manualshive.com logo in svg
background image

Operation manual

Technical changes reserved

Infrared-thermometer IR 8895

0141 0316-190   30.11.2021

B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen 
Fon +49 771 83160 | Fax +49 771 8316-50 | [email protected] | bb-sensors.com

1 / 12

Содержание IR 8895

Страница 1: ...nical changes reserved Infrared thermometer IR 8895 0141 0316 190 30 11 2021 B B Thermo Technik GmbH Heinrich Hertz Straße 4 D 78166 Donaueschingen Fon 49 771 83160 Fax 49 771 8316 50 info bb sensors com bb sensors com 1 12 ...

Страница 2: ... 5 Setting up and operation 5 5 1 Control elements 5 5 2 Inserting batteries 6 5 3 Laser beam activation de activation 6 5 4 Temperature measurement 7 5 5 Changeover from C to F 7 5 6 Background illumination 8 5 7 Emission setting 8 6 Maintenance and cleaning 8 6 1 Cleaning 8 6 2 Replacing batteries 9 6 3 Disposal of used batteries 9 6 4 Scrapping and disposal 9 7 Technical data 10 8 Guarantee 10 ...

Страница 3: ...nable you to carry out exact temperature measurements even for highly demanding industrial applications Of course the instrument also complies with the current safety and environmental protection regulations and is conforming to RoHS This instruction manual made available to you shall help in adjustment and operation of the instrument The information is important to achieve optimum results and als...

Страница 4: ...ation of the device the safety instructions warnings and instructions provided in chapter on Application purpose shall be necessarily followed 2 1 General safety instructions The guarantee claim becomes void in case of damages caused due to non compliance to the instructions We take no liability for the consequential damages which result from such negligence This appliance is with CE conformance a...

Страница 5: ...t can stabilise itself to the new environment temperature Do not expose the equipment to high temperatures for a long time Avoid dusty and humid environment conditions After usage store the device in the storage bag to avoid contamination of the lens Consider technical facts of the measuring procedure to obtain exact results of measurement particularly the relationship of measuring spot size with ...

Страница 6: ... the instrument for the first time insert two new 1 5 V Batteries type Mignon AA Instructions on inserting batteries have been described in detail in the section Maintenance and cleaning 5 3 Laser beam activation de activation For a confidence of having done an exact measurement the infrared thermometer 8895 is provided with a red point laser This laser beam approximately shows the centre of the m...

Страница 7: ...he hottest point on the object to be measured the infrared thermometer 8895 can be pointed towards any point lying outside the measuring range and then with the trigger in pressed condition the desired range is to be scanned with zigzag movements till the hottest point is located Make sure that the measured object is not smaller than the measuring spot size for a given distance 5 5 Changeover from...

Страница 8: ...t finish paint or black adhesive film The device can not measure through transparent surfaces like for example glass or transparent film Instead the surface temperature of the glass or the transparent film gets measured For entering the respective emission factor the device is to be first activated by pressing the trigger Now press the Mode Save key C The emission symbol 6 begins to blink Then ent...

Страница 9: ...not been used for long because even leak proof batteries can cause corrosion Chemicals which can da mage the device or cause health hazards can leak through the batteries 6 3 Disposal of used batteries The disposal of batteries together with house garbage is not allowed Batteries containing harmful materials are marked with the symbol as shown on left which refer to the prohibition of dispoal with...

Страница 10: ...aged or removed Apart from the guarantee service if any essential repairs are required to be carried out the service is free However further services and also postage and packing expenses are chargeable Compensation demands on the basis of claim for liability or damages during the guarantee period are excluded and these are in general not legally covered 9 Repair and calibration services During th...

Страница 11: ...tainless steel assorted 0 2 0 6 10 2 Brass Material Emission value Brass polished 0 1 Brass raw surface 0 2 Brass oxidised 0 6 10 3 Aluminium Material Emission value Aluminium polished 0 1 Aluminium severely oxidised 0 25 Aluminium oxide at 260 C 0 6 Aluminium oxide at 800 C 0 3 Aluminium alloy assorted 0 1 0 25 10 4 Copper Material Emission value Copper polished 0 05 Copper oxidised 0 8 Copper gl...

Страница 12: ...d 0 55 Zirconium silicate up to 500 C 0 85 Zirconium silicate at 850 C 0 6 Quartz raw 0 9 Coal Graphite 0 75 Material Emission value Coal Carbon 0 95 Timber assorted 0 8 0 9 Enamel all colours 0 9 Oil paint all colours 0 95 Lacquers 0 9 Black colour matt finish 0 95 0 98 Aluminium paint 0 5 Water 0 98 Rubber finished 0 9 Rubber raw 0 98 Plastic different solids 0 8 0 95 Plastic sheets 0 05 mm thic...

Отзывы: