Condensation may form on your LEVANTE in the following cases:

 

• Immediately after turning on the heating

 

• In places with fog or a high level of humidity

 

• When the luminaire is suddenly moved from a cold to a warm 

environment, or vice versa.

In such cases, you must wait until the luminaire readjusts to the ambient 
temperature of the room where it will be installed for operation.

Do not shake the LEVANTE while installing or handling.

Do not pull the LEVANTE by one of its cables to move it. Lift the luminaire 
by its handles.

Choosing the appropriate place to install the LEVANTE is essential. The 
following points should be observed:

 

• Do not expose it to a heat source.

 

• Do not install it near flammable materials.

 

• Be sure that dust or miscellaneous debris cannot clump around the 

body of the luminaire as this may interfere with its optimal cooling and 
proper operation.

 

• The LEVANTE must be installed out of reach of the public and all 

persons not authorized to operate the luminaire.

We recommend a minimum distance of 5 m between the outside surface 
of the light and the illuminated object.

Due to the nature of its cooling principle, you should never prevent air 
from circulating around the body of the luminaire. You must provide a 
minimum clearance around your LEVANTE to allow for cooling.

The LEVANTE can be installed in a ground pit or any other confined 
enclosure only under certain conditions. With this kind of installation, a 
system of forced ventilation should be used up to allow air to circulate 
freely around the luminaire(s). The air must be constantly renewed 
because the luminaire cannot be operated in closed system. Failure to 
comply with these requirements may destroy or prematurely wear the 
LEVANTE, and AYRTON cannot be held responsible. Please consult your 
AYRTON dealer for more information on this type of installation.

No load should be placed on the LEVANTE. The fixture must not be 
installed in such a way as to allow a person, vehicle or any object to run 
over or park on it.

Never lay or drop any hard, heavy, or blunt, objects on the LEVANTE. This 
includes items made of glass or porcelain (e.g., bottles, dishware, or glass 
beads). The luminaire is made of materials such as plastic and extruded 
aluminum, making it resistant but not unbreakable. Objects made of hard 
materials such as steel or glass that fall on the unit may cause breakage 
of the plastic parts or the body. AYRTON cannot be held responsible for 
the luminaire’s broken plastic parts or body, which are not covered under 
warranty.

The temperature of the room where the LEVANTE is installed must never 
exceed 45°C (Ta = 45°C).

The LEVANTE luminaire requires a 110-240 VAC supply voltage. Check 
that your luminaires have been installed for an application that is 
compatible with this information.

Check that the brackets on which you hang or attach your LEVANTE can 
sustain the weight of the luminaire (21,8 kg), taking into consideration all 

necessary safety factors.

Do not use your LEVANTE before being familiar with these recommendations 
and do not allow unqualified personnel to handle the product.

To transport your LEVANTE, we strongly recommend that you use the 
complete original packaging, including the dense protective foam inserts.

If your LEVANTE is not being used for a long period, you should disconnect 
the luminaire from the power source.

Never dispose of the LEVANTE in a rubbish bin. Ensure that it is recycled. 
Please consult the current legislation in your country on recycling 
electronic equipment.

PRESENTATION AND FEATURES

LEVANTE is a non-waterproof moving head wash light (IP20 protection 
rating) using the latest generation of high-performance of LED-type lamps.

This luminaire can be controlled remotely by an external DMX512 signal.

The LEVANTE incorporates high power white LED source.

The luminaire requires from 29 to 50 DMX channels to be controlled via 
an external command system that sends a DMX512 signal (see below for 
details).

To adjust the settings on the LEVANTE (i.e., DMX address, DMX operating 
mode and other options), a Remote Device Management (RDM)-type DMX 
controller may be required. The DMX RDM protocol is a universal, widely 
used standard.

There are a multitude of RDM DMX controllers on the market from different 
manufacturers (excluding AYRTON). It is worth noting that an RDM DMX 
controller is not required to change the settings on the LEVANTE. A light 
console or any standard DMX-type controller is sufficient.

The LEVANTE consists of a metal frame and plastic covers. The power 
connectors and DMX512 signal connectors are on the back of the fixture’s 
base. 
 

 

Содержание AYRLEV101

Страница 1: ...USER MANUAL V 1 ENGLISH VERSION 02 2019...

Страница 2: ......

Страница 3: ...Description Installation instructions Installation method using truss hooks DMX512 connection Control Panel Ghibli control panel menu Option details Master Slave Mode settings DMX Chart Error Messages...

Страница 4: ...tandards In all cases make sure that the power cables attached to your LEVANTE have not been damaged due to cuts and splices or crushed in any way Handle these cables with extreme caution while they a...

Страница 5: ...f materials such as plastic and extruded aluminum making it resistant but not unbreakable Objects made of hard materials such as steel or glass that fall on the unit may cause breakage of the plastic...

Страница 6: ...USER MANUAL _ 6 DIMENSIONS Bottom view 107MM 147 5MM 107MM Front view 345 3MM 230MM 81 1MM 364 9MM Side view 476 6MM 97 5MM 460MM 631 6MM 82 6MM 210 6MM...

Страница 7: ...or must ensure that a qualified technician has approved the installation of the luminaire for safety before it is first operated Installation should be inspected once a year by a qualified technician...

Страница 8: ...ale XLR input connector with a 120 Ohm resistor is soldered between pins 2 and 3 This plug must be connected to the DMX output of the last luminaire in the chain Refer to the following diagram THE LEV...

Страница 9: ...X DMX WDMX Temp C F Celsius Fahrenheit Temperature C F Initial Pos PAN XXX Initial effect position Wireless DMX Activate WDMX Act Data Out Rest WDMX Activate WDMX Act Data Out Rest WDMX Dim Curve Squa...

Страница 10: ...ain Pan Reverse Reverses the PAN movement w w Double click jog wheel to access main menu w w Turn the jog wheel clockwise to display Options w w Double click to access Options turn the jog wheel to se...

Страница 11: ...ouble click to confirm w w Double click the jog wheel to back to last button press Fans Control then back to main menu by double click again DISP SETTING Shut off Time Allows the fixture s LCD display...

Страница 12: ...lick to access Options urn the jog wheel to select Trigger w w Double click to access Trigger menu The display will show DMX Value Disp w w Double click to access DMX Value Disp The display will show...

Страница 13: ...e display will show XXX C F w w Double click the jog wheel to back to last button press Temp Info then back to main menu by double click again SOFTWARE VER Displays the software version of the fixture...

Страница 14: ...ons to select Auto Program Press ENTER to confirm Use the buttons to select Master or Alone Master sets the fixture as the master Press ENTER to confirm Press MODE ESC to return to the main menu 3 Pro...

Страница 15: ...t Fine 12 10 14 Focus 0 255 Continuous adjustment from near to far 15 Focus Fine 0 255 Continuous adjustment Fine DMX channel s functions and their values 50DMX channels Mode Channel Value Function St...

Страница 16: ...trol mode 35 39 Studio fan control mode 40 44 Silent fan control mode 45 49 Square Law 50 54 Linear 55 59 1 2K 60 64 2 4K 65 69 16K 70 74 Gobo correction Off 75 79 Gobo correction On 80 84 All motor r...

Страница 17: ...e fixture with a slightly damp soft cloth When necessary use a non alcohol based glass cleaner Never use harsh solvents WARNING Never use alcohol or any chemical agent to clean the optical system of a...

Страница 18: ...ASE LEVANTE is delivered in a carton packed with a dense protective foam surrounding the fixture This reusable protective shell is intended for a flight case that can be custom built for the luminaire...

Страница 19: ...USER MANUAL _ 19...

Страница 20: ...www ayrton eu...

Отзывы: