![B+B SmartWorx iMediaChassis/20 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/b-b-smartworx/imediachassis-20/imediachassis-20_user-manual_460637028.webp)
IMediaChassis Series
19
LAST GASP ALARM
The iMediaChassis series includes the Last Gasp trap feature, “Remote Chassis
Down”, which sends a Trap when the following occurs:
• Both power supply modules malfunction
• Both power supply modules are powered down
• When the AC line fails
TEMPERATURE GAUGE
The iMediaChassis/3 includes a temperature monitoring gauge with a heat sensor
on the SNMP Management Module. Users define a threshold for chassis
temperature via SNMP. If the chassis’ temperature rises above the specified level,
the SNMP agent sends a trap (configured in iView²) to the administrator. There is
also an LED indicator on the SNMP Management Module for chassis temperature.
Installing the iMediaChassis/3
Install the chassis first before installing any modules into an iMediaChassis.
When installing the chassis, be sure to observe the following precautions to
prevent electrical or mechanical damage:
1. Stay within the chassis’ power rating to prevent overload of supply circuits or
damage to any overcurrent protection and supply wiring.
2. Maintain reliable ground, especially when connecting to a power strip instead
of directly to a branch circuit.
3. Protect the chassis from exposure to sunlight and electrical or magnetic
fields.
4. Ensure that the equipment rack remains stable, even with the addition of the
chassis and its associated cabling.
Use the iMediaChassis/3 as a table-top chassis, mount on a Rackmount shelf.
To install the 3-slot Rackmount in the chassis:
1. Install the iMediaChassis/3 by placing it on a flat surface.
2. Make sure to leave adequate space on the sides of the unit to accommodate
cooling.
3. If mounting on a Rackmount shelf, align holes of the chassis to the shelf and
secure with screws.