background image

2. SAFETY INSTRUCTION

Switch off the router when travelling by plane. Use of the router in a plane may endanger the
operation of the plane or interfere with the mobile telephone network, and may be unlawful.

When using the router in the close proximity of personal medical devices, such as cardiac
pacemakers or hearing aids, proceed with heightened caution.

The router may cause interference when in the close proximity of tv sets, radio receivers or
personal computers.

It is recommended to create an appropriate copy or backup of all the important settings that
are stored in the memory of the device.

2.2

Product Disposal Instructions

The WEEE (Waste Electrical and Electronic Equipment: 2002/96/EC) directive has been

introduced to ensure that electrical/electronic products are recycled using the best available
recovery techniques to minimize the impact on the environment. This product contains high
quality materials and components which can be recycled. At the end of its life, this product
MUST NOT be mixed with other commercial waste for disposal. Check the terms and condi-
tions of your supplier for disposal information.

3

Содержание spectre 3g

Страница 1: ...Cellular and Wired Routers SPECTRE LTE 3G RT USER S MANUAL ...

Страница 2: ... does not represent a commitment on the part of B B Electronics Mfg Co Inc B B Electronics Mfg Co Inc shall not be liable for incidental or consequential damages resulting from the furnishing performance or use of this manual All brand names used in this manual are the registered trademarks of their respective owners The use of trade marks or other designations in this publication is for reference...

Страница 3: ...rs 12 5 2 Status Indicators 13 5 2 1 Expansion Port Status Indicators 14 Ethernet Ports 14 RS 232 Ports 15 I O Ports 15 RS 485 422 Ports 15 Wi Fi 15 SmartMesh IP 15 5 3 Power Connector 16 5 4 Antenna Connector 17 5 5 SIM Card Reader 18 5 6 Ethernet Port 18 5 7 Port 1 19 5 8 Port 2 19 5 9 USB Port 20 5 10 I O Port 20 5 11 Expansion Ports Information 22 5 11 1 RS 232 Ports 22 5 11 2 RS 485 422 Ports...

Страница 4: ...ut Output Connector 28 MODBUS ASCII Configuration and Address Space 29 6 Reset or Reboot 36 7 First Use 37 7 1 Starting the Router 38 7 2 Configuring the Router 38 Configuration over Web browser 38 Configuration over Telnet or SSH 39 8 Technical Parameters 40 9 Troubleshooting 45 9 1 FAQ 45 10 Customer Support 46 iii ...

Страница 5: ...ut and output of router 21 21 RS 232 port connector 22 22 Meter connection to router 22 23 Jumper position for external power supply left and internal power supply right 23 24 Jumper position for RS 485 left and for RS 422 right 23 25 RS 485 422 connector 24 26 RS 485 Connection to the router with data cable length less than 10 m 24 27 RS 485 Connection to the router with data cable length more th...

Страница 6: ... Connection of power connector 16 15 Ethernet connector 18 16 Connection of USB connector 20 17 I O port connection 20 18 Connection of RS 232 connector 22 19 Connector pinout in RS 485 mode 24 20 Connector pinout in RS 422 mode 25 21 12 bit Input Output connector pinout 28 22 MODBUS input output address space 35 23 Ways to reset or restart the router 36 24 General specifications 40 25 SPECTRE LTE...

Страница 7: ...ail to support bbelec com Router Version The properties and settings associated with the cellular network connection are not available in noncellular SPECTRE RT routers PPPoE configuration is only available on SPECTRE RT routers It is used to set the PPPoE connection over Ethernet Declared Quality System This device complies with part 15 of the FCC Rules Operation is subject to the following two c...

Страница 8: ...closure suitable for the environment The router must be used in compliance with all applicable international and national laws and in compliance with any special restrictions regulating the use of the router in prescribed applications and environments To prevent possible injury and damage to appliances and to ensure compliance with all rele vant provisions use only the original accessories Unautho...

Страница 9: ...ers It is recommended to create an appropriate copy or backup of all the important settings that are stored in the memory of the device 2 2 Product Disposal Instructions The WEEE Waste Electrical and Electronic Equipment 2002 96 EC directive has been introduced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimize the impact on the envi...

Страница 10: ...endent upon the specific router model Configuration of the router may be done via a password protected Web interface The router supports the creation of VPN tunnels using IPsec OpenVPN and L2TP to ensure safe communication The Web interface provides detailed statistics about the router s activities signal strength etc The router supports DHCP NAT NAT T DynDNS NTP VRRP control by SMS and many other...

Страница 11: ...Package 3 4 Model Numbers Standard Features on SPECTRE Routers 10 100 Ethernet USB Host Port Binary I O Port Dual SIM Card slots Expansion Port Functions Model Dependent The Ports Can Be Connected As Follows PORT 1 ETHERNET SWITCH together with PORT 2 RS 232 RS 485 422 12 bit I O AI DI DO PORT 2 SWITCH together with PORT 1 RS 232 RS 485 422 Wi Fi SmartMesh IP Table 1 Expansion port possibilities 5...

Страница 12: ... I O AI DI DO Wi Fi RTLTE 340 W VZ RS 422 485 Wi Fi RTLTE 350 VZ No connect SmartMesh IP RTLTE 351 VZ Ethernet SmartMesh IP RTLTE 352 VZ RS 232 SmartMesh IP RTLTE 354 VZ RS 422 485 SmartMesh IP Table 2 SPECTRE LTE model numbers for Verizon SPECTRE LTE Wireless Routers AT T Expansion Ports Model No Port 1 Port 2 RTLTE 300 AT No connect No connect RTLTE 302 AT No connect RS 232 RTLTE 304 AT No conne...

Страница 13: ...xpansion Ports Model No Port 1 Port 2 RT3G 300 No connect No connect RT3G 302 No connect RS 232 RT3G 304 No connect RS 422 485 RT3G 310 Ethernet No connect RT3G 311 Ethernet SWITCH Ethernet SWITCH RT3G 312 Ethernet RS 232 RT3G 314 Ethernet RS 422 485 RT3G 322 RS 232 RS 232 RT3G 324 RS 232 RS 422 485 RT3G 330 12 bit I O AI DI DO No connect RT3G 300 W No connect Wi Fi RT3G 310 W Ethernet Wi Fi RT3G ...

Страница 14: ...o Port 1 Port 2 ERT310 Ethernet No connect ERT311 Ethernet SWITCH Ethernet SWITCH ERT312 Ethernet RS 232 ERT314 Ethernet RS 422 485 ERT351 Etherent SmartMeshIP Table 5 SPECTRE RT Ethernet Router 3 5 Dimensions Basic dimensions metal box Figure 2 Basic dimensions metal box 8 ...

Страница 15: ...guidelines When using the supplied whip antennas maintain a distance of 6 cm from cables and metal surfaces on every side When using an external antenna unless in a switch board it is necessary to fit a lightning conductor When mounting a router on sheet steel we recommend using an external antenna If the router is installed in a metal instrument enclosure an external antenna must be used and it m...

Страница 16: ... length of the data cables exceeds 1 5 meters or if the cable leads towards the switch panel we recommend installing overvoltage protectors surge suppressors 3 Do not bundle the data cables with 120 230V power cables 4 All wiring to sensors should use shielded twisted pairs Figure 4 Cable routing Leave enough space around the connectors for the handling of cables Figure 5 Space in front of connect...

Страница 17: ...pply data cables and antenna Removing from DIN rail Figure 6 DIN rail clip This is the default position of the DIN rail clip To remove the router from the DIN rail push the router up slightly so that the top part of the clip disengages and then gently slide the router off the DIN rail Figure 7 Removing the router from the DIN rail 11 ...

Страница 18: ...els only DIV SMA Diversity cellular antenna LTE models only GPS SMA GPS antenna LTE models only AUX SMA RP SMA 3G models on the left DIV GPS all models on the right SmartMesh IP antenna WIFI RP SMA Wi Fi antenna LTE and 3G models only USB USB A Host USB connector I O 3 pin Binary input and output SIM SIM card holder LTE models only SIM1 SIM card holder 3G models only SIM2 SIM card holder 2 3G mode...

Страница 19: ...SPECTRE RT front panel example model ERT311 5 2 Status Indicators Caption Color State Description PWR Green Blinking On Fast blinking Router is ready Starting of the router Updating firmware DAT Red Blinking Communication in progress on radio channel To be continued on the next page 13 ...

Страница 20: ... Selected 10 Mbit s ETH Yellow On Blinking Off The network cable is connected Data transmission The network cable is not connected PORT Green LED functions for different router configurations appear in the charts below PORT Yellow LED functions for different router configurations appear in the charts below SIM Yellow On SIM card is active LTE models only SIM1 Yellow On SIM card 1 is active 3G mode...

Страница 21: ...y input 1 Table 10 I O Port LED status indication RS 485 422 Ports LED Port Indicator Green LED Blinks on Receive data Yellow LED Blinks on Transmit data Table 11 RS 232 LED status indication Wi Fi LED Port Indicator Green LED Indicates Wi Fi Power On Yellow LED Always Off Table 12 Wi Fi LED status indication SmartMesh IP LED Port Indicator Green LED Indicates SmartMesh IP Power On Yellow LED Alwa...

Страница 22: ...ly Protection against reversed polarity is built into the router The power consumption in receive mode is 2 3 W LTE models or 2 6 W 3G models The peak power consumption during data sending or communication running on RT models is 5 5 W For correct operation the power source must be able to supply a peak current of 1 A The power cable connects to the router via locking screws See figure below Figur...

Страница 23: ...s SPECTRE 3G There are always connectors AUX and DIV for main antenna and diversity GPS antenna the GPS mode is chosen internally by activating the GPS User Module in the router There can be antenna connector in the middle based on the model number WIFI antenna connector RP SMA for Wi Fi models and another AUX connector RP SMA for SmartMesh IP models SPECTRE RT There is not any antenna connector a...

Страница 24: ...ower supply before handling the SIM card Press the small button on the right hand side of the SIM reader slot to eject the SIM card holder Insert the SIM card into the holder and slide it in the reader See figure bellow Figure 15 Ejected SIM card holder 5 6 Ethernet Port Panel Socket RJ45 Pin Number Signal mark Description Data Flow Direction 1 TXD Transmit Data positive pole Input Output 2 TXD Tr...

Страница 25: ...ogether with PORT 2 serial communications RS 232 see chapter 5 11 1 and RS 485 422 see chapter 5 11 2 12 bit I O AI DI DO see chapter 5 11 3 5 8 Port 2 Based on the model number see chapter 3 4 the expansion PORT 2 may be configured for SWITCH together with PORT 1 serial communications RS 232 see chapter 5 11 1 and RS 485 422 see chapter 5 11 2 Wi Fi connector PORT2 used for indication only see ch...

Страница 26: ...igure 18 USB connector 5 10 I O Port 3 Pin Panel Socket Pin No Signal mark Description Data Flow Direction 1 BIN0 Binary input Input 2 GND Signal ground 3 OUT0 Binary output Output Table 17 I O port connection Figure 19 I O connector The user interface I O is for the processing of binary input signals and for control settings of binary output signals Binary output is not switched to ground in the ...

Страница 27: ...ES Connect the cable s I O connector to the router s I O port and tighten locking screws Circuit example of a binary input or output connected to the router Figure 20 Connection of binary input and output of router 21 ...

Страница 28: ...2 port is protected against bus overload Figure 21 RS 232 port connector Panel socket RJ45 RS 232 DCE Data Communication Equipment Pin Signal Description Direction 1 RTS Request To Send Input 2 CTS Clear To Send Output 3 DTR Data Terminal Ready Input 4 DSR Data Set Ready connect to 3 V through R 330 Ohm Output 5 GND Signal ground 6 TXD Transmit Data Output 7 CD Carrier Detect Output 8 RXD Receive ...

Страница 29: ... J5 and J6 on the RS 485 module select the mode of the port either RS 485 or RS 422 mode If RS485 is required jumpers J4 and J5 must be connected and jumper J6 disconnected If RS422 is required jumpers J4 and J5 must be disconnected and jumper J6 connected Jumper placement can be seen in the pictures below RS 485 module is viewed from the top Internal power supply should only be used in the event ...

Страница 30: ...TxRx RS485 B Input Output 6 TxRx RS485 A Input Output 7 12 V EXT External power supply 8 12 V EXT External power supply Table 19 Connector pinout in RS 485 mode ATTENTION The power supply is selected on the module board using the jumpers In RS 485 mode pins 3 and 5 and pins 4 and 6 are internally shorted together If galvanic separation is required the converter must use an external power supply Fi...

Страница 31: ... Pin Signal mark Description Data flow direction 1 SGND Signal and power supply ground 2 SGND Signal and power supply ground 3 RxD Receive data Output 4 RxD Receive data Output 5 TxD Transmit data Input 6 TxD Transmit data Input 7 12 V EXT External power supply 8 12 V EXT External power supply Table 20 Connector pinout in RS 422 mode ATTENTION The power supply is selected on the module board using...

Страница 32: ...on to the router with data cable length less than 10 m Figure 30 RS 422 Connection to the router with data cable length more than 10 m With a RS422 data cable more than 10m long it is necessary to use overvoltage protection on the router side 26 ...

Страница 33: ... The ADC value stored in memory is calculated using the following equation ADC Value 12b value addit constant multiplic constant 1000 where the constants are programmed into memory by the user Binary Input The binary input is sampled 8x per second with a sampling period of 1 64 seconds The active level for each binary input may be set to either a logic 0 or logic 1 The inputs may be configured to ...

Страница 34: ... noise on the input but also dissipates more power Figure 31 Threshold select using jumper on the board Input Output Connector Figure 32 12 bit I O CNT connector Panel socket RJ45 12 bit I O Pin Signal mark Description Data flow direction 1 BIN1 CNT1 Binary input counter input Input 2 BIN2 CNT2 Binary input counter input Input 3 BIN3 Binary input Input 4 BIN4 Binary input Input 5 GND Signal ground...

Страница 35: ...port 1 Using this protocol it is possible to configure the 12 bit I O board read the input status and control the output The I O port communicates at 9600 baud 8 bits no parity and 1 stop bit 8N1 MODBUS input output address space in the table below Address Access Description 0x0000 R Type of firmware 0x0001 R Upper 16 bits of firmware version 0x0002 R Lower 16 bits of firmware version To be contin...

Страница 36: ...f the number of seconds since January 1 1970 0x0007 R W Lower 16 bits of the number of seconds since January 1 1970 0x0008 R W Upper 16 bits of the current log number 0x0009 R W Lower 16 bits of the current log number 0x000A R Current alarm status 0x0100 R Status of the binary inputs 0x0200 R W Status of the binary outputs 0x0300 R Recalculate value of AN1 analogue input with sign 0x0400 R Recalcu...

Страница 37: ...analogue input bit 5 exceeded the upper limit of the AN1 analogue input bit 6 exceeded the lower limit of the AN2 analogue input bit 7 exceeded the upper limit of the AN2 analogue input bit 8 exceeded the limit frequency of CNT1 bit 9 exceeded the limit frequency of CNT2 0x0F05 R Status of the binary inputs bit 0 level at the BIN1 input bit 1 level at the BIN2 input bit 2 level at the BIN3 input b...

Страница 38: ...1008 R 1st log upper 16 bits of CNT1 0x1009 R 1st log lower 16 bits of CNT1 0x100A R 1st log prompt CNT1 frequency 0x100B R 1st log average CNT1 frequency 0x100C R 1st log minimal CNT1 frequency 0x100D R 1st log maximal CNT1 frequency 0x100E R 1st log upper 16 bits of CNT2 0x100F R 1st log lower 16 bits of CNT2 0x1010 R 1st log prompt CNT2 frequency 0x1011 R 1st log average CNT2 frequency 0x1012 R...

Страница 39: ... analogue input bit 8 exceeded the limit frequency of CNT1 bit 9 exceeded the limit frequency of CNT2 0xF100 W Negative logic of binary inputs bit 0 BIN1 input bit 1 BIN2 input bit 2 BIN3 input bit 3 BIN4 input 0xF200 W Normal level of binary outputs bit 0 OUT1 output 0xF201 W Feeder number of pulses at the BIN1 CNT1 input 0xF202 W Feeder pulse length at the OUT1 output 1 8 sec 0xF300 W AN1 sampli...

Страница 40: ...AN2 additive constant with sign 0xF403 W AN2 hysteresis value with sign 0xF404 W AN2 lower limit with sign 0xF405 W AN2 upper limit with sign 0xF406 W Bits 7 3 AN2 switching time of measurement circuit 0 1 64 sec 1 2 64 sec 30 31 64 sec Bits 2 0 AN2 number of samples for averaging 0 one sample 1 two samples 2 four samples 4 eight samples 5 sixteen samples 0xF500 W CNT1 Multiplicative constant 0xF5...

Страница 41: ...Address Access Description 0xF601 W CNT2 Upper limit 0xF602 W CNT2 Time of limit exceeded sec 0xF603 W CNT2 Time for resetting measurement sec 0xFFFF W Turn off the the main source at the specified time min Table 22 MODBUS input output address space 35 ...

Страница 42: ...t the router Press RST button Table 23 Ways to reset or restart the router After the green LED starts to blink you may restore the router s initial settings by pressing button RST on front panel The router will restore its factory default configuration and reboot The green LED will be on To reset use a narrow screwdriver See figure below Figure 34 Router reset We recommend backing up your router c...

Страница 43: ...l need to make all of the necessary connections The router cannot operate without a connected antenna SIM card for UMTS networks and a power supply Operating the router without an antenna can damage the router Figure 35 Connecting the router before the first use 37 ...

Страница 44: ...sioned for the necessary network LTE HSPA UMTS EDGE GPRS For 3G CDMA networks the router is provisioned over the air Refer to the Configuration manual for details on configuring the router based on the cellular carrier and network If the router cannot establish a connection to the cellular network it tries to reconnect The retry interval prolongs with more retries First two retries are done after ...

Страница 45: ...ration of the router can be performed by means of the Telnet or SSH interface The default IP address of the router is 192 168 1 1 The username is root The password is root A detailed description of configuring the router via Telnet or SSH can be found in the Configuration Manual and Commands and Scripts Application Note 39 ...

Страница 46: ...otection IP20 Supply voltage 10 to 30 V DC Class 2 Power Supply Only Consumption No communica tion Receive Mode Transmit GPRS Transmit others 1 6 W RT models 2 3 W LTE models 2 6 W 3G models up to 3 5 W GPRS transmission up to 5 5 W UMTS HSDPA EVDO LTE RT models with communication Dimensions 42 x 80 3 x 113 2 mm DIN 35 mm Weight 280 g Antenna connector SMA 50 Ohm SIM Card Interface 1 8 V and 3 3 V...

Страница 47: ...PRS multislot class 12 CS 1 to 4 MCS 1 to 9 Transmit power LTE 23 dBm UMTS HSUPA HSDPA HSPA Class 3 23 dBm GSM850 CS Class 4 32 dBm GSM900 CS Class E2 27 dBm Supported channels GSM GPRS EDGE 850 900 1800 1900 MHz UMTS HSDPA HSUPA HSPA 800 850 1900 2100 MHz LTE 700 AWS 2100 Mhz GPS Standalone mode Assisted mode A GPS SUPL1 0 1575 42 MHz Protocol NMEA 0183 V3 0 Table 25 SPECTRE LTE AT cellular modul...

Страница 48: ...parameters 3GPP Release 99 GSM GPRS Supported channels HSPA UMTS 850 900 AWS 1900 2100 MHz EGPRS 850 900 1800 1900 MHz CDMA 800 1900 MHz GPS Assisted Mode Table 27 SPECTRE 3G cellular module specifications 32b ARM Microprocessor Memory 512 Mb DDR SDRAM 128 Mb FLASH 1 Mb MRAM Interface Serial interface RS232 Ethernet interface 10 100 Mbit s USB 2 0 interface Table 28 Processor specifications Port I...

Страница 49: ...munity Safety Isolation EN 55022 B ETS 300 342 EN 60950 EN 60747 Wi Fi specifications 802 11 b g n RX Sensitivity TX Output power 11b 11Mbps 11g 54Mbps HT20 11n MSC7 HT20 11n MSC7 11b 11Mbps 11g 54Mbps 802 11n HT20 802 11n HT20 85 dBm 70 dBm 66 dBm 62 dBm 19 dBm 16 dBm 15 dBm 15 dBm Internal Antenna Impedance 50 Ω Frequency band 2 4 GHz Table 30 Wi Fi Specifications 43 ...

Страница 50: ...15 2405 5 k 11 MHz Modulation IEEE 802 15 4 Direct Sequence Spread Spectrum DSSS Raw Data Rate 250 kbps Range 25 C 50 RH 2 dBi Omni Directional An tenna Antenna 2 m above ground Indoor Outdoor 100 m 300 m Receiver Sensitivity Packet Data Error Rate PER 1 93 dBm Receiver Sensitivity PER 50 95 dBm Output Power Delivered to a 50 Ω load High Calibration Setting 8 dBm Low Calibration Setting 0 dBm Tabl...

Страница 51: ...s necessary to set ping which will check the connection and in the case of failed ping restart the connection Q PPP connection cannot be established DAT LED off Recheck GPRS settings APN name password and IP address Try to enter PIN verify if the SIM card has the PIN code set In a private APN switch the DNS server send off Switch the system log on and observe where the error occurs Q FTP doesn t f...

Страница 52: ...ot clean the router with harsh chemicals solvents or abrasive cleaners RT and 3G models B B Electronics hereby declares that the models RT and 3G of the router described in this user s guide fits all basic demands of directive 1999 5 EC R TTE Router fits values of coefficient SAR defined by association ICNIRP and values of About protection of health before non ionized radiation Declaration of conf...