![Azbil MagneW Plus+ NNK140/941 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/azbil/magnew-plus-nnk140-941/magnew-plus-nnk140-941_user-manual_3042667029.webp)
Azbil Corporation
MagneW PLUS+ Electromagnetic Flowmeter Open channel Flowmeter Detector
23
A detector is used in combination with a Open channel type detector (Type NNK)
and a converter (Type MGG10C/14C). Its output signals are instantaneous flow rate
signals (4 to 20mA DC), totalized output (pulse) and contact output (open collector).
+ - + -
+ - + -
X Y
H N G
A B C
MGG10C/14C
Converter
Exciting current
Power
P+ / P-
I+ / I-
Input signal
Contact output
Contact input
Category D ground
Submersible detector
(Type NNK)
100V AC
or
Selected power
supply
Category D
ground
Pulse
A submersible electromagnetic flowmeter has
10m long cables as standard accessories.
Red
Green
White
Black Shield
4 to 20mA
(Pulse output)
(analog output)
Figure 12
Connection of converter and detector
X Y
A B C
MGG10C/14C
Converter
A B C X
Y
Category D ground
Detector
Cable connection box
(Model No NNZ102-X-X)
The cable can be extended to 100m.
(Model No. SMC11- HC)
Connected with standard 10mm long cable
Wiring diagram when a cable connection box is used
for connecting more than 10m long cables.
Red
Green
White
Black
Shield
Figure 13
Wiring to connection box
Содержание MagneW Plus+ NNK140/941
Страница 4: ......
Страница 6: ...List of Table Table 1 Tightening torque of detector 14...
Страница 8: ...Azbil Corporation 2 MagneW PLUS Electromagnetic Flowmeter Open channel Flowmeter Detector...
Страница 10: ...Azbil Corporation 4 MagneW PLUS Electromagnetic Flowmeter Open channel Flowmeter Detector...
Страница 22: ...Azbil Corporation 16 MagneW PLUS Electromagnetic Flowmeter Open channel Flowmeter Detector...
Страница 35: ......
Страница 38: ......
Страница 40: ......