Azbil ACTIVAL SCS13A Скачать руководство пользователя страница 7

AB-6464

7

 

z

Actuator

Item

Specification

Power supply

24 V AC ± 15 %, 50/60 Hz

Power consumption

Nominal 135 Ω feedback

potentiometer

7 VA

Nominal  135  Ω  resistance 

input

8 VA

4–20 mA DC input
2–10 V DC input

Actuator

For valve size DN15 to DN80 Standard torque type

Valve travel time

63 ± 5 s  (50 Hz) , 53 ± 5 s  (60Hz)

Control signals

Nominal 135 Ω feedback

potentiometer

Feedback potentiometer: total resistance = nominal 135 Ω

Max. applied voltage: 5 V DC

Nominal 135 Ω resistance 

input
4–20 mA DC input

Input impedance: 100 Ω

2–10 V DC input

Input impedance: 150 kΩ or more

2–10 V DC output 

signal for valve 

position

(applied for the 4–20 

mA DC input and 

2–10 V DC input)

Output voltage range

2 V DC  (fully closed)  to 10 V DC  (fully open)

Maximum load resistance

10 kΩ or more  (max. output current: 1 mA)

Valve position 

Indication

Indicator:  0  (fully closed)  to 100  (fully open)  

 

 

Can be seen from the forward, backward, or lower position. 

Wiring

Screwed on the terminal block  (M3.5) , tightening torque 0.8–1.0 N•m

Note: Open an appropriate knockout hole (dia. 22) located on both sides of the actuator at the worksite. 

Enclosure protection IEC IP54  (dust-proof, splash-proof)
Valve position for 

shipment

Fully open

Major materials

Case

Aluminum diecast

Top cover, terminal cover

Polycarbonate resin, color: gray  (equivalent to DIC-651)  

Yoke

Steel plate

Surface finishing

Case

None

Yoke

Electro-galvanizing  (bright chromate finish)

Содержание ACTIVAL SCS13A

Страница 1: ...mostat Model TY9800 4 20 mA DC input Provides proportional control in combination with a DDC controller e g Infilex GC Model WY5111 Model R35 R36 2 10 V DC input Provides proportional control in combi...

Страница 2: ...equency of use as basic parameters The recommended design life of this product is 10 years The recommended design life assumes that maintenance such as replacement of the limited life parts is carried...

Страница 3: ...125 CAUTION After installation make sure no fluid leaks from the valve pipe connections Improper piping may cause fluid leakage outside of the valve Do not put a load or weight on this product Doing s...

Страница 4: ...ers 1 Total resistance Nominal 1 k Operation range 0 fully closed to 100 fully open Max applied voltage 5 V DC Note It cannot be connected with Model M904E Valve flange adapter kit 4 Valve size Major...

Страница 5: ...on location Indoor use Note Salt air corrosive gas flammable gas and organic solvent must be avoided Outdoor use Note Salt air corrosive gas flammable gas and organic solvent must be avoided And use t...

Страница 6: ...mperature of fluid Chilled hot water 0 175 C Note When using the stainless steel valve with chilled water of 0 C or lower please contact Azbil Corporation 175 C steam 0 175 C 200 C steam 0 200 C Flow...

Страница 7: ...tion applied for the 4 20 mA DC input and 2 10 V DC input Output voltage range 2 V DC fully closed to 10 V DC fully open Maximum load resistance 10 k or more max output current 1 mA Valve position Ind...

Страница 8: ...maintenance 2 For setting the auxiliary switch make sure to allow a clearance of 300 mm or more Figuar 1 Dimensions mm Table 1 Dimension table mm Valve size L L1 H H1 D C t h N DN15 108 50 213 75 95 7...

Страница 9: ...For setting the auxiliary switch make sure to allow a clearance of 300 mm or more Figuar 2 Dimensions mm Table 2 Dimension table mm Valve size L L1 H H1 D C g t h N DN15 108 50 213 75 95 70 51 12 15 4...

Страница 10: ...AB 6464 10 Parts Indication Actuator Yoke Valve body Pointer Terminal cover Top cover Knockout hole Top lid Top cover Joint Stem Gland packing Seat ring Plug Figuar 3 Parts Indication...

Страница 11: ...ve install it on the pipe diverting sections for each piping group Do not install this product near a steam coil hot water coil etc High temperature radiant heat may cause failure of the actuator Avoi...

Страница 12: ...he factory CAUTION After installation make sure no fluid leaks from the valve pipe connections Improper piping may cause fluid leakage outside of the valve Do not put a load or weight on this product...

Страница 13: ...te A special sheet is inserted between the yoke and valve for heat insulation When you changed the mounting position be careful not to lose the sheet 4 Make sure that the groove on the tip of the valv...

Страница 14: ...y of the power supply and 2 10 V DC feedback signal and then correctly wire the product Incorrect wiring may result in PCB print circuit board burnout z z How to maintain IP54 dust proof splash proof...

Страница 15: ...terminals 4 to 7 Note Correctly connect the wires referring to Fig 9 to Fig 13 Terminals Connection Fig 14 to Fig 27 Wiring Examples and Advanced Wiring Examples 4 Mount the terminal cover and attach...

Страница 16: ...troller V Voltage between 4 and 6 Figuar 10 z z Nominal 135 resistance input Model VY512_J 4 5 6 7 To controller 24 V AC power Open Open R B W T2 T1 1 3 2 Figuar 11 z z 4 20 mA DC input Model VY513_J...

Страница 17: ...put Model VY513_ Model R35 Model R36 ACTIVAL 4 20 mA DC input Model VY513_ 4 5 6 7 T1 T2 1 2 1 3 2 Power transformer Model AT72 J1 100 200 V AC 1 The terminal 2 power terminal 5 4 20 mA DC input and t...

Страница 18: ...ce life the minimum opening position cannot be maintained Avoid instrumentation that may cause secondary dam age in case of abnormality Figuar 18 Using relay interlock ACTIVAL Nominal 135 resistance i...

Страница 19: ...duct will malfunction Input signals and power are shared Model R35TC0 Model R36TC0 ACTIVAL 4 20 mA DC input Model VY513_ Isolator 2 3 3 1 1 2 3 4 5 6 7 ACTIVAL 4 20 mA DC input Model VY513_ Isolator m...

Страница 20: ...ed 2 Terminals 2 5 and 7 are internally connected 3 Refer to notes under Power transformer is shared Figuar 24 Power is shared Model WY5117 Model WY5117 ACTIVAL 2 10 V DC input Model VY514_ Isolator 2...

Страница 21: ...ON Do not put a load or weight on this product Doing so may damage the product Before doing maintenance be sure to turn off the power to this product Failure to do so may result in electric shock or d...

Страница 22: ...rminals Check the wirings Leakage is observed when the valve is fully closed Pointer position when the valve is fully closed Fully close the valve Abnormal sound or vibration is observed Check that le...

Страница 23: ...AB 6464 23 This blank page was added for page layout purposes...

Страница 24: ...al and Electronic Equipment Directive RoHSD EMCD EN 61000 6 2 EN 55011 Class A Group 1 RoHSD EN 50581 ACTIVAL is a trademark of Azbil Corporation Infilex is a trademark of Azbil Corporation Specificat...

Отзывы: