background image

22. PD4-M-2C-SM – Connections

20. Wiring diagram

M

A

N 6

91

– 3

10

713

–4

Standard operation Master/Slave

M1 = HVAC function

Optional 

T1 = NO-button for semi automatic mode;

Extension of the detection area with Slave-devices

22. LED function displays

PD4-M-2C new

M = HKL Funktion
optional
T1 = NO Taster für Halbautomatikbetrieb
Slave zur Erweiterung des Erfassungsbereichs

Master

Slave

Übersicht

L

N

NO

L

N

C1

N L

R

S

NO

C2

T1

E1

M1

R

22. PD4-M-2C-FC – Connections

22. PD4-M-2C-FM – Connections

LED function indicators after each mains recovery (60 sec. initialisation period)

Operating state

LED function indicators

Factory program 

active

White, red and green flash in quick succession for 10 sec., then initialisation indicators, 

see below

Double-locked

white and green shines for 5 sec. all 20 sec., afterwards initialising notification

Indicator  

unprogrammed

Indicator  

programmed

Indicator also when forced shutdown 

is activated

Standard mode

Red flashes

Red flashes quickly

Every 5 sec., 4 x white, red and green 

in quick succession

12 h ON/OFF 

active

Red and green 

flash

Red and green flash 

quickly

Every 5 sec., 4 x white, red and green 

in quick succession

Corridor active

Red and white 

flash

Red and white flash  

quickly

Every 5 sec., 4 x white, red and green 

in quick succession

12 h ON/OFF & 

corridor active

Red, green and 

white flash

Red, green and white flash 

quickly

Every 5 sec., 4 x white, red and green 

in quick succession

CdS active

Red and white flash

Then no red LED for motion detection

LED function indicators during operation

Process

LED function indicators

Motion detection

Red flashes on each detected movement

Semi-automatic mode 

active

White is ON

Impulse active

Red and green flash one time all 4 sec.

Corridor active

White ON 1 sec. and OFF 4 sec.

Corridor and 

semi-automatic mode 

active

White ON 4 sec. and OFF 1 sec.

Too bright detected

Green flashes

Light measurement 

active

Green flashes once every 10 sec.

12 h ON/OFF func-

tion active

Red and green flash alternately

Duration ON active  

(by slave)

Red flashes quickly

IR command

White flashes once

IR command „Open“ 

and sabotage active

White and green flash once slowly

Sensor and power supply in one case

Power supply:

   

230 V~ ±10 %

Power consumption:

  

< 1W

Ambient temperature:

  

-25°C to +50°C

Degree of protection /class:

  IP20 / II 

Settings:      

 

 

Potentiometer, DIP-switch 

and by remote control

Light values:

  

20 - 1000 Lux (with remote control) 

10 - 2000 Lux (with potentiometer)

Extension of the detection area:

 with Slave-devices

Area of coverage:

  

circular 360°

Range of coverage Ø H 2,50 m / T = 18°C:

 

 

seated 6.40 m / tangential 24 m / radial 8 m

Recommended height for mounting:

 2 - 3 m

Light measurement:

  

mixed light, da artificial light

• Channel 1 for light control

Type of contact:

  NOC/with pretravel tungsten contact

Contact load:

      

 2300 W  cos

ϕ

=1 / 1150 VA 

cos

ϕ

= 0.5, µ-Contact

Time-settings:

  

5 sec. - 16 min./ test with potentiometer 

5 min. - 30 min./ test with remote control

•  Channel 2 for control devices  

(only reacts on motion)

Contact load:

    

230 V~, 3 A cos

ϕ

=1 

Time-settings:

 5 min. - 120 min. with time delay of  

5 min. for follow-up time > 15 min./ Alarm impulse

Dimensions H x Ø [mm]:

  

 

PD4-M-2C        SM          FC           FM 

                  76 x 101  97 x 103  84 x 97

Visible portion when built into ceiling FC:

  34 x 10 mm

Technical data PD4-Slave

Power supply:   

230 V~ ±10 %

 

Impulse output:  

Optocoupler max. 2 W

Impulse duration:  

2 sec. or 9 sec.

Dimensions:    

see above

 

Declaration of Conformity: 

The product complies 

with the low voltage recommendation 2006/95/EC 

and the EMV recommendation 2004/108/EC.

19. Technical data PD4-Master-2C

Wiring diagram

  

PD4-M-2C-SM

Wiring diagram

  

PD4-M-2C-FC

Wiring diagram

  

PD4-M-2C-FM

L

N

R

Slave

L'

L

NO NO

S

N N

R

T1

M1

E1

L

N

R

Slave

L'

L

NO NO

S

N

R

T1

M1

E1

L

N

R

Slave

L'

L

NO NO

S

N

R

T1

M1

E1