background image

8

m/s

AVG

m/s

AVG

m/s

AVG

m/s

AVG

AVG

%

RH

AVG

%

RH

Fig.E

Fig.F

Timed average 

In normal mode, press       for 2 seconds
and it goes into multi-point average. 
Press it again to enter timed average 
mode.

 (See Fig.G, the upper display shows 

the duration time in 

second

, the maximum

time is 19999 seconds, and the lower is the 
measured reading)

AVG

AVG

- Press        to start recording, the upper
  display starts the counting clock. 
- Press        to stop and calculate the 
  timed average. It shows the duration
  seconds on the upper display and the
  average readings at the lower display
  with flashing”         “. (See Fig.H)

 

AVERAGE

This meter calculates multi-points
average and timed average of all 
parameters. 

Multi-points average 

In normal mode, press       for 2 seconds
to enter multi-point average mode.

(See 

Fig.E, the upper display shows the record 
number and the lower is the measured reading)

- Press        to record readings.
- Press       to see the multi-point average
  once all data is recorded. It shows the 
  average readings with flashing”         “. 
- Press        to view the average reading 
  of each parameter. 
  

 

AVG

AVG

- Press        to return to normal mode.

(See Fig.F, the upper display means total 
 20 recorded data; and the lower display is 
 the average reading of RH.) 

Содержание 89161

Страница 1: ...Operation Manual Model 8903 8904 8906 10cm Vane Wireless Air Flow Meter with Airflow cone Model 89161 89171 89191...

Страница 2: ...calculations automatically A hassle free way to take the value of air volume Features 1 INTRODUCTION Big LCD digital display Multi points and Timed average Metric Imperial units selectable Optional R...

Страница 3: ...RH Upper display air velocity RH CO2 value Depends on model duration time in average Lower display air volume temp WBT DP freezes the current reading MAXMIN maximum minimum reading Depends on model v...

Страница 4: ...enter data settings Switch for upper display Long press to enter average mode In average mode press to select option of average mode press again to return to normal mode In setup mode press to select...

Страница 5: ...preset auto sleep in 20 minutes of inactivity To disable this function hold down and for 2 seconds to turn on the meter while it is off It shows n on the LCD see Fig A and goes into normal mode or 30...

Страница 6: ...me it is necessary to get the outlet dimensions Go to Setup mode and input the AREA value first before taking measurement See page 9 P2 0 CMM After AREA setting is completed press to switch the displa...

Страница 7: ...also possible to display with RH offset Go to Setup mode see page 9 P3 0 and input offset value then the displayed readings will be the measured data with offset To measure air volume with use of an a...

Страница 8: ...gs of other parameters 7 CO2 89191 only Model 89191 features additional CO2 measurement for HVAC application The NDIR CO2 sensor is built in the rear side of the meter Press to switch to CO2 display a...

Страница 9: ...upper display and the average readings at the lower display with flashing See Fig H AVERAGE This meter calculates multi points average and timed average of all parameters Multi points average In norm...

Страница 10: ...Imperial unit The units include air velocity m s fpm temp C F air volume cmm cfm and 2 2 area size cm inch After finishing the setting press to return to P1 0 O O C cm 2 m s CMM O O C cm 2 CMM Fig J F...

Страница 11: ...s to enter pressure input It shows default 1013 hpa on the display with blinking value at the upper Fig P Press to increase the pressure value and to decrease it Once finished press again to return to...

Страница 12: ...s 400ppm 400ppm calibration is suggested to be done in outdoor fresh air that is well ventilated and in sunny weather 400ppm calibration Note When the accuracy becomes a concern after a long time use...

Страница 13: ...re the batteries are with full voltage during the calibration to prevent from interruption and fail in the calibration 1 While the meter is turned off hold down and simultaneously to enter CO2 calibra...

Страница 14: ...tton next to the parameter to remove the one you don t want to see at the main page and press again to add it back Main Page Press to return to the main page and view the current measuring values of d...

Страница 15: ...page you will see the detail of current measurements of the specific meter Press Time Avg to enter the Timed average mode Press Start to start recording the upper right corner display the time durati...

Страница 16: ...ect the file and you will see the CSV option appear You can select multiple files to send them in CSV format for further analyze Edit File Name Select the file and you will see the Rename option appea...

Страница 17: ...the number between 0 12 for RH off set setting Press ok to confirm Pressure input 89191 only Press Absolute pressure to start Enter number between 700 1990 for pressure compensation Press ok to confi...

Страница 18: ...n 1 Air Temp E02 Temp is under low range limit Put the meter in room temp for 30 minutes If E02 still shows send to the dealer for repair E03 Temp is over high range limit Put the meter in room temp f...

Страница 19: ...velocity error Try recalibration or send for repair if it still can t work 6 CO2 E03 Temp is over high range limit Put the meter in room temp for 10 minutes and if E03 still shows recalibrate it or se...

Страница 20: ...trolled environment This equipment should be installed and operated with a minimum distance of 0 5 centimeters between the radiator and your body This transmitter must not be co located or operating i...

Страница 21: ...o 0 1m s 0 1 0 9999 9 or 1 10000 99999 0 1 C F 0 1 RH Relative Humidity DP Dew point temp WBT Wet bulb temp 0 1 99 9 RH o 5 0 59 9 C o 20 0 59 9 C Relative Humidity o 3 RH at 25 C 10 90 RH 5 RH other...

Страница 22: ...oes not cover battery misuse abuse alteration tampering neglect improper maintenance or damage resulting from leaking batteries WARRANTY Authorization must be obtained from the supplier before returni...

Страница 23: ...ger Datalogging printer Gas Leak Detector CO meter CO2 meter Hygrometer Psychrometer RTD probe Thermometer K J T R S E type Thermometer Heat Index Meter WBGT Meter Infrared Thermometer Manometer Tacho...

Отзывы: