3.Puttingintooperation/Settings
Self test cycle
After an initial 60-second self-test cycle, the LUXOMAT
®
PD4-DIM/-DUO-
DIM is ready for operation.
Follow-up time for light control
The time can be set infinitely variably at between
1 and 30 minutes. The time-setting is valid for both DIM-Out-
puts of the PD4-DUO-DIM.
Symbol
TEST
: Test mode (Every movement switches on the
light for a period of 1 second, switching it off for a period of
2 seconds after that regardless of the level of brightness)
Twilight-switch for light control (relay 1)
The switch-on value for the light can be set at between 40
and 2000 Lux. Using the rotary control, the luminance set
points can be set as desired.
Symbol :
Night-time operation
Symbol : Daytime/Night-time operation
Orientation lighting (only PD4-M-DIM)
This rotary controller serves to determine the working time of
the orientation lighting (fixed to 20 %).
“ON” for permanent orientation lighting.
“OFF” for deactiviation of orientation lighting.
Installation and Operating Instruction for B.E.G. - Occupancy detectors PD4-M-DIM and PD4-M-DUO-DIM
A circular opening of diameter 68 – 70 mm
must be produced in the ceiling. Having
connected up the cables in accordance
with regulations, the detector is inserted
into the opening as shown in the drawing
opposite and fixed into position with the
assistance of the spring clips.
2a.InstallationoftheLUXOMAT
®
PD4-DIM-SM
2d.Installationofthe
LUXOMAT
®
PD4-DIM
andPD4-DUO-DIM-FM
The detector can be installed in
conventional inlet-sockets mounted on
the ceiling.
The assembly plate enclosed must be
stripped off prior to installation and
secured to the ceiling using 4 screws
and ensuring that it flat. Having con-
nected up the cables in accordance
with regulations, the detector can be
placed in position as shown in the
drawing opposite and, applying a
little pressure, can then be locked into
position with the assistance of the
spring clips.
(Please refer to the connection
diagrams)
2c.InstallationoftheLUXOMAT
®
PD4-DIMandPD4-DUO-
DIM-FC
The detector must be installed on a solid and
level surface. The circular cover ring must be
removed prior to assembly. To do this, twist the
lens (C) anticlockwise through approximately 5°
and lift off.
Having connected up the wires in accordance with
regulations, secure the detector with 2 screws.
After installation replace the lens and lock (turn
clockwise). Mains to be connected
.
Unlocking device
Lock device
4.Settingscarriedoutusingremotecontrol(optional)
Remote control LUXOMAT
®
IR-PDim
1. Check Battery:
open battery compartment by pressing the
plastic springs together and removing the
battery-holder.
2. IMPORTANT
Please pay attention, that the setting is Potentio-
meter 1 at “TEST” and Potentiometer 2
not
at
“SUN”. All values which have been program-
med using the remote control will be deleted
in the event of power failure in the position
“TEST/SUN”. Please switch Potentiometer 2 over
to “MOON” or any other value.
Caution:
Settings with remote control supersede the
settings by courtesy of potentiometers.
LUXOMAT
®
PD4-DIM/-DUO-DIM
1.Mountingpreparations
Work on the 230 V mains supply
may only be carried out by qualified
professionals or by instructed persons
under the direction and supervision
of qualified skilled electrical person-
nel in accordance with electrotechni-
cal regulations.
Disconnect supply before installing!
When in Master/Slave mode of
operation, the Master-appliance
must always be installed at the
location where there is least
daylight.
Luminance set point for constant light regulation
Dimming
The following approach will prove useful when setting a
command value (example workplace): Place a luxmeter flat
on the desk, then, using the remote control IR-PDim, adjust
the light up or down by pressing the keys max or min until
the desired command value which best suits your require-
ments has been reached.
Automatic reading in the current light value
as new luminance set point
Individual light value 2 - 2500 Lux
Follow-up time
1 upto 30 min.
Orientation lighting and its follow-up time
OFF button:
No orientation light
Grey button:
Programming the switch-off delay time
On button:
Orientation light is permanently activated.
Note:
During the orientation light phase, the constant light
regulation is also active: if there is sufficient brightness,
dimming occurs < 2 V and, if applicable, the lighting is
switched off.
Preset/user mode => (see page 2, point 6)
Fully automatic/semi automatic mode => (see page 2, point 5)
Semi automatic: green LED,
Fully automatic: red LED on for ca. 3 sec.
Resetting when open
All values which have been programmed using the remote
control IR-PDim are deleted, and those values which have
been set by potentiometer are activated.
Lock device
Test mode
Reset to deactivate
Resetting when closed
The lighting relay is switched off, i.e.
opened and the follow-up times reset.
Permanent protection against sabotage
This function blocks the unit permanently (green LED is illuminated).
This operating mode can only be activated during the period of 5
seconds after pressing the “lock“ button. This status will only
permit actuating the function “Light on/Light off”.
The procedure for leaving this mode is as follows:
1. Switch off the current
2. Apply current for 31 - 59 seconds
3. Switch of the current again
4. Apply current
5. Open detector
Light on/off
The light will remain switched on/off for as long as movements
are detected in the areas of coverage. Once the last movement
has been detected, the light will remain on for the duration of the
follow-up time as per setting.
The appliance will then return independently to the mode selected
(Fully or Semi-automatic).
2b.InstallationoftheLUXOMAT
®
PD4-DUO-
DIM-FMwithsocketforSurfaceMounting
Before mounting the base, the
enclosed mounting plate must
be mounted true to side, i.e.
the writing must be legible.
Now fix the base on ceiling
or wall, but first put the cable
through one of the cable
openings provided.
The detector must be mounted
on a flat, solid surface.
Next prepare the sensor part by screwing in
both fixing screws according, then connect the
cable. Now insert the sensor part. Press beyond
the spring housing pressure so that the sensor
part firmly locks in place.
Option:
Wall bracket for remote
control IR-PDim
B.E.G.(UK)Ltd.
Q West
Great West Road
Brentford, Middlesex
TW8 0GP
Tel:
0870.850 5412
Fax:
0870.850 5413
E-Mail: [email protected]
Internet: www.beg-luxomat.com
B.E.G.BrückElectronicGmbH
Schlosserstr. 30
51789 Lindlar
Tel:
02266.90 12 10
Fax:
02266.45 092
E-Mail:
Internet: www.beg-luxomat.com
close
open
C
25 22
18
16
10
3
1
TEST
6
30
R1
120 6050
40
30
15
10
A
16 10
5
2
1
30
15
TEST
2000
1200
600
200
40
5
60
5
10
30
50
ON
OFF
1
1
2
2
25 22
18
16
10
3
1
TEST
6
30
R1
120 6050
40
30
15
10
A
16 10
5
2
1
30
15
TEST
2000
1200
600
200
40
5
25 22
18
16
10
3
1
TEST
6
30
R1
2000
1200
600
200
40
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
20 %
max
50
Lux
1500
Lux
ON
OFF