Installation Precaution

Warning:

● Observe all governing codes and ordinances.

● Do not use damaged or non-standard power cord.

● Be caution during installation and maintenance. Prohibit incorrect operation 

   to prevent electric shock, casualty and other accidents.

Selection of Installation Location

Requirements Forelectric Connection

Basic requirement

Installing the unit in the following places may cause malfunction. If it is unavoidable, please 

consult the local dealer:

    objects spread in the air.

2. The place with high-frequency devices (such as welding machine, medical equipment).

3. The place near coast area.

4. The place with oil or fumes in the air.

5. The place with sulfureted gas.

6. Other places with special circumstances.

Requirement of air conditioner

1. Air inlet should be far away from obstacles and do not put any objects near air outlet. 

    Otherwise, it will affect the radiation of heat-removal pipe.

2. Select a location where the noise and outflow air emitted by the outddor unit will not affect 

    neighborood.

3. Please try your best to keep far away from fluorescent lamp.

4.The appliance shall not be installed in the laundry.

Safety precaution

1. Must follow the electric safety regulations when installing the unit.

2. According to the local safety regulations, use qualified power supply circuit.

3. For appliances with type Y attachment,the instructions shall contain the substance of 

    the following.If the supply cord is damaged,it must be replaced by the manufacturer, its 

    service agent or similarly qualified persons in order to avoid a hazard.

4. Properly connect the live wire, neutral wire and grounding wire of power socket.

5. Be sure to cut off the power supply before proceeding any work related to electricity and 

    safety.

6. Do not put through the power before finishing installation.

7. The air conditioner is first class electric appliance. It must be properly grounding with 

    specialized grounding device by a professional. Please make sure it is always grounded 

    effectively, otherwise it may cause electric shock.

8. The yellow-green wire or green wire in air conditioner is grounding wire, which can't be 

    used for other purposes.

9. The grounding resistance should comply with national electric safety regulations.

10. The appliance shall be installed in accordance with national wiring regulations.

Содержание AYM-07

Страница 1: ...USER MANUAL AYM 07...

Страница 2: ...less they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure they are away from the appliance D...

Страница 3: ...combination buttons 8 Operation guide 8 Replacement of batteries in remote controller 9 Maintenance Clean and Maintenance 10 Malfunction Malfunction analysis 12 Installation Notice Installation Precau...

Страница 4: ...o not pull or drag the power cord to pull out the power plug or move the air conditioner Do not insert or pull out the power plug with wet hands Please use the grounded power Make sure the gounding is...

Страница 5: ...be discarded Note 1 2 3 4 5 12 13 11 10 9 6 7 8 Remote controller 1 Controller panel 2 Guide louver 3 Swing louver 4 Wheel 5 Remote controller box 6 Power cord 7 Filters 8 Upper air inlet grille 9 Low...

Страница 6: ...ressing of the button on control panel the air conditioner will give out a sound Meanwhile corresponding indicator on control panelwill be bright Under OFF status dual 8 nixie tube on control panel wo...

Страница 7: ...RY Under this mode drying mode indicator is bright Dual 8 nixie tube won t be display FAN Under this mode the air conditioner only blow fan Fan indicator is bright Dual 8 nixie tube won t be display M...

Страница 8: ...6 7 1 3 5 2 4 6 7 ON OFF button MODE button button FAN button SWING button SLEEP button TIMER button Timer on Timer off Sending signal swing operation sleep operation lock set speed Set time Set temp...

Страница 9: ...adjusted and won t be displayed either Press FAN button to adjust fan speed When selecting cool mode air conditioner will operate under cool mode Then press or button to adjust set temperature Press...

Страница 10: ...n T ON and H icon will be blinking Within 5s press or button to adjust the time for Timer On Pressing or button once will increase or decrease the time by 0 5h or 1h Hold or button for 2s time will ch...

Страница 11: ...n When child lock function is started up LOCK indicator on remote controller is ON If you operate the remote controller remote controller won t send signal Child lock function Temperature display swit...

Страница 12: ...be close to indoor unit during operation Replace new batteries of the same model when replacement is required When you don t use remote controller for a long time please take out the batteries If the...

Страница 13: ...ry dirty such as grease please use neutral abluent to wipe it Clean outer case and grille Clean grille Use cleaner or soft brush to clean it Clean filter Note 1 3 2 Remove the filter Install filter Cl...

Страница 14: ...on 1 Disconnect power supply 2 Clean filter and outer case 3 Remove dust and sundries on the air conditioner 4 Eliminate accumulated water in chassis refer to the section of Drainage way for details 5...

Страница 15: ...Whether the set temperature is proper Whether door and window are closed Is plug loose Whether the air switch is trip ped off or fuse is burnt Is there s malfunction for the circuit Whether the unit...

Страница 16: ...r a while to be started up which is the normal phenomenon It s the normal phenomenon Air conditioner is defrosting After defrosting is finished it will resume operation No fan blowed out from air cond...

Страница 17: ...Pour out the water inside chassis 2 If H8 still exits please contact Please contact previsional person Please contact previsional person to deal with it to deal with it professional person to maintain...

Страница 18: ...from fluorescent lamp 4 The appliance shall not be installed in the laundry Safety precaution 1 Must follow the electric safety regulations when installing the unit 2 According to the local safety re...

Страница 19: ...ore installation Accessory list Tools needed for installation unit joint A joint B joint C heat discharge pipe drainage pipe cross screwdriver gauge straight screwdriver scissors saw pencil remote con...

Страница 20: ...ht of rear side plate near drainage port with a screw 3 Put the drainage pipe into drainage port and screw it up and then bind it with pipe hoop 4 Put the rubber plug into the other side of drainage p...

Страница 21: ...int A joint B joint B joint C heat discharge pipe 2 Insert joint A of heat discharge pipe the side with TOP is upwards into the groove until you hear a sound 3 Aim the locating pole of joint B of heat...

Страница 22: ...harge pipe should be as short as possible and flat without curve to ensure smooth heat discharge correct correct correct wrong The length of the exhaust pipe is less than 1m It is recommended to use i...

Страница 23: ...t joint B joint C upwards clasp disassemble joint A Correct installation is as shown in figure When installing it on wall height of hall should be about 40cm 130cm from floor Wrong installation is sho...

Страница 24: ...d drained to outdoor So usually only a little condensation water will be accumulated inside the chassis and you do not need to discharge the water frequently When the chassis is full with water the bu...

Страница 25: ...L BN BK N YEGN GN BU WH BU N3 W5 S COMP YEGN C 2 1 W3 YE C1 K201 L 3 COMP 4 R M AP1 N1 WATER WATER1 DISP2 W2 RD FAN W4 RD YE BK WH BU DISP1 MOTOR COMP W1 BU SA NC COM WH BK HIGH WP W6 W7 RD DISP2 ROOM...