Страница 1: ...IE MultiWay USER MANUAL ...

Страница 2: ...cas 707 Dayton Road Ottawa IL 61350 USA Phone 1 815 433 5100 Fax 1 815 433 5105 Advantech B B SmartWorx Europe Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 www advantech bb com support advantech bb com ...

Страница 3: ...Autocross Feature for Twisted Pair Connections 12 Configuration 13 Configuration Feature Options 13 Configuration Management Options 14 Basic Device Configuration Using the CLI 15 Saved and Current Values 16 Command List 16 Assigning IP Information 16 Password Protection for Serial Port Connections 17 Assigning SNMP Trap Destinations 17 Removing Trap Destinations 17 Creating Community Strings 18 D...

Страница 4: ...Based Extra Tagging 25 Bandwidth bw 25 SFP A B Ports 26 TX1 2 26 Firmware Version 28 Viewing Port Statistics ifstats 28 Viewing Port RMON Statistics rmstats 28 System Description sysDescr 29 Reboot 29 Operation and Administration Management OAM 30 Viewing SFP Statistics sfpstats 30 Unit 31 LFPT 31 Port Configuration Port 32 Branch Leaf 33 Using iView2 33 Unit Configuration 35 Port Configuration 36...

Страница 5: ...nfiguration File with iView2 iConfig View 55 SFP Ports 56 Hardware Wiring Specifications 56 DC Terminal Block Wiring Instructions 56 RJ 45 Data Port Pinout 57 RS 232 Serial Console Port 57 Product Application 58 Specifications 59 Glossary 60 Troubleshooting 62 B B SmartWorx Technical Support 63 Statements Guidelines Precautions 63 FCC Radio Frequency Interference Statement 63 Fiber Optic Cleaning ...

Страница 6: ...mperature range of 40 to 85 C A console port and a DIP Switch bay provide configuration options The IE MultiWay can be managed directly because it contains on board logic iView2 free software and current firmware versions may be downloaded from the B B SmartWorX site under Support The IE MultiWay requires two small form factor SFP modules that provide greater flexibility in the network environment...

Страница 7: ...ned VLAN tag Ethertype 88A8 as defined in 802 1ad Command Line Interface capable CLI TELNET Link Fault Pass Through LFPT Password assignment via CLI Telnet or iView DIP Switch configuration for Modes Bandwidth Limiting L2PT The IE MultiWay can be installed as a standalone CPE device back to back or as a Remote when connected to an iMcV Giga FiberLinX II configured as a Host As a CPE device the IE ...

Страница 8: ...initiate a loopback circuit 802 1ag SERVICE OAM Often referred to as Connectivity Fault Management CFM is an end to end protocol designed to verify a specific network path between two devices that may be in different geographical locations CFM allows the network operator to administer monitor and debug the network using continuity check a heart beat message link trace similar to traceroot but oper...

Страница 9: ...ew MIB information It also includes diagnostic capabilities for faster resolution of technical support issues HARDWARE MOUNTING OPTIONS The IE MultiWay can mount on DIN rail or use a wall mount bracket shown below DIN rail clips part number 806 39105 and wall mount brackets part number 895 39229 are available for purchase from B B SmartWorx The IE MultiWay can be mounted with two DIN rail clips av...

Страница 10: ...tate for testing and line verification but does not actively carry user data When a fault is detected on the active line all customer traffic is switched to the SFP B port With non Revertive mode data is not resumed by SFP A port until SFP B fails or is disconnected 1 1 SFP Protection Revertive mode In this mode the SFP A port fiber or copper is connected through the switch to the drop ports as th...

Страница 11: ...ection with revertive switching OFF 4 LoSpd B Optional for future use OFF 5 LoSpd A Optional for future use OFF 6 Reserved POWERING THE IE MULTIWAY The IE MultiWay includes multiple powering options AC adapter 4 terminal DC power block Optional IE Power 5V DIN rail mount extended temperature power supply Optional double USB power cable SHOWN IE MultiWay with optional DIN rail mount power supply Co...

Страница 12: ...ber when a fault is detected LNK Glows green with a valid optical link ACTIVE Glows green when the port is active OFF when SFP is in standby does not indicate activity OAM Glows green when an active OAM AH channel is established RJ 45 LED functions are as follows LNK ACT Glows green when a link is established on the TX port blinks green when activity is detected on the TX port FDX Glows amber when...

Страница 13: ...NFIGURATION FEATURE OPTIONS The below features are configurable through both iView2 iConfig view and Serial Telnet Feature iView Serial Telnet Loopback Auto Negotiation Force Mode FlowControl VLANs IP Address Subnet Mask Default Gateway MIB Community Traps Assignment Users Passwords Access Level Reboot Frame SizeS Bandwidth Limiting LFPT Link Fault Pass Through Branch Leaf L2PT ...

Страница 14: ...options configurable via iView2 iConfig view or a serial Telnet session Feature iView2 iConfig Serial Telnet PROM Software Download Upload Telnet Session Software Download Setup TFTP DHCP Restore Configuration Save Configuration MACTAB Clear Counters Disable Enable Management on Ports ...

Страница 15: ...creen This screen allows the user to set the IP address and destination IP address for traps with the community string read write access and password as usual Saved Values These values will be active after reboot IP Address 10 10 10 10 Subnet Mask 255 255 255 0 DHCP is Not Active Default Gateway 0 0 0 0 Current Values These values are in use now IP Address 10 10 10 10 Subnet Mask 255 255 255 0 Def...

Страница 16: ...ce specific configuration options screen The screens illustrated in this manual show capabilities for users with Admin rights Individuals with User level rights can only view port status and port settings change their password end a session and reboot the unit NOTE It is necessary to reboot the IE MultiWay after making any modifications to the Saved Values for the changes to take effect To reboot ...

Страница 17: ...rds are a way to make management of B B SmartWorx devices secure but these password lists must be stored and maintained ASSIGNING SNMP TRAP DESTINATIONS Traps are sent by the manageable device to a management PC when a certain event takes place To enter a trap destination press T When prompted enter a New IP Address prompt enter the appropriate IP address of the destination device and press Enter ...

Страница 18: ...strings prompt is displayed Press Y when prompted to proceed and delete all community strings N to abort Press Enter to finish This function will delete ALL community strings To selectively delete community strings use iView2 iConfig view to configure the device ENDING THE SESSION Press E to end a serial port or Telnet HyperTerminal session before disconnecting the serial cable This will stop the ...

Страница 19: ...serial configuration to manually set the IP addresses When DHCP is enabled the IP address default 10 10 10 10 or a previously used IP address or user configured is saved When DHCP is disabled the saved IP address will be reinstated and the device will reboot DHCP servers give out lease times and devices renew their leases based on the administrator specified time If a device cannot renew its lease...

Страница 20: ... Allows a soft reboot of the unit after changes are made by the end user oam Enable disable OAM sfpstats Provides information about the wavelength serial number output power BER and other information Requires an SFP with DDMI unit Unit global settings frame size selection Unit OAM enable must be enabled for AH and AG to function port Displays the port status and allows changes to port settings suc...

Страница 21: ...ion file type download and press Enter to be taken to the Download a file screen This screen displays the IP Address of the TFTP server and the name of the file to be downloaded The TFTP server should be open Press Enter to start downloading the file After the transfer process is complete press Enter to load the configuration file Once loaded into the device s SNMP memory area the system prompts t...

Страница 22: ... then you can enter a VID of your choice TRUNK PORT VS ACCESS PORT A Trunk port allows multiple VLANs to pass between two switches An Access Port allows one VLAN ID assigned a VLAN ID as well as Priority When configuring a trunk port an Ethertype can be user defined a trunk port is also defined as a provider port based on 802 1ad If an Ethertype value comes in a trunk port and is different than th...

Страница 23: ...ONFIGURATION There are two modes of operation that can be configured through the Serial Telnet session Mode 1 supports a mixture of tagged and untagged traffic Mode 2 extra tagging The configuration screen is accessed by typing vlan and pressing Enter from the Additional Commands screen The system displays the current operation mode screen Press the Space Bar to select the other mode ...

Страница 24: ...any given port Management to the device can be tagged or untagged Press the down arrow on the computer keyboard to access additional configuration selections WARNING If a VLAN is added to a port and is the same VLAN assigned for a tag on management traffic saving these changes will disrupt management indefinitely ...

Страница 25: ...PORT BASED EXTRA TAGGING Any port can be configured for extra tags on the frames Press the down arrow on the computer keyboard to access the additional configuration commands BANDWIDTH BW Displays settings for Bandwidth configuration ...

Страница 26: ...ntrols the transmitter and hard limits the maximum frame rate that can be sent Frames can be delayed in the internal buffers of the unit waiting their turn to be sent If the internal buffers are full excess traffic will be dropped The Unit Rate Control can be used to alleviate this TX1 2 Ingress Bandwidth Limit CIR Monitors the traffic entering the unit ingress discarding traffic that exceeds a fi...

Страница 27: ...rt also has Flow Control enabled this ensures packets will not be dropped OSI NOTE The Bandwidth Limit functions can be adjusted to only count the Layer 1 2 or 3 portions of the physical line rate Layer 1 is used to relate Bandwidth to the physical line rate where a 100BaseT Ethernet line can carry a MAX bandwidth of 100Mbps Layer 2 may be more useful when the Ethernet Frame may be carried over se...

Страница 28: ...n the IE MultiWay enter ifstats This will open a screen displaying information on packets received and transmitted as defined by MIB II standard RFC 1213 Pressing the Space Bar will refresh the data on the screen VIEWING PORT RMON STATISTICS RMSTATS To view port RMON Remote MONitoring statistics on the IE MultiWay enter rmstats This displasy RMON information on packets received as defined in RFC 2...

Страница 29: ... to enter a description for the B B SmartWorx device Within the iView GUI a name or some kind of identifier can be entered into the text box labeled Description Once that description is saved the identifier will be maintained even if power is interrupted to the unit REBOOT Entering reboot will save settings and reboot the IE MultiWay ...

Страница 30: ...SFP ports and TX ports Supports Discovery functions on the SFP ports Supports reporting OAM Flag Events Link Fault Critical Event Dying Gasp Supports Loopback VIEWING SFP STATISTICS SFPSTATS To view SFP statistics on the IE MultiWay enter sfpstats This will open a screen displaying SFP information including vendor serial number bit rate and other options Pressing the Space Bar to refresh data on t...

Страница 31: ... FlowC to Advertise Flow and set Force FlowCtrl to Frc FlowCt Unit FlowControl This enables disables FlowControl functionality on the unit and must be enabled for FlowControl to function on any port LFPT Link Fault Pass Through is a diagnostic feature that allows troubleshooting by enabling it The feature allows both end segments of the conversion to detect link faults occurring in the media conve...

Страница 32: ...Status Set Administration level Select UP to enable management through the port Both settings must be enabled to enable the port Port Speed Ctrl Set the port manually or for Auto Negotiation Advertise Ctrl This is the Selective Advertising feature Selective Advertising when used in combination with Auto Negotiation advertises the configured speed and duplex mode for the twisted pair ports Auto Neg...

Страница 33: ...indows SNMP services must be installed to receive traps The autoscan feature of iView will detect B B SmartWorx devices on an active subnet and list them in the network outline Click the connection for the IE MultiWay to open its iView screen To perform additional configuration select the iView2 iConfig view icon on the toolbar in iView This allows a session to be launched and the default password...

Страница 34: ...andwidth Displays settings for bandwidth configuration Statistics Display statistics tables including unit and port tables RMON statistics MIB II ifTable and SFP Info VLAN Provides configuration for VLAN IDs per port OAM AH Configure passive and active 802 3ah OAM CFM Perform administrative configuration functions Agent Info Displays SNMP agent data Refresh Soft reboot to the system ...

Страница 35: ...ation to display modify unit information including IP address display only modification not allowed global flow control maximum frame size and OAMPDU NOTE Entering a descriptor in the Description field can make it easier to track down the source of a Trap ...

Страница 36: ...ncluding description and flow control BRANCH LEAF This option allows the end user to ensure that ports cannot directly talk to one another One port must be selected to be the Branch and at least two other ports as a Leaf Each Leaf port can talk to the Branch but cannot directly talk to each other ...

Страница 37: ...IE MultiWay 37 BANDWIDTH Select Bandwidth to display configure bandwidth settings for each port ...

Страница 38: ...IE MultiWay 38 STATISTICS Select Statistics to display a screen and select specific statistics to view Select Statistics to access the SFP table to display the following information ...

Страница 39: ...ossible priority settings are 0 lowest priority through 7 highest priority This screen also allows you to set up each port as a Trunk or Access port A Trunk port will allow multiple VLANs to be transported An Access port will allow one VLAN to be transported ...

Страница 40: ...the cloud to become transparent to the protocols Firmware version B0 supports this feature L2PT is enabled on a per port basis in VLAN mode 2 In this mode ports are defined as either Trunks or Access Access ports have a switch that enables disables L2PT WARNING If a VLAN is added to a port and is the same VLAN assigned for a tag on management traffic saving these changes will disrupt management in...

Страница 41: ...IE MultiWay 41 AGENT INFO Select Agent Info obtain data on IP address firmware version and other info ...

Страница 42: ...IE MultiWay 42 OAM AH Select OAM AH to display the following screen and monitor the status configuration loopback event log and statistics ...

Страница 43: ...IE MultiWay 43 From the above screen select Configuration to display state and event configuration information as well as OAM supported functions ...

Страница 44: ...mands Only AH Active units can send a Loopback command to a remote unit Either Active or Passive AH units can respond to a Loopback command but must be configured to process these commands or they will be ignored Select Loopback to display loopback data and define how loopback is configured Select Event Log to display the OAM event log showing fault changes that have occurred via OAM configuration...

Страница 45: ...IE MultiWay 45 Select Statistics to display OAM statistics ...

Страница 46: ...MAs and Maintenance Association End Points MEPs The page contains a list of the local MEPs and provides menu controls to access the administrative functions associated with Create Delete and List MD MA and MEP information An example of a default OAM CFM Configuration page is shown below The OAM CFM Configuration page defaults to the Configure MEP selections ...

Страница 47: ...ure MD button to display the OAM CFM Maintenance Domain Configuration page as shown below NOTE iView2 will automatically display this page if there is no MD yet defined when the user attempts to access any other menu control Enter the MD name and select the level for the domain To cancel the MD select Delete To store the MD press Save and the screen is refreshed ...

Страница 48: ... attempts to access any other menu control Select the Domain and Format and enter the MA name in the Name field Use Interval to select the interval for continuity check messaging and choose Primary VID if applicable To cancel the MA without saving select Delete To store the MA select Save and the screen is refreshed For a first time configuration the next step is to create a MEP Select Add New MEP...

Страница 49: ...d configuration To access a particular instance of an MEP click on the row containing the desired MEP as shown below The current state of the MEP is shown by the color in the State column Color Description Green Correctly functioning MEP all MEPs are active and sending CCMs Red Idle state or problem associated with the MEP Yellow Not all peer MEP CCMs are being received Moving the mouse over the d...

Страница 50: ...escription Continuity Check Enable disable CCMs and verify the number of CCMs that have been sent Instance State Details Verify the current administrative state of the MEP view the last defect identified by the MEP and view the MAC address of the MEP Peer MEPs Create List Delete Peer MEPS associated with the MEP Loopback Activate loopback and see the results of loopback operations ...

Страница 51: ...cV Giga FiberLinX II or iMcV Giga FiberLinX III iView2 provides support for SNMP management of the pair Several pairs can be managed via UMA through the SNMP management module on the same IP address For information or instructions on the use of Unified Management Agent UMA refer to the SNMP Management module manual available on the B B SmartWorx website ...

Страница 52: ...s configurations and SNMP agent settings The configuration file can be transferred from the unit to a PC and saved to disk via the iView2 iConfig view protocol The configuration file can be transferred from a PC to a unit of the same type via iView2 iConfig view or TFTP into the unit s Large File Area After the transfer is complete the unit copies the configuration to flash and reboots The configu...

Страница 53: ...IE MultiWay 53 The user is prompted for a filename Once the file is selected the end user can press the button labeled Release Notes and read all enhancements bug fixes for the binary release ...

Страница 54: ...IE MultiWay 54 After the file is uploaded the end user will get a dialog box confirming the upgrade was successful ...

Страница 55: ...TH IVIEW2 ICONFIG VIEW From the Administration Tab in iView2 iConfig view click the Upload Configuration button The user will be prompted to select a configuration file Once selected the user can also view any notes that were added when the file was saved ...

Страница 56: ... SFPs in 10 100 1000Mbps and 1000Mbps DDMI statistics provide real time access to transceiver operating parameters such as voltage temperature laser bias current and both transmitter and receive optical power This information can be accessed via the management system SFPs must be MSA compliant available from B B SmartWorx or other suppliers HARDWARE WIRING SPECIFICATIONS DC TERMINAL BLOCK WIRING I...

Страница 57: ... duplex mode RS 232 SERIAL CONSOLE PORT The IE MultiWay includes an RS 232 mini jack for the Console port allowing the end user to launch a serial session and access a list of commands The serial port on the computer terminal should be set for 38 4K baud 8 data bits 1 stop bit no parity no flow control The F2 key functions as a Delete key on VT 100 emulators The following table lists the pin confi...

Страница 58: ...IE MultiWay 58 PRODUCT APPLICATION ...

Страница 59: ... USB Power Cable Spec 500mA NOTE the laptop or PC USB ports must be 2 0 or greater to provide sufficient power to the unit AC Wall Adapter Input 100 to 240 10 VAC Output 5 VDC 2A max Operating Temperature 40 to 85 C 40 to 185 F DC configuration 10 to 50 C 14 to 122 F with AC wall adapter Storage Temperature 55 to 125 C 67 to 257 F Humidity 5 to 95 non condensing 0 to 10000 ft altitude Dimensions 2...

Страница 60: ...an use a GUI CPE Customer Premises Equipment end point of a leased fiber DC Direct Current DDMI Digital Diagnostic Monitor Interface a defined serial interface and data format typically used to access SFP internal information DHCP Dynamic Host Configuration Protocol used to automate configuration of computers that use TCP IP GUI Graphical User Interface software that provides a visual interface to...

Страница 61: ...m Both SNMP and RMON use standardized MIB formats that allow any SNMP and RMON tools to monitor any device defined by a MIB MSA Multi Source Agreement SFP standard an SFP must meet to be compatible in network devices NOC Network Operations and Control Center OAM Operations Administration and Maintenance OAM CFM IEEE 802 1ag Connectivity Fault Management PROM Programmable Read Only Memory SFP Small...

Страница 62: ...otiation or if using Force mode make sure speed and duplex match 3 IE MultiWay allows the end user to assign a VLAN tag to all management traffic SNMP and Telnet It is important to understand that IF using Telnet or iView2 to assign a VLAN tag to management traffic then as soon as this setting is saved the connectivity will be lost until the PC becomes a member of the VLAN which was assigned to ma...

Страница 63: ...ause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment The use of non shielded I O cables may not guaran...

Страница 64: ...o diagnose problems in an installation 2 Dust caps are installed at the factory to ensure factory clean optical devices These protective caps should not be removed until the moment of connecting the fiber cable to the device Should it be necessary to disconnect the fiber device reinstall the protective dust caps 3 Store spare caps in a dust free environment such as a sealed plastic bag or box so t...

Страница 65: ...s not available maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the electronic components or gold connectors 4 After removal always place the boards on a grounded static free surface ESD pad or in a proper ESD bag Do not slide the modules or standalone units over any surface WARNING Integrated circuits and ...

Страница 66: ...uld be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed informat...