B-52 US-5000 Скачать руководство пользователя страница 5

B-52 US Series Professional Power Amplifiers  - Instruction Manual

THE BEAUTY OF POWER

US SERIES AMPLIFIERS

1. REAd INSTRuCTIONS

 – All the safety and 

operating instructions should be read before this 

product is operated.

2. RETAIN INSTRuCTIONS

 – The safety and 

operating instructions should be retained for future 

reference.

3. HEEd WARNINgS

 – All warnings on the  

amplifier and in the operating instructions should 

be adhered to.

4. FOLLOW INSTRuCTIONS

 – All operating and 

use instructions should be followed.

5. WATER ANd MOISTuRE

 – The amplifier should 

not be used near water - for example, a bathtub, 

washbowl, kitchen sink, laundry tub, wet basement, or 

near a swimming pool, and the like.

6. CARTS ANd STANdS

 – The amplifier should 

be moved with a sturdy cart. An amplifier and cart 

combination should be moved 

with care. Quick stops, excessive 

force, and uneven surfaces may 

cause the amplifier and cart 

combination to overturn. 

 

7. INSTALLATION

 – Install in accordance with the 

manufacturer’s instructions and local codes.

8. HEAT

 – The amplifier should be situated away  

from heat sources such as radiators, heat registers, 

stoves, or other appliances that produce heat.

9. POWER SOuRCES

 – This product should be 

operated only from the type of power source indicated 

on the rating label. If you are not sure of the type 

of power supply to your home, consult your product 

dealer or local power company.

10. gROuNdINg OR POLARIzATION

 – This 

product may be equipped with a polarized alternation-

current line plug (a plug having one blade wider than 

the other). This plug will fit into the power outlet only 

one way. This is a safety feature. If you are unable to 

insert the plug fully into the outlet, try reversing the 

plug. If the plug should still fail to fit, contact your 

electrician to replace your obsolete outlet. Do not 

defeat the safety purpose of the polarized plug.

11. POWER CORd PROTECTION

 – Power-supply 

cords should be routed so that they are not likely to be 

walked on or pinched by items placed upon or against 

them, paying particular attention to the cord in cor-

respondence of plugs, convenience receptacles, and the 

point where they exit from the amplifier.

12. CLEANINg

 – The amplifier should be cleaned 

only as recommended by the manufacturer. Clean by 

wiping with a cloth slightly damp with water. Avoid 

getting water inside the amplifier.

13. NON-uSE PERIOdS

 – The power cord of the 

amplifier should be unplugged from the outlet when 

left unused for a long period of time.

14. OBjECT ANd LIquId ENTRY

 – Care should 

be taken so that objects do not fall and liquids are not 

spilled into the amplifier through openings.

15. dAMAgE REquIRINg SERvICE

 – The  

amplifier should be serviced by qualified service 

personnel when:

 

A.

 The power-supply cord or the plug has been  

  damaged; or

 

B.

 Objects have fallen, or liquid has been spilled  

  into the amplifier; or

 

C.

 The amplifier has been exposed to rain; or 

 

d.

 The amplifier does not appear to operate  

  normally or exhibits a marked change in 

  performance; or

 

E.

 The amplifier has been dropped, or the chassis  

 damaged.

16. SERvICINg

 – The user should not attempt any 

service to the amplifier beyond that described in the 

operating instructions. All other servicing should be 

referred to qualified service personnel.

17. vENTILATION

 – Slots and openings in the 

amplifier are provided for ventilation and to ensure 

reliable operation of the product and to protect it from 

overheating, and these openings must not be blocked 

or covered. The openings should never be blocked 

by placing the product on a bed, sofa, rug, or other 

similar surface. This product should not be placed in a 

built-in installation such as a bookcase or rack unless 

proper ventilation as per the manufacturer’s instruc-

tions have been adhered to.

18. gROuNdINg

 – Always maintain reliable 

grounding of the rack and all equipment installed in 

the rack.

19. POWER

 – The power switch in your amplifier is 

not an all-pole AC switch. You must physically discon-

nect AC power cord from either amplifier or AC outlet 

to fully disconnect it from AC mains. Make sure you 

have access to the power cord if you need to disconnect 

it in case of emergency.

20. LIgHTNINg

 – For added protection for this 

product during a lightning storm, or when it is left 

unattended and unused for long periods of time unplug 

it from the wall outlet. This will prevent damage to the 

product due to lightning and power-line surges.

21. REPLACEMENT PARTS

 – When replacement 

parts are required, be sure the service technician has 

used replacement parts specified by the manufacturer 

or have the same characteristics as the original part. 

Unauthorized substitutions may result in fire, electric 

shock, or other hazards.

22. SAFETY CHECk

 – Upon completion of any 

service or repairs to this product, ask the service 

technician to perform safety checks to determine that 

the product is in proper operating condition.

IMPORTANT SAFETY PRECAuTIONS

CAUTION:

 To reduce the risk of electric shock, do not 

remove any cover. No user-serviceable parts inside. Refer 

servicing to qualified service personnel only.

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use to the 

presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient  

magnitude to constitute a risk of electric shock.

The exclamation point within the equilateral triangle is intended to alert the user to the presence of important 

operation and maintenance (servicing) instructions in the literature accompanying this appliance.

To prevent electric shock, do not use a polarized plug with an extension cord, receptacle or other outlet unless the blades 

can be fully inserted to prevent blade exposure.

CAUTION

5

Содержание US-5000

Страница 1: ...FIERS OWNERS MANUAL POWER PROTECT CLIP 10dB 20dB SIGNAL PROTECT CLIP 10dB 20dB SIGNAL BRIDGE PARALLEL CHANNEL 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 15 17 19 22 29 54 CHANNEL 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 15 17 19 22 29 54 POWER AMPLIFIER US 5000 US SERIES PROFESSIONAL POWER AMPLIFIERS US 5000 US 6000 ...

Страница 2: ...S Introduction 3 Warnings and Safety Instructions 4 5 Features 5 Power Ratings at a Glance 6 US Series Features 7 Front Panel Controls 8 9 Rear Panel Controls 10 13 Protection 13 15 Setup 15 16 Connections 17 18 Wiring 19 Cleaning the air filters 20 Specifications 21 Warranty 22 Notes 23 Contact Information 24 2 ...

Страница 3: ...tive that you read and understand all of the warnings in this manual regarding proper usage service and safety Failing to comply with any of these safety and operation warnings may void your warranty For more information about your US Series Amplifier log on to http www B 52Pro com or call our customer service support hotline toll free at 800 344 4384 or 1 323 277 4100 Thank you again for choosing...

Страница 4: ...ves or other devices that may produce heat 10 Do not defeat the safety purpose of the polarization or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit your outlet consult an electrician for replacement of t...

Страница 5: ... damaged or B Objects have fallen or liquid has been spilled into the amplifier or C The amplifier has been exposed to rain or D The amplifier does not appear to operate normally or exhibits a marked change in performance or E The amplifier has been dropped or the chassis damaged 16 Servicing The user should not attempt any service to the amplifier beyond that described in the operating instructio...

Страница 6: ...ERS POWER RATINGS AT A GLANCE US 5000 US 6000 Rated Output Power Stereo Both ChannelS Driven 8 Ohms 900 watts 1150 watts 4 Ohms 1500 watts 1900 watts 2 Ohms 2150 watts 2750 watts Rated Output Power Bridged Mono 8 Ohms 3000 watts 3800 watts 4 Ohms 4300 watts 5500 watts Both channels driven 1kHz 1 THD 6 ...

Страница 7: ...for stability and increased longevity High current toroidal transformers for increased 2 ohm power output 21 position gain control knobs for consistent settings Selectable STEREO PARALLEL MONO and BRIDGED MONO modes for flexibility Front panel LED display POWER BRIDGE and PARALLEL LEDs and SIGNAL 20dB 10dB 0dB CLIP and PROTECT LEDs for each channel Protection Short circuit output current limiting ...

Страница 8: ...Channel 1 and channel 2 LEVEL controls Use these 21 position detented controls to adjust the output levels of Channel 1 and Channel 2 When the LEVEL controls are set fully counter clockwise the signal is attenuated by more than 80dB marked When the LEVEL controls are set fully clockwise the signal is amplified with maximum gain When the LEVEL is set fully clockwise the amplifier produces its rated...

Страница 9: ...s indicates your amplifier is going through a transition process and the outputs are muted WARNING If the PROTECT LEDs illuminate constantly and don t turn OFF even when the speakers are physically disconnected from the amplifier s outputs this indicates a fault Immediately turn the amplifier OFF disconnect the power cord from the AC outlet and refer the amplifier to service personnel Authorized B...

Страница 10: ...A stereo signal should be connected to both the Channel 1 and Channel 2 input jacks for 2 channel stereo operation NOTE Unbalanced two conductor 1 4 plugs can also be inserted into these input Combo connectors But using unbalanced connectors may increase noise and hum See more information about balanced and unbalanced connections in the CONNECTIONS section later in this manual NOTE For BRIDGED MON...

Страница 11: ...ce the amount of distortion and stress on your speakers and amplifier It is recommended to keep these switches in the ON position as this will result in better sound and increase the life of your loudspeakers 6 BRIDGE STEREO PARALLEL switch Use this switch to change the amplifier s operating mode to STEREO BRIDGED MONO or PARALLEL MONO Set this switch to the STEREO position for normal stereo or 2 ...

Страница 12: ...d to the Channel 2 red post as indicated on the rear panel just below the binding posts WARNING NEVER CONNECT speakers with an impedance lower than the rated minimum impedance of the amplifier The lowest impedance in STEREO and PARALLEL modes is 2 Ohms for each channel The lowest impedance in BRIDGED mode is 4 Ohms NEVER CONNECT 2 Ohms rated loudspeaker s or a combination of speakers to the amplif...

Страница 13: ...hermal protection circuitry if the air access is not blocked and the air filters are clean 2 Ohms speaker loads per channel 4 Ohms in BRIDGE mode can cause the thermal protection circuitry to activate occasionally If this occurs decrease the signal level and consider reconnecting the speaker connections to reduce the load on the amplifier for example do not connect too many speakers in parallel to...

Страница 14: ...signals If this occurs the load will disconnect Check and cor rect the short wire condition DC Voltage Protection If an amplifier chan nel detects a DC voltage at the loudspeaker output the protection circuitry will trigger and the amplifier will go into protection mode In normal conditions there should not be a significant DC signal on the am plifier outputs DC on the outputs indicates a serious ...

Страница 15: ...sing it to clip A clipped waveform exhibits severe distor tions making it sound harsh The clip limiter detects this condition and reduces the gain to minimize the amount of overdrive To preserve as much of the program dynamics as pos sible the limiter reduces the average program level until the peaks barely clip Each chan nel has its own clip limiter and you can switch it ON or OFF The clip limite...

Страница 16: ... and the other channel pulls the signal equally doubling the voltage When the voltage is doubled the power is quadrupled if the same impedance load is used In a BRIDGE mode the signal must be applied to Channel 1 s input only and Channel 1 s gain control is used to adjust the signal level The gain control of Channel 2 is not used and input 2 is inactive in BRIDGE mode NOTE Minimum load impedance i...

Страница 17: ...tion Manual THE BEAUTY OF POWER US SERIES AMPLIFIERS CONNECTING YOUR SPEAKERS Stereo Mode Parallel Mode Bridged Mono A or B or _ _ B B _ _ _ A A A 5 Way Output Binding Posts A or 5 Way Output Binding Posts A Bridged Mono 5 Way Output Binding Posts 17 or ...

Страница 18: ...l Mode Bridged Mono A A or or B or _ _ B B _ _ A A SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 _ _ B B _ _ A A SPK to PIN 2 SPK to PIN 2 SPK to PIN 2 SPK to PIN 2 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 A A or _ Bridged Mono SPK to PIN 1 SPK to PIN 2 18 ...

Страница 19: ...n use either binding posts or Speakon connectors NOTE Use speaker wires with the lowest gauge available The thicker the speaker wires are the less output signal you will lose You have chosen US amplifiers that supply very high power to your loudspeakers and you don t want to sacrifice your system s performance by using inadequate speaker cables 19 UNBALANCED 1 4 CONNECTOR BALANCED 1 4 CONNECTOR SP...

Страница 20: ...o keep the US 5000 and US 6000 air filters clean and maintained to ensure the amplifiers operate at maximum efficiency 1 To remove the air filters simply slide them out using your finger 2 Open the filter covers as per below and clean the filter using a damp cloth 3 Reassemble the filter covers and return them to the slots on either side of the amplifier ...

Страница 21: ... DC offset RF protection AC soft start with inrush current limit turn on off muting Connectors Input Combo female XLR 1 4 phone jack Link Male XLR Output Both 5 way biding post and SpeakonTM Controls Front Power on off switch volume controls for each channel Rear Mode switch stereo parallel bridge HPF 30Hz 50Hz Off Limiter on off LED STRIPS on dim off Indicator Power parallel bridge Each channel S...

Страница 22: ... product even if B 52 or a B 52 dealer has been advised of the possibility of such damages or any other claim by any other party Some States do not allow the exclusion or limitation of consequential damages so the above limitation and exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that may vary from State to State PURCHASING FROM UNA...

Страница 23: ...B 52 US Series Professional Power Amplifiers Instruction Manual THE BEAUTY OF POWER US SERIES AMPLIFIERS 23 NOTES ...

Страница 24: ... 323 277 4108 Toll Free 800 344 4384 B 52 Professional is dedicated to product excellence and therefore continuously attempts to improve each and every model we manufacture This ongoing process includes refinements in design materials and workmanship which may result in products which differ than those described in our literature All features specifications prices and terms are subject to change w...

Отзывы: