstallationoftheLUXOMAT
®
PD4-M-GH-SM
Unlocking device
Lock device
4.Settingscarriedoutusingremotecontrol(optional)
Remote control LUXOMAT
®
IR-PD4-GH
1. Check Battery:
open battery compartment by pressing the plastic
springs together and removing the battery-holder.
Caution:
Settings with remote control supersede the settings
by courtesy of potentiometers.
1.Mountingpreparations
Work on the 230 V mains supply
may only be carried out by quali-
fied professionals or by instructed
persons under the direction and
supervision of qualified skilled
electrical personnel in accordance
with electrotechnical regulations.
Disconnect supply before installing!
When in Master/Slave mode of
operation, the Master-appliance
must always be installed at the
location where there is least
daylight.
Luminance set point
Sun button - preselected light
daylight operation
Automatic reading in the current light value
as new luminance set point
Individual light value 10 - 2000 Lux
Follow-up time (relay and Channel 1)
15 sec. upto 30 min.
Impulse function (relay and Channel 1)
1 sec. ON, 9 sec. OFF
Change between operation modes fully automatic/
semi automatic mode => (see page 2, point 6)
Semi automatic: green LED,
Fully automatic: red LED on for ca. 3 sec.
Determination of the switch on threshold
to attain a calculatory target value
Resetting when open
All values which have been programmed using the
remote control IR-PD4-GH are deleted, and those values
which have been set by potentiometer are activated.
Lock device
Test mode
Reset to deactivate
Resetting when closed
The lighting relay is switched off, i.e.
opened and the follow-up times reset.
Light on/off
The light will remain switched on/off for as long as move-
ments are detected in the areas of coverage. Once the last
movement has been detected, the light will remain on for
the duration of the follow-up time as per setting.
The appliance will then return independently to the mode
selected (Fully or Semi-automatic).
Option:
Wall bracket for remote control
IR-PD4-GH
The product enters an initial 60-second
self-test cycle, when the supply is first
connected. The occupancy detector is
ready for operation.
2c.Selftestcycle
IR-PD4-GH
IR-PD-Mini
B.E.G.
LUXOMAT
®
PD4-M-GH-SM
The detector must be installed on a solid and
level surface. The circular cover ring must be removed
prior to assembly. To do this, twist the lens (C) anti-
clockwise through approximately 5° and lift off.
Having connected up the wires in accordance with
regulations, secure the detector with 2 screws.
After installation replace the lens and lock (turn clock-
wise). Mains to be connected
.
ATTENTION:
Install the unit in such a manner that
both markings on the housing are positioned in the
longitudinal axis of the area to be monitored (e.g.
high-bay corridors)
5. PD4-M-GH-SM - Dimensions
with jumper
= switched live (L‘)
without jumper = potentialfree
2b.Rangeindependencefromthemountingheight
Mounting
height
Range (circular detection) T=17°C
walking across
2.00 m
r=7.50 m
Ø=15.00 m
2.50 m
r=9.00 m
Ø=18.00 m
3.00 m
r=11.00 m
Ø=22.00 m
3.50 m
r=13.00 m
Ø=26.00 m
4.00 m
r=15.00 m
Ø=30.00 m
4.50 m
r=17.00 m
Ø=34.00 m
5.00 m
r=18.50 m
Ø=37.00 m
6.00 m
r=18.50 m
Ø=37.00 m
7.00 m
r=18.50 m
Ø=37.00 m
8.00 m
r=22.00 m
Ø=44.00 m
9.00 m
r=22.00 m
Ø=44.00 m
10.00 m
r=22.00 m
Ø=44.00 m
r=radius / Ø=diameter
15
sec
30
min
+
HA
ON HA
OFF
close
open
B.E.G.(UK)Ltd.
The Lightbox
111, Power Road, Chiswick
W4 5PY
Tel:
0870.850 5412
Fax:
0870.850 5413
E-Mail: [email protected]
Internet: www.beg-luxomat.com
B.E.G.BrückElectronicGmbH
Schlosserstr. 30
51789 Lindlar
Tel:
02266.90 12 10
Fax:
02266.45 092
E-Mail:
Internet: www.beg-luxomat.com