Azbil RA1B Скачать руководство пользователя страница 17

9

Chapter 3  Operation

This chapter describes how to start and stop this device and how to adjust the pressure.
If the user’s manual for the product on the secondary side provides instructions on how to start and stop operation 
and how to adjust pressure, follow them instead of the instructions in this document.

 

„

How to Start Operation

(1)  Change the pressure to the lowest setting before supplying air to this device. (See 

„

 

How to Adjust the Pressure

.)

(2)  Check the state of connections on the secondary side of this device, and make sure 

that there is no chance of devices being damaged or malfunctioning due to a release 
of unadjusted air pressure.

(3)  Supply air to this device, and adjust the pressure by following the prescribed 

procedure. (See 

„

 

How to Adjust the Pressure

.)

(4)  Check that the product on the secondary side functions normally. If so, the procedure 

is completed.

 

„

How to Stop Operation

(1)  Check the operation of the device on the secondary side, and make sure that there is 

no chance of it being damaged or malfunctioning due to fluctuations in air pressure 
output before stopping this device. Close the shutoff valve, if any, on the secondary-
side pipe.

(2)  Change the pressure of this device to the lowest setting. (See 

„

 

How to Adjust the 

Pressure

.)

(3)  Stop supplying air to the primary side of this device.
(4)  After tightening the slotted screw or pressure adjustment knob slightly, change 

the pressure to the lowest setting again and then release residual pressure from the 
primary side.

(5)  If the residual pressure cannot be released in one operation, repeat operation (4) 

several times.

(6)  Check for any residual pressure and then confirm that there is nothing abnormal with 

this device or the air piping. This completes the procedure.

 Note

•  If the piping is laid out in such a way that residual pressure on the primary side is 

released when the air supply is stopped, steps (4) and (5) can be omitted.

 

„

How to Adjust the Pressure

If this device is attached to a product that does not always expel air and the piping capacity 
of the secondary side is large, it will take some time for the air pressure to reach the 
specified pressure. Adjust the pressure after closing the pipe at a position immediately after 
the pressure regulator, or check the pressure after sufficient time has passed.
Before, after, or during pressure adjustment, check for air leakage from the seals and piping 
connection ports. If the pressure fluctuates drastically because of a sudden operation, this 
device may be damaged or malfunction, or air may leak.

Содержание RA1B

Страница 1: ...CM2 RA1B10 2001 Pressure Regulator with Air Filter Model RA1B User s Manual...

Страница 2: ...fications in this manual are subject to change without notice Considerable effort has been made to ensure that this manual is complete and accurate but if you should find an omission or error please c...

Страница 3: ...injury or property damage only In describing the product this manual uses the icons and conventions listed below Indicates that caution is required in handling The indicated action is prohibited Be s...

Страница 4: ...s a risk of falling Do not touch the device unnecessarily while it is operating Depending on the operating conditions the surface might be extremely hot or cold Since this product is heavy when handli...

Страница 5: ...del number and product number ready z Precautions for storage Observe the following precautions when storing the purchased device in an unused state Store the product at normal room temperature and hu...

Страница 6: ...ture and operating principles Chapter 2 Installation How to install this device and points to keep in mind during installation Chapter 3 Operation Procedures and important points for operating and sto...

Страница 7: ...1 Operating Principles 2 Chapter 2 Installation 3 Description of Parts 3 Instrumentation Air 5 Installation Procedure 6 Chapter 3 Operation 9 How to Start Operation 9 How to Stop Operation 9 How to Ad...

Страница 8: ......

Страница 9: ...nges in primary pressure or secondary side load resistance In addition it has a built in filter to remove solid foreign matter Structure 3 4 22 21 19 20 18 11 5 6 7 7 8 9 10 15 16 17 13 14 12 1 2 Blee...

Страница 10: ...ing plate Stainless steel 10 Main unit Aluminum alloy 23 Pressure adjustment knob PBT resin stainless steel 11 Pressure adjustment spring Spring steel 24 Flange nut M6 Stainless steel 12 Pressure adju...

Страница 11: ...igures below z Model RA1B 1 Fig 2 1 RA1B 1 Side view Pressure gauge connection port Rc1 8 Air pipe connection port OUT Air pipe connection port IN Fig 2 2 RA1B 1F Top view Pressure gauge connection po...

Страница 12: ...nstallation z Models RA1B 2 and RA1B 3 Fig 2 4 Side view Air pipe connection port OUT1 Air pipe connection port OUT2 Air pipe connection port IN Fig 2 5 Top view Bolt hole M6 2 with cover seals Fig 2...

Страница 13: ...terminal If measures cannot be taken on the main line due to installation of a control valve or for other reasons use a compressed air purifier oil mist removal equipment device that can be installed...

Страница 14: ...the pressure regulator body Note The M6 screw holes are covered with cover seals Remove them before use No M6 screws are included with this device Please obtain them separately For the dimensions of...

Страница 15: ...it and this device so as not to damage this device Not doing so may result in damage malfunction or air leakage If this device is damaged touching the damaged surface may cause an injury If the M4 sc...

Страница 16: ...n port Doing so may result in damage malfunction or air leakage Take steps to prevent a detached plug or part from falling Do not supply instrumentation air until all the air pipe connection ports are...

Страница 17: ...2 Change the pressure of this device to the lowest setting See How to Adjust the Pressure 3 Stop supplying air to the primary side of this device 4 After tightening the slotted screw or pressure adjus...

Страница 18: ...to drop or lose the cover screw when it is removed If the slotted screw is overtightened beyond the adjustable range it may fall into the pressure regulator making it impossible to adjust the pressur...

Страница 19: ...mes into contact with the M4 thread when opening or closing the flange nut the M4 thread may be damaged In addition coming into contact with damaged thread may result in injury If the pressure adjustm...

Страница 20: ......

Страница 21: ...to vibration or other reasons tighten it as follows z Required tool and tightening torque Tool monkey wrench or other appropriate tool Tightening torque 3 0 N m or less Handling Precautions The tighte...

Страница 22: ...ightening torque 2 0 2 N m Handling Precautions Do not bend or scratch the filter Do not use a filter that is damaged etc Doing so may result in damage air leakage or malfunction The filter may not fi...

Страница 23: ...opriately as industrial waste in accordance with local regulations To dispose of this device after disassembling it take appropriate action such as recycling each material by referring to chapter 1 St...

Страница 24: ...made of a cast aluminum alloy If there are any burrs they can cause injury If the resin knob cracks coming into contact with the cracked surface or fragments may result in injury If a screw head or n...

Страница 25: ...3 Model RA1B 3 primary pressure 1000 kPa Flow rate L min Flow rate L min Air consumption 0 5 L min normal max Material Filter 3 m PVA sponge or 3 m stainless steel option Case die cast aluminum Exter...

Страница 26: ...4 Paint Standard baked acrylic finish S Corrosion resistant baked urethane finish B 5 Environmental specifications temperature range Standard 30 to 80 C S Corrosion resistant 20 to 80 C diaphragm gas...

Страница 27: ...orporation DIMENSIONS RA1B 1F Unit mm Air pressure connection outlet Rc or NPT Pressure gauge connection port Rc 1 8 screw pitch With pressure gauge optional Air pressure connection inlet Rc or NPT In...

Страница 28: ...SS2 RA1B10 0100 RA1B 1P Unit mm Air pressure connection outlet Rc or NPT Pressure gauge connection port Rc 1 8 With pressure gauge optional 25 screw pitch Air pressure connection inlet Rc or NPT Inden...

Страница 29: ...zbil Corporation RA1B 2 3 Unit mm Air pressure output Rc or NPT screw pitch Air pressure inlet Rc or NPT With pressure gauge optional M6 nut 4 M4 mounting screw Drain plug Indentation for NPT pipe thr...

Страница 30: ...o your use 3 Measures to be taken to secure the required level of the reliability and safety of your Equipment in your use Although azbil is constantly making efforts to improve the quality and reliab...

Страница 31: ...argin of your machine or equipment you are required to renew any Azbil Corporation s products every 5 to 10 years unless otherwise specified in specifications or instruction manuals System products fi...

Страница 32: ...1 12 2 Kawana Fujisawa Kanagawa 251 8522 Japan URL https www azbil com 11 Specifications are subject to change without notice 1st edition May 2022 S...

Отзывы: