Simply plug in the desired module board and turn on the power switch. 
Features included in the IQS227-228BEV02: 

  Modular  design:  Connect  one  of  the  supplied  plug-in  modules  into  the  main  board,  to 

evaluate and compare proximity and touch performance. 

  Reference designs for IQS227B and IQS228B with user proximity and touch detection. 

  Used in Data Streaming Mode: EV-Kit requires Micro-USB cable with Azoteq CT210A. 

The  EV-Kit  main  board  can  also  draw  power  from  a  USB  source  by  means  of  the  USB  Type-C 
connector provided on the main board (optional). 
 

2.1  Overview of module boards 

Table 1 gives a summary 

of the settings burned onto the IC’s. The Green, Blue and Black refer to 

the  different  coloured  module  boards  and  the  overlay  refers  to  the  thickness  of  the  removable 
Perspex  layers.  A  3mm  overlay  is  achievable  by  stacking  three  1mm  overlays  on  top  of  each 
other. The Target value is when the IC performs an Antenna Tuning Implementation (ATI) routine 
and adjusts the Compensation (Comp) and Sensitivity (Sense) multipliers for the Counts value to 
reach  the  Target  value.  The  Touch  Threshold  (TTH)  sets  the  point  where  a  Touch  event  is 
triggered.  This  is  calculated  as  a fraction  of the current  LTA  value.  For  simplicity,  an  example  of 
this calculation will be given.  
 
Example: 
With  a  TTH  set  to  48  and  a  Long  Term  Average  (LTA)  of  512,  the  equivalent 

ΔCounts  value  is 

calculated as follow: 
 

∆𝐶𝑜𝑢𝑛𝑡𝑠 = 𝐿𝑇𝐴 ×

𝑇𝑇𝐻

256

= 512 ×

48

256

= 96

 

 
This  means  that  when  the  Counts  value  is 

ΔCounts  below  the  LTA,  the  Touch  event  will  be 

triggered. 
 

Table 1: Settings for the module boards 

IC 

Module 

Board 

Overlay 

Target 

TTH 

Multiplier 

Compensation 

Multiplier 

Sensitivity 

IQS227B 

Green 

1mm 

512 

48 

13 

 

Blue 

2mm 

1024 

48 

14 

 

Black 

3mm 

1024 

24 

Full ATI 

 

 

 

 

 

 

 

IQS228B

 

Green 

1mm 

1024 

72 

13 

 

Blue 

2mm 

1200 

72 

 

Black 

3mm 

1200 

24 

Full ATI 

 

3  Standalone Operation 

3.1  Powering on the device 

In order to power the device, make sure the main board is set up as follow: 

  Connect the IQS227B (green board) plug-in module board. 

  Put 1 overlay on the base board. 

  Move the slide switch to the ON position. 

Always switch OFF the device before making alterations to the main board. This is needed for the 
Integrated Circuit (IC) to adjust to the main board setup. 
 
There are 3 alterations available: 

  The plug-in module board can be exchanged for another board in the EV-Kit. 

  The overlays can be added or removed as needed. 

  The jumper can be shifted to connect the adjacent pads to the button. 

 

Содержание IQS227BEV02

Страница 1: ...e Designs 9 1 Introduction This user guide describes the operation of the IQS227 228BEV02 Evaluation Kit The EV Kit consists of ten parts the main board device six separate plug in module boards and t...

Страница 2: ...the Counts value to reach the Target value The Touch Threshold TTH sets the point where a Touch event is triggered This is calculated as a fraction of the current LTA value For simplicity an example...

Страница 3: ...t operation and false Prox events will be triggered when touching the ground pour areas on the board Figure 3 1 Jumper placement When the jumper is connected on the PROX and GND pins the 2 pads on eac...

Страница 4: ...gn capacitance sensor software and tools Figure 4 1 Setup for data streaming Setup the base board connection with a computer by doing the following Connect the CT210A to a computer via a micro USB cab...

Страница 5: ...ck to Standalone mode If you click the Start button you will receive a Timeout during operation error in the Message box When everything is setup correctly and working in the data streaming mode the G...

Страница 6: ...ay to get out of this stuck condition is to wait for the Time Out timer to complete and re ATI the IC The default Time Out time is 18s An important consideration is the Production Spread Guideline bar...

Страница 7: ...should look like Note that the Counts and LTA bars have turned red to indicate a Touch event and the Filter Halt is still Active Figure 4 5 IQS227B Touch Event The various IQS227B module boards can n...

Страница 8: ...needed as during long Touch events the environment can change and the device compensates for these slow varying changes The device exits the Touch event when the Counts value rise a certain amount ab...

Страница 9: ...on Kit User Guide Page 9 of 10 All Rights Reserved Revision 1 0 November 2022 6 Reference Designs Figure 6 1 and Figure 6 2 shows reference designs for the main board and the module boards Figure 6 1...

Страница 10: ...and information including but not limited to all implied warranties and conditions of merchantability fitness for a particular purpose title and non infringement of any third party intellectual prope...

Отзывы: