Technical Principles
1ª review – UK 12 – 2020
17
a pre-selection is pressed, only the product labels affected by that pre-
selection are illuminated, the rest is turned off.
On the electronic pushbutton card, the display is connected, which is of the
alphanumeric type with two lines of 16 characters each.
The pushbutton card is tied with 4 plastic nuts and protected by a plastic
panel. The label holders are attached to the card by pressure. To access the
card, the cup container must be removed.
2.2. Hydraulic circuit
Conecction to water network
JI1. Water deposit
J2. Flowmeter
J3. Pressure pump
J4. Overpressure pump
J5. Non return
J6. Boiler
J7. Electrovalves
J8. Water inlet valve
Autonomy mode
I1. Water deposit
I2. Flowmeter
I3. Pressure pump
I4. Overpressure pump
I5. Non return
I6. Boiler
I7. Electrovalves
I8. Autonomy pump
I9. Plastic jerry
Содержание VITRO X-1
Страница 1: ...Technical information VITRO X1 ...
Страница 3: ...Technical Principles 1ª review UK 12 2020 3 ...
Страница 6: ...Technical Principles 1ª review UK 12 2020 6 2 DESCRIPTION OF COMPONENTS 2 1 MAIN COMPONENTS ...
Страница 27: ......