background image

  

Protocol - Modular AC-DSP 

V1_version Feb-2011

 

11 

 

 

3.4

 

Validator AC-DSP in Credit mode. 

The  operation  of  the  validator  in  credit  mode  gives  a  credit  signal  to  achieve  the 

programmed price. This signal will be a configurable in the "1" time and the "0" time. 

The pinout of the connector J1 in this operating mode is as follows: 

 

Connector J1 Output module 

Pins 

Function 

Notes 

Pin 1  

GND 

 

Pin 2 

12-24 Vdc 

Minimum: + 10 Vdc; Maximum: +27 Vdc 

Pin 6 

Input 

Inhibition of coins/service request 

Pins 3, 4, 

5,7,8,9 and 10 

Output 

Outputs  available  for  Credit,  Counter,  Available 
credit 

Table 5. Pinout for Credit mode 

These validators offer two operating modes: 

 

Working with continuous pulses. 

When  the  programmed  price  is  reached  (or  exceeded),  the  validator  automatically 

and continuously gives credit pulses corresponding to the amount introduced. 

Input pin 6 serves as inhibition in the acceptance of coins. The range of inhibition is 

configurable. 

Example: 

Price: 

€ 1

  

Pulses for this price: 

5 pulses

  

The user introduces 

€ 2

  

The validator immediately provides 10 pulses to the corresponding pin. 

 

Working in Service Request Mode. 

When the programmed price is reached (or exceeded) the user needs to request the 

service  on  pin  6  to  obtain  a  service.  Once  this  happens,  the  corresponding  service 

credits will be supplied. 

Содержание A6-D2S

Страница 1: ...Protocol Modular AC DSP V1_version Feb 2011 1 Modular AC...

Страница 2: ...ERATION 6 3 1 Selecting the operating mode 6 3 2 Validator AC DSP in Parallel mode 7 3 3 Validator AC DSP in Timer mode 8 3 4 Validator AC DSP in Credit mode 11 4 MODIFIABLE OPERATING PARAMETERS 13 4...

Страница 3: ...3 Pinout in parallel mode 7 Table 4 Pinout Timer mode 8 Table 5 Pinout for Credit mode 11 Table 6 Modifiable parameters using switches 13 Table 7 Configurable Parameters 17 Index of Figures Figure 1...

Страница 4: ...iled information on this point consult paragraph 1 2 of the manual Technical Information In this manual the general term AC DSP will refer to any of the above validators For full information on the te...

Страница 5: ...or is through pins 1 GND and 2 Vdc for this connector The function of each of the pins will vary depending on the operating mode selected by the user See section 3 Operation for details 2 2 Connector...

Страница 6: ...wered through the J1 connector for communication between the Validator and the Azkoyen tools 3 OPERATION 3 1 Selecting the operating mode To select the desired operating mode use the dip switches on t...

Страница 7: ...odule Pins Function Notes Pin 1 GND Pin 2 12 24 Vdc Minimum 10 Vdc Maximum 27 Vdc Pin 3 Output 5 Open collector transistor NPN Pin 4 Output 6 Open collector transistor NPN Pin 5 Output 7 Open collecto...

Страница 8: ...Notes Pin 1 GND Pin 2 12 24 Vdc Minimum 10 Vdc Maximum 27 Vdc Pin 6 Input Inhibition coins request service Pins 3 4 5 7 8 9 and 10 Output Available for output of Operating time Counter Warning signal...

Страница 9: ...inimum of 50 milliseconds This pin has to go back to the inactive state during a minimum time of 50 milliseconds to make the sale of the next signal If the introduced amount was higher than the price...

Страница 10: ...dator will not work Once the user requests the service the validator will give a signal of 60 seconds to the corresponding pin A new service request is required to obtain the 60 remaining seconds In t...

Страница 11: ...r Available credit Table 5 Pinout for Credit mode These validators offer two operating modes Working with continuous pulses When the programmed price is reached or exceeded the validator automatically...

Страница 12: ...ds The user introduces 2 Until the user requests the service on 6 pin the validator will not work Once the user requests the service the validator will give 5 pulses to the corresponding pin A new ser...

Страница 13: ...Tables 1 0 1 Bonus 0 1 1 Table 6 Modifiable parameters using switches To programme the parameters with dipswitches follow the steps below 1 Place SW3 SW2 and SW1 dipswitches with the parameter settin...

Страница 14: ...oken 2 1 Place the dipswitches to be programmed for token 1 or token 2 2 Put dipswitch SW4 ON The electromagnet on the acceptance gate will make a short click 3 Introduce a minimum of 25 tokens that y...

Страница 15: ...ill make a short click 3 Place dipswitch SW4 in the OFF position The electromagnet on the acceptance gate will make a long click 4 2 Parameters that are configurable using Tools As already mentioned i...

Страница 16: ...ce request Continuous with Service request Price of service Time of service Pin of timer Available credit pin Counter activated YES NO Pin counter default pin 8 Time ON of counter Time OFF of counter...

Страница 17: ...a configurable parameter by the user it may be useful know factory default settings LOGIC LEVEL 0 From 0 volts to 0 7 volts LOGIC LEVEL 1 From 4 volts to 5 volts 5 AZKOYEN TOOLS 5 1 HEUS The HEUS use...

Страница 18: ...To know the details of the implementation and management of the HEUS consult the specific manual available on the Azkoyen website http sat azkoyen com 5 2 TL20 The TL20 is a hardware tool that is used...

Страница 19: ...ning of the validator as it simulates the behaviour of a machine There are numerous configuration switches as well as a Display to setup different working modes in the validator Figure 7 IS21 A To kno...

Отзывы: