background image

A)

 

Power LED

B)

 

Data LEDs

C)

 

Fiber Optic ports

D)

 

Serial TB

E)

 

Ground Lug

F)

 

DIP Switch

G)

 

Serial Mode Switch

H)

 

Power TB

Product Overview

Configuration DIP Switch

Fiber Optic Connections

Power & Ground Connection

Wiring Examples

1

4

2

3

Terminal

RS-485 2-Wire

RD422/485 4-Wire

A

---

TDA (-)

B

---

TDB (+)

C

DATA A (-)

RDA (-)

D

DATA B (+)

RDB (+)

E

Ground

Ground

Built-in Termination Resistor

5

Use the 120Ω Built-in Termination

ON

Use External or No Termination

OFF

Built-in Trasmit Bias Resistor

6

Use the External or No Bias Resistor

ON

Use the 1.2KΩ Transmit Bias Resistor

OFF

Built-in Receive Bias Resistor

7

Use the External or No Bias Resistor

ON

Use the 1.2KΩ Receive Bias Resistor

OFF

Fiber Optic Mode

8

Multi-drop Ring

ON

Point-to-point

OFF

1

2

3

4

RS-485 2-Wire 

Half Duplex

ON

ON

ON

ON

RS-485 4-Wire 

Full Duplex

ON

OFF

OFF

OFF

RS-422 Full 

Duplex

OFF

OFF

OFF

OFF

Terminal

Signal

Direction

A

RD

Output

B

---

---

C

TD

Input

D

---

---

E

Ground

---

For an explanation of RS-485 termination requirements, 

more documentation can be found at advantech-bb.com

+

2-Wire RS-485

RS-422/ 4-Wire RS-485

RS-232

Point-to-Point

Positions 5, 6, 7 are used for termination and biasing. Position 8 is 

used for fiber optic point-to-point or multi-drop ring.

Position 1 = ON for RS-485, OFF for RS-422. Positions 5, 6, 7 

are used for termination and biasing. Position 8 is used for fiber 

optic point-to-point or multi-drop ring

DIP Switch positions 1 through 

7 have no effect in RS-232 

mode. Set position 8 to OFF 

for fiber optic point-to-point or 

multi-drop ring.

Set DIP Switch position 8 to OFF on both converters. Connect 

Fiber Optic TD to Fiber Optic RD and vice versa.

E = Ground

Note: Your FOSTCDRi-PH-x converter can only connect to 

another FOSTCDRi-PH-x converter model at the other end of 

the fiber optic cable.

+