background image

Sensor and power supply in one

Power supply:

  

230 V~ 

±

10 %

Power consumption:

  

< 1W

Ambient temperature:

  

-25°C to +50°C

Degree of protection/class:

   IP20 / II 

Settings:  

by remote control

Light values - IR-PD4-GH:

   10 - 2000 Lux

Extension of the detection area:

 

 

with Slaves

Area of coverage:

  

circular 360°

Range of coverage Ø H 10 m / T=17°C:

 

 

44 m tangential 

Recommended height for mounting:

 

 

2 - 10 m

Light measurement:

  

daylight and artificial light 

Lux values:

  

10 - 2000 Lux

• Relay/Channel 1 for light-connection

Type of contact:

  

 NOC/with pretravel tungsten 

contact

Contact load:

  

 2300 W cos

ϕ

=1 / 

1150 VA cos

ϕ

= 0.5, µ-Contact

Time-settings:

  

 15 sec. - 30 min. / Test / 

Impulse

Dimensions H x Ø [mm]:  

98 x 65

TechnicaldataPD4-Slave-GH

Power supply:

 

230 V~ 

±

10 %

Impulse output:

  

Optocoupler max. 2 W

Impulse duration:

  

2 sec. or 9 sec.

Dimensions:

 

see above

 

Declaration of Conformity: 

The product complies with 

the low voltage recommendation 2006/95/EC and the 

EMV recommendation 2004/108/EC.

9.TechnicaldataPD4-Master-1C-GH

Type

SM

PD4-M-1C-GH (Master)

92245

PD4-S-GH (Slave)

92265

LUXOMAT

®

 Remote control:

IR-PD4-GH (incl. wall bracket) 

92215

IR-PD-Mini 

 

92159

Accessory:

BSK Ball basket guard 

92199

Wall bracket for remote control  

as replacement 

 

92100

IP54 Socket 

 

92161

12.Article/Partnr./Accessory

M

A

N 6

70

– 

12

09

11

–3

13.LED-functionalindicators,fault-

finding

The functional indicators in the case of the 

LUXOMAT

®

 PD4-M-1C-GH (red and green LED‘s) 

Red and green LEDs for display of the selftest cycle  

(For 60 seconds after the power is switched on)

Red and green LEDs flash 1x per second 

EEPROM/memory empty

Red and green LEDs flash 2x per second 

EEPROM/memory written

Red LED as status display 

Red LED flashes irregularly

 

Movements are detected in the detection area

Red LED flashes 2x per second 

 

Detector detects brightness, light off  

(depending on the operating mode)

Red LED does not light up

Detector detects darkness, light on  

(depending on the operating mode)

Red LED as acknowledgement for commands 

from the remote control

Red LED lights up for 1 second

Valid signal received

Red LED lights up for 0.25 seconds

Command not accepted, detector is locked

Red LED flashes extremely quickly

Command not accepted, for example if twilight value 

is too light or too dark

Red and green LED as acknowledgement 

for commands from the remote control

Red and green LEDs flash 3x briefly every 5 seconds

Indicates semi-automatic mode

Red and green LEDs light up alternately

Determining the light value for automatic shutdown 

with sufficient daylight. (This is only indicated with a 

set lag time of 30 minutes.)

8.RangeofCoverage

11.PD4-M-1C-GH-Connections

6.Fully / Semiautomaticmode

(

for IR-PD functions see page 1

)

 

Fully automatic operation

In this operating mode, the lighting switches automati-

cally on and off for increased comfort, depending on 

presence and brightness.

Semiautomatic operation

(Semiautomatic can only be activated via  

the remote control!)

In this operating condition, in order to gain increased 

savings, the lighting is energized only after being manu-

ally switched on. Switch-off takes place automatically.

The semiautomatic mode basically behaves like the fully 

automatic one. However, the difference is that switching-

on must always be carried out manually!

After automatic shutdown, motion detection is active for 

15 seconds in semi-automatic mode.

As many (closer-contact) buttons as desired can be wired 

in parallel on the “S” button input (ON/OFF).

7.ManualSwitching

 

(A) 

To switch the light on and off, press the button 

briefly. The light remains switched on or off for as long 

as people are detected plus the set lag time.

(B) 

If the “Light stop” function was activated in the selftest 

cycle, the light remains off for 5 seconds after shutdown 

(red and green LEDs flash). Then the automatic function 

is active again.  

HA

ON

HA

OFF

44 m

360°

9.00 m

24 m

max

50

Lux

1500

Lux

ON

OFF

10.Wiringdiagrams

Standard mode with master 1-channel occupancy  

detectors (NO) with R and S terminal

















 









Optional 

T1 = NO-button for semi automatic mode;

Extension of the detection area with Slave-devices

L

N

R

Slave

L

L

NONO

S

N

R

T1

E1

Отзывы: